Reliability of Refraction, Keratometry, and Intraocular Pressure Measurements with an Automated All‐in‐one Device
- 1 October 2021
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (10) , 1169-1176
Abstract
SIGNIFICANCE: This study explores the reliability of TonoRef II (Nidek, Tokyo, Japan), which represents a simple tool to obtain rapid refractometry and tonometry measurements. The present device demonstrates very high repeatability of refraction and intraocular pressure (IOP) readings as compared with subjective measurements and a higher concordance of IOP readings to Goldmann application tonometry (GAT). PURPOSE: This study aimed to evaluate the repeatability of measurements acquired with the Autorefractometer/Keratometer/Tonometer TonoRef II and assess their agreement to subjective measurements and readings of other established devices. METHODS: In a cross‐sectional study, 54 eyes of 54 healthy subjects were enrolled. Each subject underwent five measurements with the TonoRef II, three measurements with the Canon RK‐F1 Autorefractor Keratometer (Canon Europe NV, Amstelveen, the Netherlands), three IOP measurements with the Canon TX‐F Noncontact Tonometer (Canon Inc., Tokyo, Japan), three measurements with GAT, and a thorough subjective refraction. Repeatability coefficient ( r ), intraclass correlation coefficient (ICC), and Bland‐Altman plots were used to evaluate repeatability of readings and agreement to the subjective values. RESULTS: TonoRef II showed high repeatability (ICC >0.9) in all parameters tested (sphere, r = 0.157; cylinder, r = 0.196; IOP, r = 2.653). A strong correlation was found between TonoRef and Canon instruments ( P <. 001 in all parameters). Mean differences and limits of agreement (mean ± 1.96 standard deviation) were −0.01 ± 0.69 D, −0.11 ± 0.7 D, and 2.1 ± 3.4 mmHg for sphere, cylinder, and IOP, respectively. Both autorefractors achieved a very good to excellent agreement to the values obtained with the subjective refraction for most of the parameters tested, without any significant difference to each other ( P >. 05). Intraocular pressure measurements of TonoRef II showed higher agreement to the GAT values compared with those obtained with the Canon tonometer (ICC, 0.9114 and 0.7002, respectively; P <. 001). CONCLUSIONS: Intraocular pressure and refraction readings acquired with TonoRef II demonstrate very high repeatability and agreement to the subjective measurements. Regarding IOP evaluation, TonoRef II shows higher concordance to GAT compared with another established noncontact tonometer.Keywords
This publication has 33 references indexed in Scilit:
- Visual outcomes and patient satisfaction in 9366 eyes using a refractive segmented multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2013
- Prevalence of anisometropia and its association with refractive error and amblyopia in preschool childrenBritish Journal of Ophthalmology, 2013
- Systematic Review of the Agreement of Tonometers with Goldmann Applanation TonometryOphthalmology, 2012
- Clinically relevant biometryCurrent Opinion in Ophthalmology, 2012
- Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmologyOphthalmic and Physiological Optics, 2011
- Comparison of Goldmann Applanation Tonometer, Noncontact Tonometer, and TonoPen XL for Intraocular Pressure Measurement in Different Types of Glaucomatous, Ocular Hypertensive, and Normal EyesCurrent Eye Research, 2011
- A novel definition of the multivariate coefficient of variationBiometrical Journal, 2010
- Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact TonometryAmerican Journal of Ophthalmology, 2007
- A comparison of four methods of tonometry: method agreement and interobserver variabilityBritish Journal of Ophthalmology, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005