4-D Flow MRI-Based Computational Analysis of Blood Flow in Patient-Specific Aortic Dissection
Authors:
- Selene PirolaSPSelene Pirola
- Baolei GuoBGBaolei Guo
- Claudia MenichiniCMClaudia Menichini
- Simone SaittaSSSimone Saitta
- Weiguo FuWFWeiguo Fu
- Zhihui DongZDZhihui Dong
- Xiao Yun XuXXXiao Yun Xu
Open Access
- 13 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (12) , 3411-3419
Abstract
Computational hemodynamic studies of aortic dissections usually combine patient-specific geometries with idealized or generic boundary conditions. In this study, we present a comprehensive methodology for the simulation of hemodynamics in type B aortic dissection (TBAD), based on fully patient-specific boundary conditions. Pre-operative four-dimensional (4-D) flow magnetic resonance imaging (MRI) and Doppler-wire pressure measurements (pre- and post-operative) were acquired from a TBAD patient. These data were used to derive boundary conditions for computational modeling of flow before and after thoracic endovascular repair (TEVAR). Validations of the computational results were performed by comparing predicted flow patterns with pre-TEVAR 4-D flow MRI, as well as pressures with in vivo measurements. Comparison of instantaneous velocity streamlines showed a good qualitative agreement with 4-D flow MRI. Quantitative comparison of predicted pressures with pressure measurements revealed a maximum difference of 11 mmHg (-9.7%). Furthermore, our model correctly predicted the reduction of true lumen pressure from 74/115 mmHg pre-TEVAR to 64/107 mmHg post-TEVAR (diastolic/systolic pressures at entry tear level), compared to the corresponding measurements of 72/118 mmHg and 64/114 mmHg. This demonstrates that pre-TEVAR 4D flow MRI can be used to tune boundary conditions for post-TEVAR hemodynamic analyses.Keywords
Funding Information
- National Natural Science Foundation of China (81470573, 81371648, 81770474, 81770508)
- Shanghai Committee of Science and Technology, China (16410722900)
- The Royal Society U.K. (IE161052)
- European Commission within the Horizon 2020 Framework through the MSCA-ITN-ETN (642458)
This publication has 38 references indexed in Scilit:
- Four‐dimensional phase contrast MRI with accelerated dual velocity encodingJournal of Magnetic Resonance Imaging, 2012
- On the Use of In Vivo Measured Flow Rates as Boundary Conditions for Image-Based Hemodynamic Models of the Human Aorta: Implications for Indicators of Abnormal FlowAnnals of Biomedical Engineering, 2011
- Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical ReportEuropean Journal of Vascular and Endovascular Surgery, 2011
- Investigation of hemodynamics in the development of dissecting aneurysm within patient-specific dissecting aneurismal aortas using computational fluid dynamics (CFD) simulationsJournal of Biomechanics, 2011
- Analysis of Flow Patterns in a Patient-Specific Aortic Dissection ModelJournal of Biomechanical Engineering, 2010
- In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance ImagingAnnals of Biomedical Engineering, 2008
- Hemodynamic shear stress and the endothelium in cardiovascular pathophysiologyNature Clinical Practice Cardiovascular Medicine, 2008
- Helical flow as fluid dynamic signature for atherogenesis risk in aortocoronary bypass. A numeric studyJournal of Biomechanics, 2007
- Does shear stress modulate both plaque progression and regression in the thoracic aorta?JACC, 2005
- Relation between diameter and flow in major branches of the arch of the aortaJournal of Biomechanics, 1992