Fluorescent immunoconjugates prepared with the europium chelate BHHCT (4,4′‐bis(1″,1″,1″,2″,2″,3″,3″‐heptafluoro‐4″,6″‐hexanedion‐6″‐yl)‐chlorosulfo‐o‐terphenyl) have previously been reported as suitable labels for time‐resolved fluorescence applications. BHHCT is limited by a tendency to destabilize immunoglobulins when covalently bound to the protein at moderate to high fluorophore to protein ratios (F/P). We report a new derivative of BHHCT prepared by appending a short hydrophylic tether to the chlorosulfonate activating group on BHHCT. The new derivative, BHHST (4,4′‐bis‐(1″,1″,1″,2″,2″,3″,3″‐heptafluoro‐4″,6″‐hexanedion‐6″‐yl)sulfonylamino‐propyl‐ester‐N‐succinimide‐ester‐o‐terphenyl), was activated to bind at the tether terminus with a succinimide leaving group that displayed less aggressive coupling activity and improved storage stability. BHHST has been used to prepare a stable and useful immunoconjugate with the anti‐Cryptosporidium monoclonal antibody CRY104. The BHHST immunoconjugate provides more than a 10‐fold enhancement in the signal to noise ratio (SNR) of labeled oocyst fluorescence over background when observed using TRFM techniques. An immunoconjugate was also prepared with BHHST and (goat) anti‐mouse that effectively labeled Giardia cysts in situ. Detection of cysts with the TRFM was achieved with an 11‐fold increase in SNR when a gate‐delay of 60 μs was employed. The storage half‐life of both immunoconjugates is extended more than 20‐fold when compared to immunoconjugates prepared with BHHCT. Microsc. Res. Tech. 64:312–322, 2004.Keywords
This publication has 28 references indexed in Scilit:
- Flash lamp-excited time-resolved fluorescence microscope suppresses autofluorescence in water concentrates to deliver an 11-fold increase in signal-to-noise ratioJournal of Biomedical Optics, 2004
- Targeting Cells That Overexpress the Epidermal Growth Factor Receptor with Polyethylene Glycolated BPD Verteporfin Photosensitizer Immunoconjugates¶Photochemistry and Photobiology, 2003
- High resolution detection of fluorescently labeled microorganisms in environmental samples using time-resolved fluorescence microscopyFEMS Microbiology Ecology, 2002
- A New Tetradentate β-Diketonate−Europium Chelate That Can Be Covalently Bound to Proteins for Time-Resolved FluoroimmunoassayAnalytical Chemistry, 1998
- Influence of Coupling Method on the Luminescence Properties, Coupling Efficiency, and Binding Affinity of Antibodies Labeled with Europium(III) ChelatesBioconjugate Chemistry, 1997
- Synthesis of a New Tetradentate ß-Diketonate-Europium Chelate That Can Be Covalently Bound to Proteins in Time-Resolved FluorometryAnalytical Sciences, 1996
- The use of peroxidase-mediated deposition of biotin-tyramide in combination with time-resolved fluorescence imaging of europium chelate label in immunohistochemistry and in situ hybridization.Journal of Histochemistry & Cytochemistry, 1996
- Luminescent Polyaminocarboxylate Chelates of Terbium and Europium: The Effect of Chelate StructureJournal of the American Chemical Society, 1995
- A new method for the concentration of Cryptosporidium oocysts from waterJournal of Applied Bacteriology, 1993
- Multiple fluorescence labeling with europium chelators. Application to time-resolved fluoroimmunoassaysAnalytical Chemistry, 1989