RCRussell Connally

Russell Connally

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Russell Connally has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • James A. Piper

    Advanced Cytometry Laboratories, ARC Centre of Excellence for Nanoscale BioPhotonics (CNBP), Macquarie University, Sydney, New South Wales 2109, Australia

    6 shared publications
  • Duncan Veal

    Department of Biological Sciences, Division of Environmental and Life Sciences, Macquarie University, Sydney, NSW 2109, Australia

    3 shared publications
  • Dayong Jin

    Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sydney, Australia

    1 shared publication

Latest Publications

  • Time‐Gated Luminescence Microscopy

    by Russell E. Connally, James A. Piper

    Autofluorescent algal samples were spiked with europium beads for analysis on a novel all‐solid‐state, time‐gated luminescence (TGL) microscope. Pulsed UV excitation (365 nm) was provided by a high‐power UV‐LED source fitted to an Olympus BX51 microscope. An “Impactron” electron multiplying charge‐coupled‐device (CCD) camera acquired images in delayed luminescence mode. Second, we evaluated sensitivity of the instrument by acquiring images of immunofluorescently labeled Giardia cysts with a single‐exposure period of 3 ms. The camera was triggered 3 μs after the LED had extinguished to yield a 14‐fold increase in signal‐to‐noise ratio within a single 33 ms capture cycle. This novel instrument could be switched instantly from prompt epifluorescence mode to TGL mode for suppression of short‐lived fluorescence.


  • Open Access

    Solid-state time-gated luminescence microscope with ultraviolet light-emitting diode excitation and electron-multiplying charge-coupled device detection

    by Russell Connally, James Piper

    Many naturally occurring materials are autofluorescent, a property that can reduce the discriminative ability of fluorescence methods, sometimes to the point where they cannot be usefully applied. Shifting from the spectral to the temporal domain, it is possible to discriminate fluorophores on the basis of their fluorescence decay lifetime. Luminophores with sufficiently long lifetimes can be discriminated from short-lived autofluorescence using time-gated luminescence (TGL). This technique relies upon the application of a brief excitation pulse followed by a resolving period to permit short-lived autofluorescence to decay, after which detection is enabled to capture persistent emission. In our studies, a high-power UV LED was mounted in the filter capsule of an Olympus BX51 microscope to serve as the excitation source. The microscope was fitted with an Andor DV885 electron-multiplying CCD (EM-CCD) camera with the trigger input synchronized to UV LED operation. Giardia lamblia cysts labeled with the europium chelate BHHST were analyzed against an autofluorescent background with the TGL microscope. The EM-CCD camera captured useful TGL images in real time with a single exposure cycle. With 4x frame averaging, images acquired in TGL mode showed a 30-fold improvement in SNR compared with conventional fluorescence microscopy.


  • Open Access

    High intensity solid‐state UV source for time‐gated luminescence microscopy

    by Russell Connally, Dayong Jin, James Piper

    Background.: The unique discriminative ability of immunofluorescent probes can be severely compromised when probe emission competes against naturally occurring, intrinsically fluorescent substances (autofluorophores). Luminescence microscopes that operate in the time‐domain can selectively resolve probes with long fluorescence lifetimes (τ > 100 μs) against short‐lived fluorescence to deliver greatly improved signal‐to‐noise ratio (SNR). A novel time‐gated luminescence microscope design is reported that employs an ultraviolet (UV) light emitting diode (LED) to excite fluorescence from a europium chelate immunoconjugate with a long fluorescence lifetime.Methods.: A commercial Zeiss epifluorescence microscope was adapted for TGL operation by fitting with a time‐gated image‐intensified CCD camera and a high‐power (100 mW) UV LED. Capture of the luminescence was delayed for a precise interval following excitation so that autofluorescence was suppressed. Giardia cysts were labeled in situ with antibody conjugated to a europium chelate (BHHST) with a fluorescence lifetime >500 μs.Results.: BHHST‐labeled Giardia cysts emit at 617 nm when excited in the UV and were difficult to locate within the matrix of fluorescent algae using conventional fluorescence microscopy, and the SNR of probe to autofluorescent background was 0.51:1. However in time‐gated luminescence mode with a gate‐delay of 5 μs, the SNR was improved to 12.8:1, a 25‐fold improvement.Conclusion.: In comparison to xenon flashlamps, UV LEDs are inexpensive, easily powered, and extinguish quickly. Furthermore, the spiked emission of the LED enabled removal of spectral filters from the microscope to significantly improve efficiency of fluorescence excitation and capture. © 2006 International Society for Analytical Cytology


  • Time‐resolved fluorescence microscopy using an improved europium chelate BHHST for the in situ detection of Cryptosporidium and Giardia

    by Russell Connally, Duncan Veal, James Piper

    Fluorescent immunoconjugates prepared with the europium chelate BHHCT (4,4′‐bis(1″,1″,1″,2″,2″,3″,3″‐heptafluoro‐4″,6″‐hexanedion‐6″‐yl)‐chlorosulfo‐o‐terphenyl) have previously been reported as suitable labels for time‐resolved fluorescence applications. BHHCT is limited by a tendency to destabilize immunoglobulins when covalently bound to the protein at moderate to high fluorophore to protein ratios (F/P). We report a new derivative of BHHCT prepared by appending a short hydrophylic tether to the chlorosulfonate activating group on BHHCT. The new derivative, BHHST (4,4′‐bis‐(1″,1″,1″,2″,2″,3″,3″‐heptafluoro‐4″,6″‐hexanedion‐6″‐yl)sulfonylamino‐propyl‐ester‐N‐succinimide‐ester‐o‐terphenyl), was activated to bind at the tether terminus with a succinimide leaving group that displayed less aggressive coupling activity and improved storage stability. BHHST has been used to prepare a stable and useful immunoconjugate with the anti‐Cryptosporidium monoclonal antibody CRY104. The BHHST immunoconjugate provides more than a 10‐fold enhancement in the signal to noise ratio (SNR) of labeled oocyst fluorescence over background when observed using TRFM techniques. An immunoconjugate was also prepared with BHHST and (goat) anti‐mouse that effectively labeled Giardia cysts in situ. Detection of cysts with the TRFM was achieved with an 11‐fold increase in SNR when a gate‐delay of 60 μs was employed. The storage half‐life of both immunoconjugates is extended more than 20‐fold when compared to immunoconjugates prepared with BHHCT. Microsc. Res. Tech. 64:312–322, 2004.


  • Flash lamp-excited time-resolved fluorescence microscope suppresses autofluorescence in water concentrates to deliver an 11-fold increase in signal-to-noise ratio

    by Russell Connally, Duncan Veal, James Piper

    The ubiquity of naturally fluorescing components (autofluorophores) encountered in most biological samples hinders the detection and identification of labeled targets through fluorescence-based techniques. Time-resolved fluorescence (TRF) is a technique by which the effects of autofluorescence are reduced by using specific fluorescent labels with long fluorescence lifetimes (compared with autofluorophores) in conjunction with time-gated detection. A time-resolved fluorescence microscope (TRFM) is described that is based on a standard epifluorescence microscope modified by the addition of a pulsed excitation source and an image-intensified time-gateable CCD camera. The choice of pulsed excitation source for TRFM has a large impact on the price and performance of the instrument. A flash lamp with rapid discharge characteristics was selected for our instrument because of the high spectral energy in the UV region and short pulse length. However, the flash output decayed with an approximate lifetime of 18 μs and the TRFM required a long-lived lanthanide chelate label to ensure that probe fluorescence was visible after decay of the flash plasma. We synthesized a recently reported fluorescent chelate (BHHCT) and conjugated it to a monoclonal antibody directed against the waterborne parasite Giardia lamblia. For a 600-nm bandpass filter set and a gate delay of 60 μs, the TRFM provided an 11.3-fold improvement in the signal-to-noise ratio (S/N) of labeled Giardia over background. A smaller gain in an SNR of 9.69-fold was achieved with a 420-nm longpass filter set; however, the final contrast ratio between labeled cyst and background was higher (11.3 versus 8.5). Despite the decay characteristics of the light pulse, flash lamps have many practical advantages compared with optical chopper wheels and modulated lasers for applications in TRFM. © 2004 Society of Photo-Optical Instrumentation Engineers.


  • Open Access

    High resolution detection of fluorescently labeled microorganisms in environmental samples using time-resolved fluorescence microscopy

    by Russell Connally, Duncan Veal, James Piper

    The high level of discrimination offered by fluorescence microscopy has led to its widespread use for the analysis of individual microbial cells. The major limitation of fluorescence microscopy in microbial ecology is that many types of environmental samples contain autofluorescent material that can obscure emission from a fluorescent label. Time-resolved fluorescence microscopy (TRFM) is a technique that greatly reduces background autofluorescence whilst maintaining signal strength of the fluorescent target. TRFM differs from fluorescent microscopy in the use of fluorophores that are characterized by long-lived luminescence. Samples are briefly illuminated to excite fluorescence then capture of luminescence is delayed for a time interval sufficient to ensure autofluorescence has largely faded. TRFM has not been extensively used in microbiology because of the limitations and cost of available time-resolved microscopes and the lack of suitable long-lived fluorescent labels. Here we describe modification of a commercial fluorescence microscope for time-resolved operation through the addition of an image-intensified camera and low cost flashlamp. The TRFM was used in combination with a novel immunofluorophore for the specific detection of Giardia cysts in a water sample containing large amounts of autofluorescent material. A 60-μs gate delay between excitation and detection resulted in a 30-fold increase in contrast of labeled parasites compared to conventional immunostaining. To our knowledge, this is the first report of the use of TRFM for the detection of microorganisms in environmental samples.