Location attempt of a degraded portion in a long polymer-insulated cable
Authors:
- 5 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 25 (6) , 2461-2466
Abstract
The ability of frequency domain reflectometry (FDR) for locating a portion in a cable longer than 1.0 km, where either degradation or abnormality occurred in its insulation, was evaluated by conducting two experiments. First, a 72-m coaxial cable insulated with low-density polyethylene (LDPE) was locally degraded concurrently by heat at 100 °C with gamma irradiation to 312 kGy. Then, this cable was connected to two 1000-m coaxial LDPE cables at either end. Furthermore, a 2-m coaxial lead LDPE cable was connected to a network analyzer, forming a cable of a total length of about 2074 m. The FDR method successfully located the degraded portion and also the connecting points in this long cable. It has also become clear that the FDR method can locate a 30-cm part in a 1000-m coaxial LDPE cable at a position about 900 m from its end when it was heated temporarily using a ribbon heater.Keywords
This publication has 23 references indexed in Scilit:
- Time–Frequency-Based Insulation Diagnostic Technique of High-Temperature Superconducting Cable SystemsIEEE Transactions on Applied Superconductivity, 2016
- Local degradation diagnosis for cable insulation based on broadband impedance spectroscopyIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Wire Fault Diagnosis in the Frequency Domain by Impedance SpectroscopyIEEE Transactions on Instrumentation and Measurement, 2015
- Estimation of thermal expansion coefficients of polymeric insulating films from temperature dependence of dielectric permittivityJapanese Journal of Applied Physics, 2014
- Detection and location of single cable fault by impedance spectroscopy2014
- Highly sensitive location method of an abnormal temperature point in a cable by frequency domain reflectometry2013
- On-line diagnosis using Orthogonal Multi-Tone Time Domain Reflectometry in a lossy cable2013
- Cable condition monitoring for nuclear power plants2012
- Power line network topology inference using Frequency Domain Reflectometry2012
- Application of joint time–frequency domain reflectometry for electric power cable diagnosticsIET Signal Processing, 2010