Does bone compaction around the helical blade of a proximal femoral nail anti-rotation (PFNA) decrease the risk of cut-out?
Authors:
Open Access
- 1 May 2013
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 2 (5) , 79-83
Abstract
Objectives: Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA). Methods: We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients. Results: We show that for a bone density corresponding to 100% of the bone density of the cadaveric femur, there does not seem to be any advantage in using a PFNA with respect to the risk of blade cut-out. On the other hand, in a more osteoporotic femoral head characterised by a density corresponding to 75% of the initial bone density, local bone compaction around the helical blade provides additional bone purchase, thereby decreasing the risk of cut-out, as quantified by the volume of bone susceptible to yielding. Conclusions: Our findings indicate benefits of using a PFNA over an intramedullary nail with a conventional lag screw and suggest that any clinical trial reporting surgical outcomes regarding the use of helical blades should include a measure of the femoral head bone density as a covariable.Keywords
This publication has 22 references indexed in Scilit:
- Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fracturesInternational Orthopaedics, 2011
- In vivo discrimination of hip fracture with quantitative computed tomography: Results from the prospective European Femur Fracture Study (EFFECT)Journal of Bone and Mineral Research, 2010
- Hip screw migration testing: First results for hip screws and helical blades utilizing a new oscillating test methodJournal of Orthopaedic Research, 2010
- Femoral head density on CT scans of patients following hip fracture fixation by expandable proximal peg or dynamic screwInjury, 2010
- Heterogeneity of yield strain in low-density versus high-density human trabecular boneJournal of Biomechanics, 2009
- The AO/ASIF proximal femoral nail antirotation (PFNA): A new design for the treatment of unstable proximal femoral fracturesInjury, 2009
- The new proximal femoral nail antirotation (PFNA®) in daily practice: Results of a multicentre clinical studyInjury, 2008
- Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitroJournal of Biomechanics, 2008
- Subject-specific finite element models can accurately predict strain levels in long bonesJournal of Biomechanics, 2007
- The Use of Endosteal Substitution in the Treatment of Recalcitrant Nonunions of the Femur: Report of Seven CasesJournal of Orthopaedic Trauma, 1996