  • Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters

    by Vasileia Chatzistergiou, Argyrios Tzamalis, Asterios Diafas, Eirini Oustoglou, Asimina Mataftsi, Ioannis Tsinopoulos, Nikolaos Ziakas

    Purpose To assess the repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and identify correlations between epithelial thickness and ocular surface parameters. Methods Adults who happened to have prolonged computer use were recruited, excluding those with conditions interfering with corneal measurements or tear production. All subjects filled in the ocular surface disease index (OSDI) questionnaire. Three consecutive measurements of central and peripheral corneal and epithelial thickness were performed with SD-OCT (RTVue XR). Schirmer test I and tear film break-up time (TBUT) were performed. Repeatability was evaluated with intraclass correlation coefficient (ICC), coefficient of variation and repeatability limit. Spearman correlation was used for non-parametric variables. Results 113 eyes of 63 subjects were included in the study. ICC was ≥ 0.989 for all corneal and ≥ 0.944 for all epithelial pachymetry segments. The best repeatability was found centrally and the worst superiorly both for corneal and epithelial measurements. Central epithelial thickness was weakly correlated with Schirmer test I (rho = 0.21), TBUT (rho = 0.02), OSDI symptoms and OSDI score (rho <|0.32|). OSDI symptoms and OSDI score were weakly correlated with Schirmer test I (rho <|0.3|) and TBUT (rho <|0.34|). Conclusion RTVue XR measurements of corneal and epithelial thickness are highly repeatable in all segments. The lack of correlation between epithelial thickness and ocular surface parameters could suggest the assessment of epithelial integrity with reliable methods such as SD-OCT.


  • Open Access

    Comparison of adverse events between intravitreal anti-VEGF and laser photocoagulation for treatment-requiring retinopathy of prematurity: a systematic review

    by Georgios N. Tsiropoulos, Aikaterini K. Seliniotaki, Anna-Bettina Haidich, Nikolaos Ziakas, Asimina Mataftsi

    Purpose: To synthesize existing evidence on adverse events, complications, and unfavorable outcomes of current treatment modalities for treatment-requiring retinopathy of prematurity (TR-ROP). Methods: PubMed, Cochrane Central Register of Controlled Trials, Scopus, EMBASE, Trip Database, and the gray literature available were searched. Randomized Clinical Trials and observational studies comparing the adverse events of intravitreal anti-VEGF injections (bevacizumab, ranibizumab, aflibercept, pegaptanib, conbercept) and laser photocoagulation (LPC) as treatment modalities for infants with TR-ROP were included. The main outcomes compared between the two treatment modalities were: 1. Refractive Errors and Biometry Parameters, 2. Adverse events, complications, and unfavorable outcomes, 3. Disease Recurrence/Disease Regression/Need for retreatment, 4. Neurodevelopmental Outcomes. Results: Higher quality studies concluded that LPC leads to greater rates of myopia than intravitreal anti-VEGF treatment while the rate of adverse events and of unfavorable neurodevelopmental outcomes is similar. However, there was controversy among the included studies concerning the rate of ROP recurrence between intravitreal anti-VEGF injections and LPC. Conclusion: There is need for future primary studies assessing the adverse events of intravitreal anti-VEGF injections compared with LPC as treatment modalities for infants with TR-ROP.


  • Late-onset interface fluid syndrome: A case report and literature review

    by Spyridon Koronis, Asterios Diafas, Argyrios Tzamalis, Maria Samouilidou, Asimina Mataftsi, Nikolaos Ziakas

    To present a case of late-onset interface fluid syndrome (IFS) and a literature review on this rare clinical entity.IFS is an uncommon complication of laser in situ keratomileusis (LASIK). Although...


  • When should cataract surgeons seek assistance from experienced colleagues?

    by Eirini Oustoglou, Argyrios Tzamalis, Lamprini Banou, Chrysanthos D. Christou, Ioannis Tsinopoulos, Maria Samouilidou, Asimina Mataftsi, Nikolaos Ziakas

    Purpose To assess which cases should be assorted exclusively to high-volume surgeons and identify when should a cataract surgeon seek assistance from a senior colleague. Methods The medical records of 2853 patients with age-related cataract were reviewed. Preoperative risk factors were documented for each case, and they were divided into surgeons who had more (> 400 surgeries/year) or less experience (< 400 surgeries/year). Ophthalmology residents were excluded from this review. The cases that involved posterior capsule rupture, dropped nucleus, zonular dehiscence and anterior capsular tear with or without vitreous loss were defined as “complicated”. Results From the 3247 cataract extraction surgeries that were reviewed, we were unable to identify any statistically significant difference in the complication rates between the two surgeon groups. In the stepwise regression analysis, both groups supported advanced age (> 85) and mature cataracts with up to fourfold odds ratios (OR). Low-volume surgeons had a fivefold OR in the presence of phacodonesis and a fourfold OR in the case of posterior polar cataract. Finally, the low- and high-volume groups had their highest complication rates in the cumulative four and five risk factors, respectively. Conclusion In the presence of advanced age, mature cataracts, phacodonesis and posterior polar cataract, the complication rates appear to be higher for the less experienced surgeons. Meticulous preoperative assessment with detailed documentation of each patient’s risk factors can result in fewer complications. The medical complexity of each case can be used as indicator of whether a more experienced surgeon should perform the surgery or not.


  • Open Access

    Descemet Stripping Endothelial Keratoplasty for Congenital Aniridia: An Interesting and Challenging Story

    by Ioannis Athanasiadis, Michael Tsatsos, Nikolaos Ziakas

    Congenital aniridia is a rare condition affecting a wide range of ocular structures, from the ocular surface to the retina. We present the case of a 59-year-old woman with PAX6- and WTI-negative congenital aniridia who developed aniridia-associated keratopathy and progressive endothelial dysfunction with corneal decompensation after cataract surgery. The patient underwent successful ultrathin Descemet stripping endothelial keratoplasty. Despite the challenges faced with an unstable iridolenticular diaphragm, we were pleasantly surprised to see improvement not only of corneal edema and endothelial function but also of the whole cornea, including anterior corneal anatomy and appearance. In conclusion, endothelial transplantation in a patient with aniridia resulted in improvement of all the corneal structures from the endothelium to the stroma, epithelium, and possibly even the ocular surface.


  • Ocular parameter changes after phacoemulsification in pseudoexfoliative eyes: case–control study

    by Ioannis Kassos, Argyrios MD Tzamalis, Maria Dermenoudi, Artemis Md Matsou, Spyridon Md Koronis, Nikolaos Ziakas, Eleftherios Anastasopoulos

    Purpose: To assess changes of angle morphometric parameters, anterior chamber depth (ACD), intraocular pressure (IOP), and endothelial cell density (ECD) after uneventful phacoemulsification in eyes with pseudoexfoliation syndrome (PEX) compared with those in eyes without PEX and to evaluate the effect of these changes on effective lens position and postoperative refraction. Setting: Papageorgiou Hospital, Thessaloniki, Greece. Design: Prospective case–control study. Methods: Angle opening distance, trabecular-iris space area, and scleral spur angle width were measured using anterior segment optical coherence tomography. ACD was assessed using IOLMaster and ECD using specular microscopy. All parameters were evaluated at baseline and 2 months postoperatively. Results: 42 patients (42 eyes) with PEX and 39 patients (39 eyes) without PEX who underwent uneventful phacoemulsification were enrolled. All angle parameters and ACD increased significantly after phacoemulsification in both groups (P < .001), with no statistically significant difference between them (P > .05). Percentile change in ACD was greater in PEX eyes (P = .017). Regarding the mean refractive prediction error, no statistically significant differences were found between the study groups (P = .68). A statistically significant trend toward hyperopic shift was noted in the PEX group (P = .039). IOP and ECD diminished postoperatively in both groups, with no statistically significant difference between the study groups (P = .09 and P = .22, respectively). Conclusions: PEX, compared with non-PEX eyes, demonstrated a greater anterior chamber deepening and a hyperopic shift after phacoemulsification. These could be related to the zonular laxity in eyes with PEX and imply that PEX eyes may require a modified target refraction to achieve the desired refractive outcome.


  • Reliability of Refraction, Keratometry, and Intraocular Pressure Measurements with an Automated All‐in‐one Device

    by Argyrios Tzamalis, Chara Tsiampali, Efthymia Md Prousali, Asimina Mataftsi, Nikolaos Ziakas, Myron Kynigopoulos

    SIGNIFICANCE: This study explores the reliability of TonoRef II (Nidek, Tokyo, Japan), which represents a simple tool to obtain rapid refractometry and tonometry measurements. The present device demonstrates very high repeatability of refraction and intraocular pressure (IOP) readings as compared with subjective measurements and a higher concordance of IOP readings to Goldmann application tonometry (GAT). PURPOSE: This study aimed to evaluate the repeatability of measurements acquired with the Autorefractometer/Keratometer/Tonometer TonoRef II and assess their agreement to subjective measurements and readings of other established devices. METHODS: In a cross‐sectional study, 54 eyes of 54 healthy subjects were enrolled. Each subject underwent five measurements with the TonoRef II, three measurements with the Canon RK‐F1 Autorefractor Keratometer (Canon Europe NV, Amstelveen, the Netherlands), three IOP measurements with the Canon TX‐F Noncontact Tonometer (Canon Inc., Tokyo, Japan), three measurements with GAT, and a thorough subjective refraction. Repeatability coefficient ( r ), intraclass correlation coefficient (ICC), and Bland‐Altman plots were used to evaluate repeatability of readings and agreement to the subjective values. RESULTS: TonoRef II showed high repeatability (ICC >0.9) in all parameters tested (sphere, r = 0.157; cylinder, r = 0.196; IOP, r = 2.653). A strong correlation was found between TonoRef and Canon instruments ( P <. 001 in all parameters). Mean differences and limits of agreement (mean ± 1.96 standard deviation) were −0.01 ± 0.69 D, −0.11 ± 0.7 D, and 2.1 ± 3.4 mmHg for sphere, cylinder, and IOP, respectively. Both autorefractors achieved a very good to excellent agreement to the values obtained with the subjective refraction for most of the parameters tested, without any significant difference to each other ( P >. 05). Intraocular pressure measurements of TonoRef II showed higher agreement to the GAT values compared with those obtained with the Canon tonometer (ICC, 0.9114 and 0.7002, respectively; P <. 001). CONCLUSIONS: Intraocular pressure and refraction readings acquired with TonoRef II demonstrate very high repeatability and agreement to the subjective measurements. Regarding IOP evaluation, TonoRef II shows higher concordance to GAT compared with another established noncontact tonometer.


  • Iridocorneal angle assessment in children with spontaneously regressed retinopathy of prematurity

    by Efthymia Prousali, Anna Dastiridou, Anna-Bettina Haidich, Argyrios Tzamalis, Nikolaos Ziakas, Asimina Mataftsi

    Purpose To assess anterior segment anatomic parameters in school-aged children with spontaneously regressed retinopathy of prematurity (sr-ROP) and in children born preterm without ROP history (preT). Methods sr-ROP and preT children were compared with healthy, born at term children (control group). Biometric characteristics were measured with the IOLMaster. Iridocorneal angle structure was evaluated using Visante AS-OCT, and angle opening distance, trabecular iris space area and scleral spur angle were calculated. Best-corrected visual acuity (BCVA) was measured with the ETDRS chart. Results We examined 22 eyes of 11 children with sr-ROP, 26 eyes of 13 preT children and 24 eyes of 12 healthy controls, with a median age of 8 years. sr-ROP children exhibited worse mean BCVA and reduced AL compared to controls (p = 0.001 and p = 0.007, respectively). A narrower iridocorneal angle was found in sr-ROP compared to the preT and the control groups. Preterm children were found to have similar anterior chamber angle metrics compared to the full-term control group. Conclusion In this study, school-aged children with a history of sr-ROP had narrower angles compared to preterm- and term-born children. AS-OCT demonstrated structural differences of the iridocorneal angle in sr-ROP, possibly reflecting a mild developmental arrest of the anterior segment.


  • Open Access

    Reoperations After Cataract Surgery: Is the Incidence Predictable Through a Risk Factor Stratification System?

    by Eirini Oustoglou, Argyrios Tzamalis, Ioannis Mamais, Maria Dermenoudi, Konstantinos Tsaousis, Nikolaos Ziakas, Ioannis Tsinopoulos

    The objective of the study was to quantify the number of procedures needed to achieve the best possible surgical outcome, depending on the number and type of risk factors identified. Two independent observers reviewed the medical records of 1,502 patients who underwent phacoemulsification surgery, during a two-year period (January 1, 2014 to December 31, 2015). Preoperative risk factors were documented according to the stratification system used. Based on the total risk score, each case was allocated to one of four risk groups with 0, 1-2, 3-5, and >6 total risk factors, respectively. All qualitative and quantitative characteristics were gathered and included in a multivariate analysis. A total of 1,792 eyes were included. Αge over 88 years, low cooperation ability with the patient, and surgeries performed by residents tended to have more often complications, while white/intumescent cataract, iridodonesis/phacodonesis, α1 blockers intake, and male gender are risk factors positively associated with more than one surgery. Risk factors tend to be prognostic for possible intraoperative complications. The number of procedures needed for the best possible surgical outcome seems to depend on these preoperative risk factors. A stratification method increases the level of awareness of the surgeon, and therefore may decrease the number of complications and even procedures while enhancing the "safe" practice and skills of residents.


  • Ease of Hydrodissection during Phacoemulsification: A Comparison between Patients with and Those without Exfoliation Syndrome

    by Konstantina N. Sorkou, Ioannis T. Tsinopoulos, Konstantinos T. Tsaousis, Athanasios Karamitsos, Soultana Meditskou, Nikolaos Ziakas, Maria Eleni Manthou

    Background: Exfoliation syndrome (XFS), which is associated with increased surgical complications during phacoemulsification, has a relatively high incidence in Greece. Multiannual surgical experience in XFS patients has led to the clinical observation that hydrodissection occurs more easily in XFS patients. Objective: To compare the ease of hydrodissection between cataract patients with and those without XFS. Methods: One hundred and fifteen patients with senile cataract were included in the study. Forty-two of them had XFS. All patients underwent uneventful phacoemulsification by the same surgeon. For hydrodissection, three 1-mL insulin syringes were filled with 0.5 mL balanced salt solution (BSS). Sequentially, each one was quickly and continuously injected underneath the 3, 6, and 9 o’clock positions of the anterior lens capsule. If lens mobilization was achieved with this procedure, hydrodissection was characterized as “easy.” Results: The two groups were matched for age, gender, the biomicroscopic type of cataract, and the presence of diabetes mellitus. Glaucoma occurred more often among the XFS patients (p = 0.002). In 39 of the 42 exfoliation patients (92.8%), “easy” hydrodissection was recorded. In the control group, the corresponding number was 47 out of 73 (64.3%). The two groups differed significantly (p = 0.001). Conclusions: Hydrodissection was more easily performed on the XFS patients than on the controls. This finding could be related to the extensive ultrastructural subepithelial alterations of the anterior lens capsule in XFS, as recently described in electron microscopy studies. We suggest that less BSS can be used for hydrodissection in XFS patients during phacoemulsification.