Christian Licht
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christian Licht has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Lothar R. Schad
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
2 shared publicationsMaxime Guye
Aix‐Marseille Univ CNRS, CRMBM Marseille France
2 shared publications- Simon Reichert
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
2 shared publications - Stanislas Rapacchi
Department of Radiology Lausanne University Hospital and University of Lausanne, CHUV UNIL Epalinges Switzerland
2 shared publications - Ahmed Ould Khaoua
Departamento de Mathematicas, Universidad de los Andes, Bogota, Colombia
1 shared publication - Alain Léger
Laboratoire de Mécanique et d’Acoustique, CNRS
1 shared publication
Latest Publications
- Open Access
- 10 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1440-1455
Low‐rank reconstruction for simultaneous double half‐echo 23Na and undersampled 23Na multi‐quantum coherences MRI
Purpose: To develop a new sequence to simultaneously acquire Cartesian sodium (23Na) MRI and accelerated Cartesian single (SQ) and triple quantum (TQ) sodium MRI of in vivo human brain at 7 T by leveraging two dedicated low‐rank reconstruction frameworks.Theory and Methods: The Double Half‐Echo technique enables short echo time Cartesian 23Na MRI and acquires two k‐space halves, reconstructed by a low‐rank coupling constraint. Additionally, three‐dimensional (3D) 23Na Multi‐Quantum Coherences (MQC) MRI requires multi‐echo sampling paired with phase‐cycling, exhibiting a redundant multidimensional space. Simultaneous Autocalibrating and k‐Space Estimation (SAKE) were used to reconstruct highly undersampled 23Na MQC MRI. Reconstruction performance was assessed against five‐dimensional (5D) CS, evaluating structural similarity index (SSIM), root mean squared error (RMSE), signal‐to‐noise ratio (SNR), and quantification of tissue sodium concentration and TQ/SQ ratio in silico, in vitro, and in vivo.Results: The proposed sequence enabled the simultaneous acquisition of fully sampled 23Na MRI while leveraging prospective undersampling for 23Na MQC MRI. SAKE improved TQ image reconstruction regarding SSIM by 6% and reduced RMSE by 35% compared to 5D CS in vivo. Thanks to prospective undersampling, the spatial resolution of 23Na MQC MRI was enhanced from mm3 to mm3 while reducing acquisition time from min to min.Conclusion: The proposed sequence, coupled with low‐rank reconstructions, provides an efficient framework for comprehensive whole‐brain sodium MRI, combining TSC, T2*, and TQ/SQ ratio estimations. Additionally, low‐rank matrix completion enables the reconstruction of highly undersampled 23Na MQC MRI, allowing for accelerated acquisition or enhanced spatial resolution.
- 10 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1440-1455
Open AccessLow‐rank reconstruction for simultaneous double half‐echo 23Na and undersampled 23Na multi‐quantum coherences MRI
Purpose: To develop a new sequence to simultaneously acquire Cartesian sodium (23Na) MRI and accelerated Cartesian single (SQ) and triple quantum (TQ) sodium MRI of in vivo human brain at 7 T by leveraging two dedicated low‐rank reconstruction frameworks.Theory and Methods: The Double Half‐Echo technique enables short echo time Cartesian 23Na MRI and acquires two k‐space halves, reconstructed by a low‐rank coupling constraint. Additionally, three‐dimensional (3D) 23Na Multi‐Quantum Coherences (MQC) MRI requires multi‐echo sampling paired with phase‐cycling, exhibiting a redundant multidimensional space. Simultaneous Autocalibrating and k‐Space Estimation (SAKE) were used to reconstruct highly undersampled 23Na MQC MRI. Reconstruction performance was assessed against five‐dimensional (5D) CS, evaluating structural similarity index (SSIM), root mean squared error (RMSE), signal‐to‐noise ratio (SNR), and quantification of tissue sodium concentration and TQ/SQ ratio in silico, in vitro, and in vivo.Results: The proposed sequence enabled the simultaneous acquisition of fully sampled 23Na MRI while leveraging prospective undersampling for 23Na MQC MRI. SAKE improved TQ image reconstruction regarding SSIM by 6% and reduced RMSE by 35% compared to 5D CS in vivo. Thanks to prospective undersampling, the spatial resolution of 23Na MQC MRI was enhanced from mm3 to mm3 while reducing acquisition time from min to min.Conclusion: The proposed sequence, coupled with low‐rank reconstructions, provides an efficient framework for comprehensive whole‐brain sodium MRI, combining TSC, T2*, and TQ/SQ ratio estimations. Additionally, low‐rank matrix completion enables the reconstruction of highly undersampled 23Na MQC MRI, allowing for accelerated acquisition or enhanced spatial resolution.
- Open Access
- 26 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 926-941
Multidimensional compressed sensing to advance 23Na multi‐quantum coherences MRI
Purpose: Sodium (23Na) multi‐quantum coherences (MQC) MRI was accelerated using three‐dimensional (3D) and a dedicated five‐dimensional (5D) compressed sensing (CS) framework for simultaneous Cartesian single (SQ) and triple quantum (TQ) sodium imaging of in vivo human brain at 3.0 and 7.0 T.Theory and Methods: 3D 23Na MQC MRI requires multi‐echo paired with phase‐cycling and exhibits thus a multidimensional space. A joint reconstruction framework to exploit the sparsity in all imaging dimensions by extending the conventional 3D CS framework to 5D was developed. 3D MQC images of simulated brain, phantom and healthy brain volunteers obtained from 3.0 T and 7.0 T were retrospectively and prospectively undersampled. Performance of the CS models were analyzed by means of structural similarity index (SSIM), root mean squared error (RMSE), signal‐to‐noise ratio (SNR) and signal quantification of tissue sodium concentration and TQ/SQ ratio.Results: It was shown that an acceleration of three‐fold, leading to less than min of scan time with a resolution of at 3.0 T, are possible. 5D CS improved SSIM by 3%, 5%, 1% and reduced RMSE by 50%, 30%, 8% for in vivo SQ, TQ, and TQ/SQ ratio maps, respectively. Furthermore, for the first time prospective undersampling enabled unprecedented high resolution from to MQC images of in vivo human brain at 7.0 T without extending acquisition time.Conclusion: 5D CS proved to allow up to three‐fold acceleration retrospectively on 3.0 T data. 2‐fold acceleration was demonstrated prospectively at 7.0 T to reach higher spatial resolution of 23Na MQC MRI.
- 26 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 926-941
Open AccessMultidimensional compressed sensing to advance 23Na multi‐quantum coherences MRI
Purpose: Sodium (23Na) multi‐quantum coherences (MQC) MRI was accelerated using three‐dimensional (3D) and a dedicated five‐dimensional (5D) compressed sensing (CS) framework for simultaneous Cartesian single (SQ) and triple quantum (TQ) sodium imaging of in vivo human brain at 3.0 and 7.0 T.Theory and Methods: 3D 23Na MQC MRI requires multi‐echo paired with phase‐cycling and exhibits thus a multidimensional space. A joint reconstruction framework to exploit the sparsity in all imaging dimensions by extending the conventional 3D CS framework to 5D was developed. 3D MQC images of simulated brain, phantom and healthy brain volunteers obtained from 3.0 T and 7.0 T were retrospectively and prospectively undersampled. Performance of the CS models were analyzed by means of structural similarity index (SSIM), root mean squared error (RMSE), signal‐to‐noise ratio (SNR) and signal quantification of tissue sodium concentration and TQ/SQ ratio.Results: It was shown that an acceleration of three‐fold, leading to less than min of scan time with a resolution of at 3.0 T, are possible. 5D CS improved SSIM by 3%, 5%, 1% and reduced RMSE by 50%, 30%, 8% for in vivo SQ, TQ, and TQ/SQ ratio maps, respectively. Furthermore, for the first time prospective undersampling enabled unprecedented high resolution from to MQC images of in vivo human brain at 7.0 T without extending acquisition time.Conclusion: 5D CS proved to allow up to three‐fold acceleration retrospectively on 3.0 T data. 2‐fold acceleration was demonstrated prospectively at 7.0 T to reach higher spatial resolution of 23Na MQC MRI.
- Open Access
- 1 August 2021
- Published by Elsevier in NeuroImage
- Vol. 237, 118138
Decoding the microstructural properties of white matter using realistic models
- 1 August 2021
- Published by Elsevier in NeuroImage
- Vol. 237, 118138
Open AccessDecoding the microstructural properties of white matter using realistic models
- 1 June 2013
- Published by Elsevier in Journal de Mathématiques Pures et Appliquées
- Vol. 99 (6) , 685-703
Dynamics of elastic bodies connected by a thin soft viscoelastic layer
- 1 June 2013
- Published by Elsevier in Journal de Mathématiques Pures et Appliquées
- Vol. 99 (6) , 685-703
Dynamics of elastic bodies connected by a thin soft viscoelastic layer
- 1 April 2009
- Published by Springer Nature in Journal of Elasticity
- Vol. 96 (1) , 57-79
Nonlinear Boundary Conditions in Kirchhoff-Love Plate Theory
- 1 April 2009
- Published by Springer Nature in Journal of Elasticity
- Vol. 96 (1) , 57-79
Nonlinear Boundary Conditions in Kirchhoff-Love Plate Theory