Adaptive Algorithm for Motion Artifacts Removal in Wearable Biomedical Sensors During Physical Exercise
- 27 March 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9491-9499
Abstract
Objective: Motion artifacts (MA) are significant sources of noise in the wearable devices that are used to collect biological information from the human body. Photoplethysmography (PPG) is an example of the sensors embedded in many of these devices. PPG signals are highly influenced by MA, especially when the motion involves the organ that the PPG sensor is attached to. The aim of this paper is to build an adaptive algorithm and multiresolution analysis technique to denoise the raw PPG signals, suppress the MAs and accurately estimate the HR as an example of MA suppression in the wearable devices. The challenge here is to find the right selection considering high accuracy and low-computational complexity. Methods: Discrete wavelet transform recursive inverse (DWT-RI) adaptive filter algorithm in addition to multiresolution analysis is implemented to suppress MAs and estimate the HR using the simultaneously recorded accelerations in the three dimensions as reference signals for the adaptive algorithm. Results: The proposed algorithm has a low computational cost and results in an absolute average error of 1.17 beats per minute (BPM) when tested on 12 subjects from a well-known database for this purpose. The performance of the proposed algorithm is compared to the other existing methods in literature used for noise removal and motion artifact suppression. Conclusion: DWT-RI adaptive algorithm can successfully suppress motion artifacts in PPG signals with a low computational complexity and outperforms several alternatives in terms of the average absolute error.Keywords
This publication has 39 references indexed in Scilit:
- Photoplethysmography-Based Heart Rate Monitoring Using Asymmetric Least Squares Spectrum Subtraction and Bayesian Decision TheoryIEEE Sensors Journal, 2015
- Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device2015
- Introduction to Biomedical Signals2015
- Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum ReconstructionIEEE Transactions on Biomedical Engineering, 2015
- VLSI Wavelet Based Denoising of PPG SignalProcedia Computer Science, 2015
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- Wearable Photoplethysmographic Sensors—Past and PresentElectronics, 2014
- A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic BiosensorsIEEE Journal of Biomedical and Health Informatics, 2013
- Recursive inverse adaptive algorithm: a second-order version, a fast implementation technique, and further resultsSignal, Image and Video Processing, 2013
- Motion Artifact Reduction in Photoplethysmography Using Independent Component AnalysisIEEE Transactions on Biomedical Engineering, 2006