JZJinFei Zhang

JinFei Zhang

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


JinFei Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Usefulness of International Normalized Ratio to Albumin Ratio for Evaluation of Mortality in Hepatitis B Virus‐Associated Decompensated Cirrhosis

    by Ming Cai, Zhong Han, Xia He, JinFei Zhang

    Background. We sought to determine the prognostic value of prothrombin time‐international normalized ratio to albumin ratio (PTAR) in patients with hepatitis B virus‐associated decompensated cirrhosis (HBV‐DeCi). Methods. The study enrolled 166 HBV‐DeCi patients. Multivariate regression analysis was performed to identify predictors associated with mortality. Results. Among the 166 HBV‐DeCi patients, 27 (16.3%) had died by 30 days after admission. PTAR was markedly increased in nonsurvivors compared with survivors, and had a significant positive correlation with disease severity. Multivariate analysis identified PTAR as an effective independent predictor for mortality in HBV‐DeCi patients. Conclusions. High PTAR was associated with poor outcomes and can act as a novel prognostic predictor for mortality in HBV‐DeCi patients.


  • Open Access

    Practical application of Westgard Sigma rules with run size in analytical biochemistry processes in clinical settings

    by SongQing Peng, JinFei Zhang, WuQiong Zhou, WeiLin Mao, Zhong Han

    Background: The performance of 18 routine chemical detection methods was evaluated by the sigma (σ) metric, and Westgard Sigma rules with run size were used to establish internal quality control (IQC) standards to reduce patient risks.Materials and methods: External quality assessment (EQA) and internal quality control data from 18 assays in a biochemical laboratory were collected from January to June 2020. The sigma values of each assay were calculated, based on the bias, total error allowable, and coefficient of variation, appropriate quality control rules were selected. According to the quality goal index, the main causes of poor performance were determined to guide quality improvement.Results: At IQC material level 1, seven of the 18 assays achieved five sigma (excellent), and five assays (UA, Crea, AMY, TC and Na) showed world‐class performance. At IQC material level 2, 14 of the 18 assays achieved 5 sigma (excellent), and thirteen assays (UA, ALT, CK, Crea, AMY, K, AST, ALP, Na, LDH, Mg, TC and GGT) showed world‐class performance. The quality goal index (QGI) was calculated for items with analysis performance <5 sigma, and the main causes of poor performance were determined to guide quality improvement.Conclusions: Westgard sigma rules with run size are an effective tool for evaluating the performance of biochemical assays. These rules can be used to more simply and intuitively select the quality control strategy of related items and reduce the risk to patients.