Postoperative early and proactive grip strength training program for distal radius fractures promotes earlier recovery of grip strength
Open Access
- 13 May 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (19) , e29262
Abstract
The use of volar locking plates (VLPs) for distal radius fractures has remarkably improved clinical outcomes; however, there are some reports of delayed recovery of grip strength. Since January 2019, we have been conducting an early and proactive grip strength training program (EGTP). In this program, 20 minutes of grip strength training—using a gripper with a load of 0.7 kg—was initiated from 2 weeks after surgery; the load was then gradually increased. From 6 weeks postsurgery, daily home grip strength training was performed using a gripper with a load of 5 kg, provided to the patient. We investigated whether the introduction of the EGTP could lead to earlier recovery of grip strength. We also examined whether the EGTP caused postoperative correction loss at the fractured site, or contributed to the early improvement of wrist function. Thirty-nine patients who underwent surgery using VLPs for distal radius fractures were included in this study; 20 followed the EGTP (EGTP group) and 19 patients did not (NGTP group). For these patients, grip strength and range of motion of the wrist joint were evaluated both 3 and 6 months postoperatively. The Quick Disabilities of the Arm, Shoulder, and Hand (qDASH) scores were also evaluated 6 months postoperatively. Additionally, corrective losses of radial inclination (RI), palmar tilt (PT), and ulnar variance (UV)—occurring from immediately postsurgery to 6 months after surgery—were evaluated. At both 3 and 6 months postoperatively, the grip strength of the EGTP group was significantly higher than that of the NGTP group. Regarding range of motion, only palmar flexion was significantly improved in the EGTP group at 3 months postoperatively. Conversely, no differences in corrective losses of RI, PT, and UV, or in qDASH scores, were observed between the two groups. The results of this study suggest that the EGTP can provide early recovery of grip strength and palmar flexion of the wrist without causing corrective loss at the fracture site.Keywords
This publication has 34 references indexed in Scilit:
- Differences in Measurement of Lower Limb Alignment Among Different Registration Methods of Navigation and Radiographs in TKA Using the OrthoPilot SystemOrthopedics, 2012
- Evaluation of Factors Influencing Grip Strength in Elderly KoreansJournal of Bone Metabolism, 2012
- A Prospective Randomized Trial Comparing Nonoperative Treatment with Volar Locking Plate Fixation for Displaced and Unstable Distal Radial Fractures in Patients Sixty-five Years of Age and OlderOrthopedics, 2012
- Restoration of Voluntary Muscle Strength After 3 Weeks of Cast Immobilization is Suppressed in Women Compared With MenArchives of Physical Medicine and Rehabilitation, 2009
- Prospective Study of Distal Radius Fractures Treated With a Volar Locking Plate SystemThe Journal of Hand Surgery, 2008
- External Fixation of Distal Radius FracturesThe Journal of Hand Surgery, 2007
- Activities and impairments in the early stage of rehabilitation after Colles' fractureDisability and Rehabilitation, 2004
- Association between objective clinical variables and patient-rated disability of the wristThe Journal of Bone and Joint Surgery. British volume, 2002
- The role of physiotherapy and clinical predictors of outcome after fracture of the distal radiusThe Journal of Bone and Joint Surgery. British volume, 2000
- L'embrochage intra-focal des fractures de l'extrémité inférieure du radius dix ans aprèsAnnales de Chirurgie de la Main, 1987