SPSelene Pirola

Selene Pirola

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Selene Pirola has a total of 118 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Trans-stenotic pressure drop estimation from PC-MRI and ultrasound imaging velocimetry using a modified Bernoulli equation

    by Ali Amiri, Johan T. Padding, Selene Pirola, Willian Hogendoorn

    Accurate non-invasive estimation of trans-stenotic pressure drops remains a challenge. In clinical practice, pressure drops are often estimated from velocity measurements using Bernoulli-based formulas, but these simplified relations do not explicitly account for how pressure losses change with the flow regime. Here, we introduce a modified Bernoulli (MB) formulation that incorporates regime-dependent pressure losses through a Reynolds-number-dependent loss coefficient. Steady in-vitro experiments were performed in an idealized stenosis model over physiologically relevant flow rates (0.65–3.9 L/min), combining direct pressure measurements with ultrasound imaging velocimetry (UIV) and phase-contrast magnetic resonance imaging (PC-MRI) to measure velocities. The MB model was calibrated from the measured pressure drops and then evaluated against the simplified Bernoulli (SB) and extended Bernoulli (EB) formulations. Over the tested flow regime, MB agreed best with the measurements (typically within about ±10% ). SB and EB showed larger biases, with errors of roughly 10–55% (SB) and -15 to 25%−(EB), and overestimated the pressure drop in the clinically relevant range. We additionally quantified the effect of PC-MRI in-plane pixel size on MRI-based pressure estimates. Coarse in-plane pixel size of 1.33 mm, corresponding to only approximately 3–4 pixels across the 3.3 mm throat radius of the 6.6 mm stenosis throat, led to systematic underestimation of flow rate and bulk velocity (about − 34 to − 44%) and, consequently, of the MB-predicted pressure drop (about − 52 to − 62%). In contrast, the peak throat velocity was substantially less sensitive to pixel size, resulting in smaller estimation errors (about − 13 to − 18.7%) when used as input for the MB. Overall, the results demonstrate that accounting for flow-regime-dependent loss mechanisms enhances pressure drop estimation, and that sufficient sampling of the stenotic throat is crucial for MRI-based flow rate and pressure drop estimation. In addition, peak-velocity-based MB pressure drop estimations are less sensitive to pixel size.

  • Haemodynamic impact of implant materials and anastomotic angle in femoro-popliteal artery grafts

    by Sabrina Schoenborn, Thomas Lloyd, Yogeesan Sivakumaran, Maria A. Woodruff, David F. Fletcher, Selene Pirola, Mark C. Allenby

    End-to-side anastomoses are commonly utilised in peripheral arterial bypass surgery and are plagued by high rates of re-stenosis which are contributed to by non-physiological blood flow impacting the arterial and graft structures. Computational simulations can examine how patient-specific surgical decisions in bypass graft placement and material selection affect blood flow and future risk of graft restenosis. Despite graft geometry and compliance being key predictors of restenosis, current simulations of femoro-popliteal artery grafts do not consider the interaction of flowing blood with compliant vessel, graft, and suture structures. Utilising fluid–structure interaction simulations, this study examines the impact of surgical technique, such as anastomosis angle, graft material, and suture material, on blood flow and fluid–structure forces in patient-specific asymptomatic arterial tree versus side-to-end peripheral grafts for symptomatic atherosclerotic disease. To render these complex simulations numerically feasible, our pipeline uses regional suture mechanics and a pre-stress pipeline previously validated in small-scale idealised models. Our simulations found that higher anastomosis angles generate larger regions of slow and recirculating blood, characterised by non-physiologically low shear stress and high oscillatory shear index. The use of compliant graft materials reduces regions of non-physiologically high shear stress only when used in combination with compliant suture materials. Altogether, our fluid–structure interaction simulation provides patient-specific platforms for vascular surgery decisions concerning graft geometry and material.

  • Open Access

    Morphometry of Intracranial Carotid Artery Calcifications in Patients with Recent Cerebral Ischemia

    by Bernhard P. Berghout, Federica Fontana, Fennika Huijben, Suze-Anne Korteland, M. Eline Kooi, Paul J. Nederkoorn, Pim A. de Jong, Frank J. Gijsen, Selene Pirola, M. Kamran Ikram, et al.

    Background: Intracranial artery calcification detected on CT imaging is a recognized risk factor for ischemic cerebrovascular diseases, but the underlying etiology of this association remains unclear. Differences in objective morphometric characteristics of these calcifications may partially explain this association, yet these measurements are largely absent in the literature. We investigated intracranial artery calcification morphometry in patients with recent anterior ischemic stroke or TIA, assessing potential differences between calcifications in both intracranial carotid arteries (ICAs) located ipsilateral and contralateral to the cerebral ischemia. Methods: Among 100 patients (mean age 69.6 (SD 8.8) years) presenting to academic neurology departments, 3D reconstructions of both ICAs were based on clinical CT-angiography images. On these reconstructions, a luminal centerline and cross-sections perpendicular to this centerline were created, facilitating the assessment of calcification morphometry, spatial orientation and stenosis severity. Differences in calcification characteristics between ICAs were assessed using two-sided Wilcoxon signed-rank and χ2 tests. Results: Among 200 arteries, a median of four (IQR 2–6) individual calcifications were counted, with a mean area of 1.8 (IQR 1.2–2.7) mm2, a mean arc width of 43.5 (IQR 32.3–53.2) degrees, and median longitudinal extent of 15.4 (IQR 5.9–27.0) mm. Calcifications were most often present in the anatomical C4 section (56.0%), with predominantly posterosuperior orientation (38.5%) and 42.0% had a local stenosis severity > 70%. None of these aspects significantly differed between ICAs, and this remained after restricting analyses to patients with undetermined etiology. Conclusions: We found no differences in morphometrical or spatial aspects of calcifications between ICAs ipsilateral and contralateral to the cerebral ischemia.


  • Open Access

    Simulating big mechanically-active culture systems (BigMACS) using paired biomechanics-histology FEA modelling to derive mechanobiology design relationships

    by Sabrina Schoenborn, Mingyang Yuan, Cody A Fell, Chuanhai Liu, David F Fletcher, Selene Priola, Hon Fai Chan, Mia Woodruff, Zhiyong Li, Yi-Chin Toh, et al.

    Big mechanically-active culture systems (BigMACS) are promising to stimulate, control, and pattern cell and tissue behaviours with less soluble factor requirements. However, it remains challenging to predict if and how distributed mechanical forces impact single-cell behaviours to pattern tissue. In this study, we introduce a tissue-scale finite element analysis framework able to correlate sub-cellular quantitative histology with centimetre-scale biomechanics. Our framework is relevant to diverse BigMACS, including media perfusion, tensile-stress, magnetic, and pneumatic tissue culture platforms. We apply our framework to understand how the design and operation of a multi-axial soft robotic bioreactor can spatially control mesenchymal stem cell (MSC) proliferation, orientation, differentiation to smooth muscle, and extracellular vascular matrix deposition. We find MSC proliferation and matrix deposition to positively correlate with mechanical stimulation but cannot be locally patterned by soft robot mechanical stimulation within a centimetre scale tissue. In contrast, local stress distribution was able to locally pattern MSC orientation and differentiation to smooth muscle phenotypes, where MSCs aligned perpendicular to principal stress direction and expressed increased α-SMA with increasing 3D Von Mises Stresses from 0 to 15 kPa. Altogether, our new biomechanical-histological simulation framework is a promising technique to derive the future mechanical design equations to control cell behaviours and engineer patterned tissue.


  • Open Access

    Haemodynamic impact of implant materials and anastomotic angle in peripheral vascular grafts

    by Sabrina Schoenborn, Thomas Lloyd, Yogeesan Sivakumaran, Maria A. Woodruff, David F. Fletcher, Selene Pirola, Mark C. Allenby

    End-to-side anastomoses are commonly utilised in peripheral arterial bypass surgery and are plagued by high rates of re-stenosis as a result of non-physiological blood flow impacting arterial and graft structures. Computational simulations can examine how patient-specific surgical decisions in bypass graft placement and material selection affect blood flow and future risk of graft restenosis. Despite graft geometry and compliance being key predictors of restenosis, current simulations do not consider the interaction of flowing blood with compliant vessel, graft, and suture structures. Utilising fluid-structure interaction simulations, this study examines the impact of surgical technique, such as anastomosis angle, graft material, and suture material, on blood flow and fluid-structure forces in patient-specific asymptomatic arterial tree versus side-to-end peripheral grafts for symptomatic atherosclerotic disease. To render these complex simulations numerically feasible, our pipeline uses regional suture mechanics and a pre-stress pipeline previously validated in small-scale idealised models. Our simulations found that higher anastomosis angles generate larger regions of slow and recirculating blood, characterised by non-physiologically low shear stress and high oscillatory shear index. The use of compliant graft materials reduces regions of non-physiologically high shear stress only when used in combination with compliant suture materials. Altogether, our fluid-structure interaction simulation provides patient-specific platforms for vascular surgery decisions concerning graft geometry and material. Highlights: Simulating bypass graft haemodynamics with realistic fluid-structure interactions. Bypass grafts generate large regions of slow blood flow and blood recirculation. Greater graft anastomosis angles correlate with larger blood recirculation regions. Nonphysiologically stiff graft and suture materials increase vessel shear stress.

  • Open Access

    Simulating big mechanically-active culture systems (BigMACS) using paired biomechanics-histology FEA modelling to derive mechanobiology design relationships

    by Sabrina Schoenborn, Mingyang Yuan, Cody A. Fell, Chuanhai Liu, David F. Fletcher, Selene Priola, Hon Fai Chan, Mia Woodruff, Zhiyong Li, Yi-Chin Toh, et al.

    Big mechanically-active culture systems (BigMACS) are promising to stimulate, control, and pattern cell and tissue behaviours with less soluble factor requirements, however, it remains challenging to predict if and how distributed mechanical forces impact single-cell behaviours to pattern tissue. In this study, we introduce a centimetre, tissue-scale, finite element analysis (FEA) framework able to correlate sub-cellular quantitative histology with centimetre-scale biomechanics. Our framework is relevant to diverse bigMACS; media perfusion, tensile-stress, magnetic, and pneumatic tissue culture platforms. We apply our framework to understand how the design and operation of a multi-axial soft robotic bioreactor can spatially control mesenchymal stem cell (MSC) proliferation, orientation, differentiation to smooth muscle, and extracellular vascular matrix deposition. We find MSC proliferation and matrix deposition correlate positively with mechanical stimulation but cannot be locally patterned by soft robot mechanical stimulation within a centimetre scale tissue. In contrast, local stress distribution was able to locally pattern MSC orientation and differentiation to smooth muscle phenotypes, where MSCs aligned perpendicular to principal stress direction and expressed increased α-SMA with increasing 3D Von Mises Stresses from 0 to 15 kPa. Altogether, our new biomechanical-histological simulation framework is a promising technique to derive the future mechanical design equations to control cell behaviours and engineer patterned tissue generation.

  • Interactions Between Medical Devices and Blood Flow

    by Victoria Schuman, Prem Midha, Brandon Moore, Harkamaljot Kandail, Xuanhe Du, Selene Pirola

  • Open Access

    Fluid–structure interaction analysis of a healthy aortic valve and its surrounding haemodynamics

    by Zhongjie Yin, Chlöe Armour, Harkamaljot Kandail, Declan P. O'REgan, Toufan Bahrami, Saeed Mirsadraee, Selene Pirola, Xiao Yun Xu

    The opening and closing dynamics of the aortic valve (AV) has a strong influence on haemodynamics in the aortic root, and both play a pivotal role in maintaining normal physiological functions of the valve. The aim of this study was to establish a subject‐specific fluid–structure interaction (FSI) workflow capable of simulating the motion of a tricuspid healthy valve and the surrounding haemodynamics under physiologically realistic conditions. A subject‐specific aortic root was reconstructed from magnetic resonance (MR) images acquired from a healthy volunteer, whilst the valve leaflets were built using a parametric model fitted to the subject‐specific aortic root geometry. The material behaviour of the leaflets was described using the isotropic hyperelastic Ogden model, and subject‐specific boundary conditions were derived from 4D‐flow MR imaging (4D‐MRI). Strongly coupled FSI simulations were performed using a finite volume‐based boundary conforming method implemented in FlowVision. Our FSI model was able to simulate the opening and closing of the AV throughout the entire cardiac cycle. Comparisons of simulation results with 4D‐MRI showed a good agreement in key haemodynamic parameters, with stroke volume differing by 7.5% and the maximum jet velocity differing by less than 1%. Detailed analysis of wall shear stress (WSS) on the leaflets revealed much higher WSS on the ventricular side than the aortic side and different spatial patterns amongst the three leaflets.


  • Open Access

    Aortic valve neocuspidization and bioprosthetic valves: Evaluating turbulence haemodynamics

    by Emily Louise Manchester, Selene Pirola, Sergio Pirola, Giorgio Mastroiacovo, Gianluca Polvani, Gianluca Pontone, Xiao Yun Xu


  • Open Access

    Fluid-Structure Interactions of Peripheral Arteries Using a Coupled in silico and in vitro Approach

    by S. Schoenborn, T. Lorenz, K. Kuo, D.F. Fletcher, M. A. Woodruff, S. Pirola, M. C. Allenby

    Vascular compliance is considered both a cause and a consequence of cardiovascular disease and a significant factor in the mid- and long-term patency of vascular grafts. However, the biomechanical effects of localised changes in compliance, such as during plaque development or after bypass grafting and stenting, cannot be satisfactorily studied with the available medical imaging technologies or surgical simulation materials. To address this unmet need, we developed a coupled silico-vitro platform which allows for the validation of numerical fluid-structure interaction (FSI) results as a numerical model and physical prototype. This numerical one-way and two-way FSI study is based on a three-dimensional computer model of an idealised femoral artery which is validated against patient measurements derived from the literature. The numerical results are then compared with experimental values collected from compliant arterial phantoms. Phantoms within a compliance range of 1.4 - 68.0%/100mmHg were fabricated via additive manufacturing and silicone casting, then mechanically characterised via ring tensile testing and optical analysis under direct pressurisation with differences in measured compliance ranging between 10 - 20% for the two methods. One-way FSI coupling underestimated arterial wall compliance by up to 14.71% compared to two-way FSI modelling. Overall, Smooth-On Solaris matched the compliance range of the numerical and in vivo patient models most closely out of the tested silicone materials. Our approach is promising for vascular applications where mechanical compliance is especially important, such as the study of diseases which commonly affect arterial wall stiffness, such as atherosclerosis, and the model-based design, surgical training, and optimisation of vascular prostheses.