The feasibility of a dose painting procedure to treat prostate cancer based on mpMR images and hierarchical clustering
Open Access
- 20 September 2021
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-16
Abstract
Background: We aimed to assess the feasibility of a dose painting (DP) procedure, known as simultaneous integrated boost intensity modulated radiation Therapy (SIB-IMRT), for treating prostate cancer with dominant intraprostatic lesions (DILs) based on multi-parametric magnetic resonance (mpMR) images and hierarchical clustering with a machine learning technique.Methods: The mpMR images of 120 patients were used to create hierarchical clustering and draw a dendrogram. Three clusters were selected for performing agglomerative clustering. Then, the DIL acquired from the mpMR images of 20 patients were categorized into three groups to have them treated with a DP procedure being composed of three planning target volumes (PTVs) determined as PTV1, PTV2, and PTV3 in treatment plans. The DP procedure was carried out on the patients wherein a total dose of 80, 85 and 91 Gy were delivered to the PTV1, PTV2, and PTV3, respectively. Dosimetric and radiobiologic parameters [Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP)] of the DP procedure were compared with those of the conventional IMRT and Three-Dimensional Conformal Radiation Therapy (3DCRT) procedures carried out on another group of 20 patients. A post-treatment follow-up was also made four months after the radiotherapy procedures.Results: All the dosimetric variables and the NTCPs of the organs at risks (OARs) revealed no significant difference between the DP and IMRT procedures. Regarding the TCP of three investigated PTVs, significant differences were observed between the DP versus IMRT and also DP versus 3DCRT procedures. At post-treatment follow-up, the DIL volumes and apparent diffusion coefficient (ADC) values in the DP group differed significantly (p-value < 0.001) from those of the IMRT. However, the whole prostate ADC and prostate-specific antigen (PSA) indicated no significant difference (p-value > 0.05) between the DP versus IMRT.Conclusions: The results of this comprehensive clinical trial illustrated the feasibility of our DP procedure for treating prostate cancer based on mpMR images validated with acquired patients’ dosimetric and radiobiologic assessment and their follow-ups. This study confirms significant potential of the proposed DP procedure as a promising treatment planning to achieve effective dose escalation and treatment for prostate cancer.Trial registration: IRCT20181006041257N1; Iranian Registry of Clinical Trials, Registered: 23 October 2019,https://en.irct.ir/trial/34305.Keywords
All Related Versions
Funding Information
- Tarbiat Modares University (Med-77234)
This publication has 41 references indexed in Scilit:
- Comparison of 3D CRT and IMRT Tratment PlansActa Informatica Medica, 2013
- Radiobiologically guided optimisation of the prescription dose and fractionation scheme in radiotherapy using BioSuiteBritish Journal of Radiology, 2012
- Intensity-modulated Radiotherapy in the Treatment of Prostate CancerClinical Oncology, 2012
- Decision support system for localizing prostate cancer based on multiparametric magnetic resonance imagingMedical Physics, 2012
- ESUR prostate MR guidelines 2012European Radiology, 2012
- Algorithms for hierarchical clustering: an overviewWIREs Data Mining and Knowledge Discovery, 2011
- Single blind randomized Phase III trial to investigate the benefit of a focal lesion ablative microboost in prostate cancer (FLAME-trial): study protocol for a randomized controlled trialTrials, 2011
- Parameters Favorable to Intraprostatic Radiation Dose Escalation in Men With Localized Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Choline PET based dose-painting in prostate cancer - Modelling of dose effectsRadiation Oncology, 2010
- Tumour and Normal Tissue Responses to Fractionated Non-uniform Dose DeliveryInternational Journal of Radiation Biology, 1992