Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study (Preprint)
Authors:
- Hope Davis-WilsonHDHope Davis-Wilson
- Meghan Hegarty-CraverMeghan Hegarty-Craver
- Pooja GaurPGPooja Gaur
- Matthew BoyceMBMatthew Boyce
- Jonathan R HoltJHJonathan R Holt
- Edward PrebleEPEdward Preble
- Randall EckhoffRERandall Eckhoff
- Lei LiLLLei Li
- Howard WallsHWHoward Walls
- David DauschDDDavid Dausch
- Dorota TempleDTDorota Temple
Preprint
- 16 October 2023
- preprint
- Published by JMIR Publications Inc. in JMIR Preprints
Abstract
BACKGROUND Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors. OBJECTIVE This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings. METHODS Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor. RESULTS At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P<.001) were unstable at 10% data degradation. LF (rest: P<.001; activity: P<.001), HF (rest: P<.001, activity: P<.001), and LF/HF (rest: P<.001, activity: P<.001) were unstable at 10% data degradation during rest and activity. Median IBI values calculated from photoplethysmography sensors had a moderate agreement (intraclass correlation coefficient [ICC]=0.585) and consistency (ICC=0.589) and LF had moderate consistency (ICC=0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC=0.071-0.472). CONCLUSIONS This study describes a methodology for the extraction of HRV metrics from photoplethysmography sensor data that resulted in stable and valid metrics while using the least amount of available data. While smartwatches containing photoplethysmography sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.Keywords
All Related Versions
- Published version: JMIR Formative Research, 9 (1), e53645.
This publication has 30 references indexed in Scilit:
- Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn WearablesJournal of Medical Systems, 2017
- Autonomic Dysfunction after Mild Traumatic Brain InjuryBrain Sciences, 2017
- Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based SettingJournal of Strength & Conditioning Research, 2017
- Remote Monitoring to Reduce Heart Failure ReadmissionsCurrent Heart Failure Reports, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Fitting Linear Mixed-Effects Models Usinglme42015
- Home telemonitoring effectiveness in COPD: a systematic reviewInternational Journal Of Clinical Practice, 2014
- Impact of accelerometer wear time on physical activity data: a NHANES semisimulation data approachBritish Journal of Sports Medicine, 2012
- Statistical strategies to quantify respiratory sinus arrhythmia: Are commonly used metrics equivalent?Biological Psychology, 2012
- Heart rate variability: Standards of measurement, physiological interpretation, and clinical useEuropean Heart Journal, 1996