Howard J. Walls
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Howard J. Walls has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- David Edward Dausch
RTI International, Morrisville, NC, United States
6 shared publications - Hope C. Davis-Wilson
RTI International, Research Triangle Park, NC 27709, USA
6 shared publications - Meghan Hegarty-Craver
RTI International, Research Triangle Park, NC 27709, USA
6 shared publications - Pooja Gaur
RTI International, Morrisville, NC, United States
6 shared publications - Dorota Temple
RTI International, Morrisville, NC, United States
5 shared publications - Edward A. Preble
RTI International, Research Triangle Park, USA
5 shared publications
Latest Publications
- Open Access
- 24 February 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e53645
Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study
Background: Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors. Objective: This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings. Methods: Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor. Results: At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P<.001) were unstable at 10% data degradation. LF (rest: P<.001; activity: P<.001), HF (rest: P<.001, activity: P<.001), and LF/HF (rest: P<.001, activity: P<.001) were unstable at 10% data degradation during rest and activity. Median IBI values calculated from photoplethysmography sensors had a moderate agreement (intraclass correlation coefficient [ICC]=0.585) and consistency (ICC=0.589) and LF had moderate consistency (ICC=0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC=0.071-0.472). Conclusions: This study describes a methodology for the extraction of HRV metrics from photoplethysmography sensor data that resulted in stable and valid metrics while using the least amount of available data. While smartwatches containing photoplethysmography sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.
- 24 February 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e53645
Open AccessEffects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study
Background: Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors. Objective: This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings. Methods: Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor. Results: At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P<.001) were unstable at 10% data degradation. LF (rest: P<.001; activity: P<.001), HF (rest: P<.001, activity: P<.001), and LF/HF (rest: P<.001, activity: P<.001) were unstable at 10% data degradation during rest and activity. Median IBI values calculated from photoplethysmography sensors had a moderate agreement (intraclass correlation coefficient [ICC]=0.585) and consistency (ICC=0.589) and LF had moderate consistency (ICC=0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC=0.071-0.472). Conclusions: This study describes a methodology for the extraction of HRV metrics from photoplethysmography sensor data that resulted in stable and valid metrics while using the least amount of available data. While smartwatches containing photoplethysmography sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.
- Open Access
- 7 August 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e53977
Continuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study
Background: Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. Objective: In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. Methods: A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. Results: The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. Conclusions: We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- 7 August 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e53977
Open AccessContinuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study
Background: Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. Objective: In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. Methods: A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. Results: The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. Conclusions: We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- Open Access
- 15 February 2024
- Published by RTI Press
Wearable Sensors for Service Members and First Responders: Considerations for Using Commercially Available Sensors in Continuous Monitoring
Wearable sensors (“wearables”) provide a mechanism to monitor the health of service members and first responders continuously and remotely. Several wearables are commercially available, with different configurations, sensors, algorithms, and forms of communication. Choosing the “best” wearable depends on the information you need to make decisions, how often you need this information, and the level of accuracy required. In this article, we review six use cases for wearables that are relevant to the military and first responders. We examine the metrics measured and the wearables used. We conclude with recommendations for requirements and wearable selection given the constraints imposed by various use cases.
- 15 February 2024
- Published by RTI Press
Open AccessWearable Sensors for Service Members and First Responders: Considerations for Using Commercially Available Sensors in Continuous Monitoring
Wearable sensors (“wearables”) provide a mechanism to monitor the health of service members and first responders continuously and remotely. Several wearables are commercially available, with different configurations, sensors, algorithms, and forms of communication. Choosing the “best” wearable depends on the information you need to make decisions, how often you need this information, and the level of accuracy required. In this article, we review six use cases for wearables that are relevant to the military and first responders. We examine the metrics measured and the wearables used. We conclude with recommendations for requirements and wearable selection given the constraints imposed by various use cases.
- Open Access
- 27 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Continuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study (Preprint)
BACKGROUND Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. OBJECTIVE In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. METHODS A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. RESULTS The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. CONCLUSIONS We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- 27 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContinuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study (Preprint)
BACKGROUND Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. OBJECTIVE In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. METHODS A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. RESULTS The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. CONCLUSIONS We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- Open Access
- 16 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Effects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study (Preprint)
BACKGROUND Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors. OBJECTIVE This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings. METHODS Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor. RESULTS At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P<.001) were unstable at 10% data degradation. LF (rest: P<.001; activity: P<.001), HF (rest: P<.001, activity: P<.001), and LF/HF (rest: P<.001, activity: P<.001) were unstable at 10% data degradation during rest and activity. Median IBI values calculated from photoplethysmography sensors had a moderate agreement (intraclass correlation coefficient [ICC]=0.585) and consistency (ICC=0.589) and LF had moderate consistency (ICC=0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC=0.071-0.472). CONCLUSIONS This study describes a methodology for the extraction of HRV metrics from photoplethysmography sensor data that resulted in stable and valid metrics while using the least amount of available data. While smartwatches containing photoplethysmography sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.
- 16 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEffects of Missing Data on Heart Rate Variability Measured From A Smartwatch: Exploratory Observational Study (Preprint)
BACKGROUND Measuring heart rate variability (HRV) through wearable photoplethysmography sensors from smartwatches is gaining popularity for monitoring many health conditions. However, missing data caused by insufficient wear compliance or signal quality can degrade the performance of health metrics or algorithm calculations. Research is needed on how to best account for missing data and to assess the accuracy of metrics derived from photoplethysmography sensors. OBJECTIVE This study aimed to evaluate the influence of missing data on HRV metrics collected from smartwatches both at rest and during activity in real-world settings and to evaluate HRV agreement and consistency between wearable photoplethysmography and gold-standard wearable electrocardiogram (ECG) sensors in real-world settings. METHODS Healthy participants were outfitted with a smartwatch with a photoplethysmography sensor that collected high-resolution interbeat interval (IBI) data to wear continuously (day and night) for up to 6 months. New datasets were created with various amounts of missing data and then compared with the original (reference) datasets. 5-minute windows of each HRV metric (median IBI, SD of IBI values [STDRR], root-mean-square of the difference in successive IBI values [RMSDRR], low-frequency [LF] power, high-frequency [HF] power, and the ratio of LF to HF power [LF/HF]) were compared between the reference and the missing datasets (10%, 20%, 35%, and 60% missing data). HRV metrics calculated from the photoplethysmography sensor were compared with HRV metrics calculated from a chest-worn ECG sensor. RESULTS At rest, median IBI remained stable until at least 60% of data degradation (P=.24), STDRR remained stable until at least 35% of data degradation (P=.02), and RMSDRR remained stable until at least 35% data degradation (P=.001). During the activity, STDRR remained stable until 20% data degradation (P=.02) while median IBI (P=.01) and RMSDRR P<.001) were unstable at 10% data degradation. LF (rest: P<.001; activity: P<.001), HF (rest: P<.001, activity: P<.001), and LF/HF (rest: P<.001, activity: P<.001) were unstable at 10% data degradation during rest and activity. Median IBI values calculated from photoplethysmography sensors had a moderate agreement (intraclass correlation coefficient [ICC]=0.585) and consistency (ICC=0.589) and LF had moderate consistency (ICC=0.545) with ECG sensors. Other HRV metrics demonstrated poor agreement (ICC=0.071-0.472). CONCLUSIONS This study describes a methodology for the extraction of HRV metrics from photoplethysmography sensor data that resulted in stable and valid metrics while using the least amount of available data. While smartwatches containing photoplethysmography sensors are valuable for remote monitoring of patients, future work is needed to identify best practices for using these sensors to evaluate HRV in medical settings.
- Open Access
- 4 September 2023
- Published by MDPI AG in Applied System Innovation
- Vol. 6 (5) , 79
Modular Open-Core System for Collection and Near Real-Time Processing of High-Resolution Data from Wearable Sensors
Wearable devices, such as smartwatches integrating heart rate and activity sensors, have the potential to transform health monitoring by enabling continuous, near real-time data collection and analytics. In this paper, we present a novel modular architecture for collecting and end-to-end processing of high-resolution signals from wearable sensors. The system obtains minimally processed data directly from the smartwatch and further processes and analyzes the data stream without transmitting it to the device vendor cloud. The standalone operation is made possible by a software stack that provides data cleaning, extraction of physiological metrics, and standardization of the metrics to enable person-to-person and rest-to-activity comparisons. To illustrate the operation of the system, we present examples of datasets from volunteers wearing Garmin Fenix smartwatches for several weeks in free-living conditions. As collected, the datasets contain time series of each interbeat interval and the respiration rate, blood oxygen saturation, and step count every 1 min. From the high-resolution datasets, we extract heart rate variability metrics, which are a source of information about the heart’s response to external stressors. These biomarkers can be used for the early detection of a range of diseases and the assessment of physical and mental performance of the individual. The data collection and analytics system has the potential to broaden the use of smartwatches in continuous near to real-time monitoring of health and well-being.
- 4 September 2023
- Published by MDPI AG in Applied System Innovation
- Vol. 6 (5) , 79
Open AccessModular Open-Core System for Collection and Near Real-Time Processing of High-Resolution Data from Wearable Sensors
Wearable devices, such as smartwatches integrating heart rate and activity sensors, have the potential to transform health monitoring by enabling continuous, near real-time data collection and analytics. In this paper, we present a novel modular architecture for collecting and end-to-end processing of high-resolution signals from wearable sensors. The system obtains minimally processed data directly from the smartwatch and further processes and analyzes the data stream without transmitting it to the device vendor cloud. The standalone operation is made possible by a software stack that provides data cleaning, extraction of physiological metrics, and standardization of the metrics to enable person-to-person and rest-to-activity comparisons. To illustrate the operation of the system, we present examples of datasets from volunteers wearing Garmin Fenix smartwatches for several weeks in free-living conditions. As collected, the datasets contain time series of each interbeat interval and the respiration rate, blood oxygen saturation, and step count every 1 min. From the high-resolution datasets, we extract heart rate variability metrics, which are a source of information about the heart’s response to external stressors. These biomarkers can be used for the early detection of a range of diseases and the assessment of physical and mental performance of the individual. The data collection and analytics system has the potential to broaden the use of smartwatches in continuous near to real-time monitoring of health and well-being.
- 17 February 2017
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 51 (5) , 576-586
Long-term viable bioaerosol sampling using a temperature- and humidity-controlled filtration apparatus, a laboratory investigation using culturable E. coli.
Sampling for culturable (e.g., viable) aerosolized microbes (bioaerosols) is a useful means to provide information for public health monitoring and studies. However, it is challenging to maintain microbe culturability when sampling at high flow rates (>12 L/min) and extended periods of time (≥4 h). We developed a first-generation, viable bioaerosol collection system (VBCS) utilizing temperature (T) and relative humidity (RH)–conditioned filtration at a flow rate of 25 L/min. A two-stage system of tube-in-shell Nafion™ exchange units provides cooling to ≤10°C and RH conditioning to 80–95%. Aerosol particles are collected on a polyurethane nanofiber filter providing a physical collection efficiency of >95% for sizes 0.06–10 µm. The T and RH conditions at the collection filter are maintained, despite changes to ambient conditions. The initial testing of the VBCS was done under indoor, laboratory conditions with aerosolized, vegetative E. coli. A scenario of a 30-min challenge of bioaerosol followed by continued sampling of clean air for various times was used to judge culturability maintenance under extended-term sampling. An initial loss of culturability upon collection onto the filter was observed; 23 ± 13% relative to 4-mm all-glass impinger. However once collected, 98% of culturability was maintained for an additional 4.5 h of sampling. An exponential decay in culturability was observed from 8 h to 15 h of sampling. Also, 24-h cold storage of the filters collected was studied. The VBCS is based on the use of dry filter cassettes, needs minimal maintenance, and preserves culturability of vegetative bacteria for >4 h. © 2017 RTI International and Aerosol Dynamics Inc.
- 17 February 2017
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 51 (5) , 576-586
Long-term viable bioaerosol sampling using a temperature- and humidity-controlled filtration apparatus, a laboratory investigation using culturable E. coli.
Sampling for culturable (e.g., viable) aerosolized microbes (bioaerosols) is a useful means to provide information for public health monitoring and studies. However, it is challenging to maintain microbe culturability when sampling at high flow rates (>12 L/min) and extended periods of time (≥4 h). We developed a first-generation, viable bioaerosol collection system (VBCS) utilizing temperature (T) and relative humidity (RH)–conditioned filtration at a flow rate of 25 L/min. A two-stage system of tube-in-shell Nafion™ exchange units provides cooling to ≤10°C and RH conditioning to 80–95%. Aerosol particles are collected on a polyurethane nanofiber filter providing a physical collection efficiency of >95% for sizes 0.06–10 µm. The T and RH conditions at the collection filter are maintained, despite changes to ambient conditions. The initial testing of the VBCS was done under indoor, laboratory conditions with aerosolized, vegetative E. coli. A scenario of a 30-min challenge of bioaerosol followed by continued sampling of clean air for various times was used to judge culturability maintenance under extended-term sampling. An initial loss of culturability upon collection onto the filter was observed; 23 ± 13% relative to 4-mm all-glass impinger. However once collected, 98% of culturability was maintained for an additional 4.5 h of sampling. An exponential decay in culturability was observed from 8 h to 15 h of sampling. Also, 24-h cold storage of the filters collected was studied. The VBCS is based on the use of dry filter cassettes, needs minimal maintenance, and preserves culturability of vegetative bacteria for >4 h. © 2017 RTI International and Aerosol Dynamics Inc.
- Open Access
- 2 June 2016
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 50 (8) , 802-811
Generation and sampling of nanoscale infectious viral aerosols
Airborne viruses represent a potentially significant health threat. However, only recently have researchers begun to characterize the size and infectivity of viral bioaerosols in the nanoscale size range. There are limitations in the generation of test viral aerosols and the ability to sample with acceptable efficiency. Reported here is use of a laminar-flow water condensation method to efficiently sample nanoscale bioaerosols to sizes well below 100 nm. We used MS2 bacteriophage in water to provide an aerosol with particles sizes from 300 nm down to 45 nm for sampling by both an all-glass impinger (4 mm; AGI-4) and the water condensation bioaerosol sampler. We demonstrated the existence of infectious viral particles below 100 nm and a higher collection efficiency by the water condensation sampler compared to the AGI-4 at nanoscale sizes. For example, the water condensation bioaerosol sampler that collected particles at 45 nm in diameter had 20 times more infective virions per collected particle compared to the AGI-4. However, when we corrected the AGI-4 data for particle size–dependent collection efficiency, the results were similar. We also used quantitative reverse transcription polymerase chain reaction, along with culturing for infectivity to determine the percent infectivity of the aerosol by particle size. Finally, we used a simple calculation to determine that a large fraction of sub-100 nm particles did not contain infectious virus because of the low titer concentration of virus in the Collison fluid. © 2016 RTI International
- 2 June 2016
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 50 (8) , 802-811
Open AccessGeneration and sampling of nanoscale infectious viral aerosols
Airborne viruses represent a potentially significant health threat. However, only recently have researchers begun to characterize the size and infectivity of viral bioaerosols in the nanoscale size range. There are limitations in the generation of test viral aerosols and the ability to sample with acceptable efficiency. Reported here is use of a laminar-flow water condensation method to efficiently sample nanoscale bioaerosols to sizes well below 100 nm. We used MS2 bacteriophage in water to provide an aerosol with particles sizes from 300 nm down to 45 nm for sampling by both an all-glass impinger (4 mm; AGI-4) and the water condensation bioaerosol sampler. We demonstrated the existence of infectious viral particles below 100 nm and a higher collection efficiency by the water condensation sampler compared to the AGI-4 at nanoscale sizes. For example, the water condensation bioaerosol sampler that collected particles at 45 nm in diameter had 20 times more infective virions per collected particle compared to the AGI-4. However, when we corrected the AGI-4 data for particle size–dependent collection efficiency, the results were similar. We also used quantitative reverse transcription polymerase chain reaction, along with culturing for infectivity to determine the percent infectivity of the aerosol by particle size. Finally, we used a simple calculation to determine that a large fraction of sub-100 nm particles did not contain infectious virus because of the low titer concentration of virus in the Collison fluid. © 2016 RTI International
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1240
Optical Properties of Electrospun Nanofiber Substrates
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1240
Optical Properties of Electrospun Nanofiber Substrates
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1240
Photoluminescent Nanofibers for Solid-State Lighting Applications
Photoluminescent nanofibers (PLN) can be formed by combining electrospun polymeric nanofibers and luminescent particles such as quantum dots (QD). The physical properties of PLNs are dependent upon many different nanoscale parameters associated with the nanofiber, the luminescent particles, and their interactions. By understanding and manipulating these properties, the performance of the resulting optical structure can be tailored for desired end-use applications. For example, the quantum efficiency of quantum dots in the PLN structure depends upon multiple parameters including quantum dot chemistry, the method of forming the PLN nanocomposites, and preventing agglomeration of the quantum dot particles. This is especially important in solution-based electrospinning environments where some common solvents may have a detrimental effect on the performance of the PLN. With the proper control of these parameters, high quantum efficiencies can be readily obtained for PLNs. Achieving high quantum efficiencies is critical in applications such as solid-state lighting where PLNs can be an effective secondary conversion material for producing white light. Methods of optimizing the performance of PLNs through nanoscale manipulation of the nanofiber are discussed along with guidelines for tailoring the performance of nanofibers and quantum dots for application-specific requirements.
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1240
Photoluminescent Nanofibers for Solid-State Lighting Applications
Photoluminescent nanofibers (PLN) can be formed by combining electrospun polymeric nanofibers and luminescent particles such as quantum dots (QD). The physical properties of PLNs are dependent upon many different nanoscale parameters associated with the nanofiber, the luminescent particles, and their interactions. By understanding and manipulating these properties, the performance of the resulting optical structure can be tailored for desired end-use applications. For example, the quantum efficiency of quantum dots in the PLN structure depends upon multiple parameters including quantum dot chemistry, the method of forming the PLN nanocomposites, and preventing agglomeration of the quantum dot particles. This is especially important in solution-based electrospinning environments where some common solvents may have a detrimental effect on the performance of the PLN. With the proper control of these parameters, high quantum efficiencies can be readily obtained for PLNs. Achieving high quantum efficiencies is critical in applications such as solid-state lighting where PLNs can be an effective secondary conversion material for producing white light. Methods of optimizing the performance of PLNs through nanoscale manipulation of the nanofiber are discussed along with guidelines for tailoring the performance of nanofibers and quantum dots for application-specific requirements.