Impact of tool design on defect detection sensitivity in extreme ultraviolet actinic blank inspection
- 1 April 2017
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Micro/Nanolithography, MEMS, and MOEMS
- Vol. 16 (2) , 023502
Abstract
We discuss the impact of various tool design perspectives on defect detection sensitivity for dark-field-based extreme ultraviolet (EUV) actinic blank inspection. We consider the impact of pixel size, EUV source type, and photon collection efficiency on critical defect signal-to-noise ratio (SNR) performance. The results show that as the pixel size approaches the target defect image size, defect SNR increases, and that pixel size also determines the dominant noise source in the inspection system. Moreover, the choice of the EUV source affects the optimal numerical aperture (NA) and illumination settings. For plasma-discharged sources, more photons provided by larger partial coherent illumination can improve the defect SNR, while coherent illumination is needed to get a higher defect SNR for synchrotron-based source. In the end, we show that simply increasing the photon collection efficiency by using high-NA optics or increasing the source power cannot always improve the defect SNR. In a speckle-noise dominated situation, larger outer NA includes more noise than defect signal, thus resulting in a lower SNR. The impact of source power also saturates at a certain level as the system becomes speckle-noise limited compared to photon-noise limited.Keywords
Funding Information
- Center for Design-Enabled Nanofabrication
- U.S. Department of Energy (DE-AC02-05CH11231)
- U.S. Department of Energy (DE-AC02-05CH11231)
- Office of Science (DE-AC02-05CH11231)
- U.S. Department of Energy (DE-AC02-05CH11231)
- U.S. Department of Energy by the University of California Lawrence Berkeley National Laboratory (DE-AC02-05CH11231)
- Director, Office of Science, Office of Basic Energy Sciences, Material Science Division, of the U.S. Department of Energy (DE-AC02-05CH11231)
- Lawrence Berkeley National Laboratory (DE-AC02-05CH11231)
This publication has 9 references indexed in Scilit:
- RESCAN: an actinic lensless microscope for defect inspection of EUV reticles2017
- Impact of noise sources and optical design on defect detection sensitivity in extreme ultraviolet actinic pattern inspection toolJournal of Micro/Nanolithography, MEMS, and MOEMS, 2017
- EUV mask infrastructure readiness and gaps for TD and HVM2015
- Understanding EUV mask blank surface roughness induced LWR and associated roughness requirement2015
- Enhancing defect detection with Zernike phase contrast in EUV multilayer blank inspection2015
- Extreme ultraviolet mask roughness: requirements, characterization, and modeling2014
- Commissioning an EUV mask microscope for lithography generations reaching 8 nm2013
- Laser-produced plasma versus laser-assisted discharge plasma: physics and technology of extreme ultraviolet lithography light sourcesJournal of Micro/Nanolithography, MEMS, and MOEMS, 2012
- Development of actinic full-field EUV mask blank inspection tool at MIRAI-Selete2009