Practical application of Westgard Sigma rules with run size in analytical biochemistry processes in clinical settings
Open Access
- 3 December 2020
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (3) , e23665
Abstract
Background: The performance of 18 routine chemical detection methods was evaluated by the sigma (σ) metric, and Westgard Sigma rules with run size were used to establish internal quality control (IQC) standards to reduce patient risks.Materials and methods: External quality assessment (EQA) and internal quality control data from 18 assays in a biochemical laboratory were collected from January to June 2020. The sigma values of each assay were calculated, based on the bias, total error allowable, and coefficient of variation, appropriate quality control rules were selected. According to the quality goal index, the main causes of poor performance were determined to guide quality improvement.Results: At IQC material level 1, seven of the 18 assays achieved five sigma (excellent), and five assays (UA, Crea, AMY, TC and Na) showed world‐class performance. At IQC material level 2, 14 of the 18 assays achieved 5 sigma (excellent), and thirteen assays (UA, ALT, CK, Crea, AMY, K, AST, ALP, Na, LDH, Mg, TC and GGT) showed world‐class performance. The quality goal index (QGI) was calculated for items with analysis performance <5 sigma, and the main causes of poor performance were determined to guide quality improvement.Conclusions: Westgard sigma rules with run size are an effective tool for evaluating the performance of biochemical assays. These rules can be used to more simply and intuitively select the quality control strategy of related items and reduce the risk to patients.Keywords
This publication has 18 references indexed in Scilit:
- Evaluation of Preanalytical Quality Indicators by Six Sigma and Pareto`s PrincipleIndian Journal of Clinical Biochemistry, 2017
- Practical application of biological variation and Sigma metrics quality models to evaluate 20 chemistry analytes on the Beckman Coulter AU680Clinical Biochemistry, 2016
- Analytical performance evaluation of a high‐volume hematology laboratory utilizing sigma metrics as standard of excellenceInternational Journal of Laboratory Hematology, 2016
- Quality control review: implementing a scientifically based quality control systemAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2015
- Multiplex Polymerase Chain Reaction Tests for Detection of Pathogens Associated with GastroenteritisClinics In Laboratory Medicine, 2015
- Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) targetClinical Chemistry and Laboratory Medicine (CCLM), 2014
- Quantitative Application of Sigma Metrics in Medical BiochemistryJournal of Clinical and Diagnostic Research, 2013
- Application of Sigma Metrics for the Assessment of Quality Assurance in Clinical Biochemistry Laboratory in India: A Pilot StudyIndian Journal of Clinical Biochemistry, 2010
- The quality of laboratory testing today: an assessment of sigma metrics for analytic quality using performance data from proficiency testing surveys and the CLIA criteria for acceptable performance.2006
- The Quality of Laboratory Testing TodayAmerican Journal of Clinical Pathology, 2006