High Rate of Ceramic Sandwich Liner Fracture
Authors:
- Ronny LopesRLRonny Lopes
- Jean M. PhilippeauJPJean M. Philippeau
- Norbert PassutiNPNorbert Passuti
- François GouinFGFrançois Gouin
- 1 June 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (6) , 1705-1710
Abstract
Tural rigidity was introduced. Fractures of these devices also were reported subsequently, although the incidence is unclear and it is unknown whether there are any risk factors associated with the fractures. Questions/purposes We therefore determined the incidence of these fractures. Methods We retrospectively reviewed 298 active patients in whom we implanted 353 ceramic-polyethylene sandwich liner acetabular components between November 1999 and February 2008. The mean age of the patients was 53.6 years (range, 17-84 years). The minimum followup was 6 months (mean, 41 months; range, 6-106 months). All patients were assessed clinically and radiographically. Results Seven of the 353 (2%) ceramic sandwich liners fractured at a mean of 4.3 years (range, 1.3-7.6 years) after surgery without trauma. Neither patient-related factors nor radiographic position of the implants were risk factors for fracture. Conclusions Owing to the high rate of fractures of the sandwich ceramic polyethylene liners in our patients, we have discontinued use of this device. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....Keywords
This publication has 18 references indexed in Scilit:
- Ten-Year Results After Cementless THA with a Sandwich-Type Alumina Ceramic BearingOrthopedics, 2010
- Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic BearingJournal of Bone and Joint Surgery, 2010
- Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosisInternational Orthopaedics, 2009
- Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cupArchives of orthopaedic and trauma surgery, 2007
- Failure Analysis of a Ceramic Bearing Acetabular ComponentJournal of Bone and Joint Surgery, 2007
- Cementless Alumina-on-Alumina Total Hip Arthroplasty in Patients Younger Than 50 Years: A 5-year Minimum Follow-Up StudyThe Journal of Arthroplasty, 2007
- Alumina ceramic-on-ceramic total hip replacement with a layered acetabular componentThe Journal of Bone and Joint Surgery. British volume, 2006
- Ceramic Failure After Total Hip Arthroplasty with an Alumina-on-Alumina BearingJournal of Bone and Joint Surgery, 2006
- Concerns about Ceramics in THAClinical Orthopaedics and Related Research, 2004
- Three-dimensional polyethylene wear of a press-fit titanium prosthesisThe Journal of Arthroplasty, 1997