Abstract
Purpose: Sodium (23Na) multi‐quantum coherences (MQC) MRI was accelerated using three‐dimensional (3D) and a dedicated five‐dimensional (5D) compressed sensing (CS) framework for simultaneous Cartesian single (SQ) and triple quantum (TQ) sodium imaging of in vivo human brain at 3.0 and 7.0 T.Theory and Methods: 3D 23Na MQC MRI requires multi‐echo paired with phase‐cycling and exhibits thus a multidimensional space. A joint reconstruction framework to exploit the sparsity in all imaging dimensions by extending the conventional 3D CS framework to 5D was developed. 3D MQC images of simulated brain, phantom and healthy brain volunteers obtained from 3.0 T and 7.0 T were retrospectively and prospectively undersampled. Performance of the CS models were analyzed by means of structural similarity index (SSIM), root mean squared error (RMSE), signal‐to‐noise ratio (SNR) and signal quantification of tissue sodium concentration and TQ/SQ ratio.Results: It was shown that an acceleration of three‐fold, leading to less than min of scan time with a resolution of at 3.0 T, are possible. 5D CS improved SSIM by 3%, 5%, 1% and reduced RMSE by 50%, 30%, 8% for in vivo SQ, TQ, and TQ/SQ ratio maps, respectively. Furthermore, for the first time prospective undersampling enabled unprecedented high resolution from to MQC images of in vivo human brain at 7.0 T without extending acquisition time.Conclusion: 5D CS proved to allow up to three‐fold acceleration retrospectively on 3.0 T data. 2‐fold acceleration was demonstrated prospectively at 7.0 T to reach higher spatial resolution of 23Na MQC MRI.Keywords
This publication has 56 references indexed in Scilit:
- Biomedical applications of sodium MRI in vivoJournal of Magnetic Resonance Imaging, 2013
- Simultaneous single‐quantum and triple‐quantum‐filtered MRI of 23Na (SISTINA)Magnetic Resonance in Medicine, 2012
- Compressed sensing sodium MRI of cartilage at 7T: Preliminary studyJournal of Magnetic Resonance, 2012
- B0 inhomogeneity‐insensitive triple‐quantum‐filtered sodium imaging using a 12‐step phase‐cycling schemeNMR in Biomedicine, 2010
- MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high fieldNeuroImage, 2010
- 23Na TQF NMR imaging for the study of spinal disc tissueJournal of Magnetic Resonance, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Serial triple quantum sodium MRI during non‐human primate focal brain ischemiaMagnetic Resonance in Medicine, 2006
- Design and construction of a realistic digital brain phantomIEEE Transactions on Medical Imaging, 1998
- Selecting the optimal focus measure for autofocusing and depth-from-focusIEEE Transactions on Pattern Analysis and Machine Intelligence, 1998