Bahaa Al-Sheikh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bahaa Al-Sheikh has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Lama Bou Farah
Lebanese German University
1 shared publication - Mohammad Al-Rabayah
American University of the Middle East
1 shared publication - Samer Alabed
German Jordanian university
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (5) , 3831-3840
Sinusoidal modelling for efficient source coding of phonocardiogram signals in cardiac monitoring devices
This study focuses on developing an efficient and cost-effective approach for compressing Phonocardiogram (PCG) signals without compromising their quality. The method utilizes two data compression techniques, capturing heart sounds and transforming them into the frequency domain to extract essential features such as frequency, phase, and amplitude peaks. The compressed signals are subsequently reconstructed to faithfully replicate the original heart sounds. The findings contribute to advancements in biomedical signal processing and compression methodologies, with potential applications in telemedicine and remote sustainable healthcare systems. Compressed PCG signals enable real-time remote consultations and continuous cardiac health monitoring, particularly in underserved regions with limited medical resources. This research holds significant potential for improving access to cardiovascular healthcare and promoting overall health and well-being.
- 1 October 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (5) , 3831-3840
Open AccessSinusoidal modelling for efficient source coding of phonocardiogram signals in cardiac monitoring devices
This study focuses on developing an efficient and cost-effective approach for compressing Phonocardiogram (PCG) signals without compromising their quality. The method utilizes two data compression techniques, capturing heart sounds and transforming them into the frequency domain to extract essential features such as frequency, phase, and amplitude peaks. The compressed signals are subsequently reconstructed to faithfully replicate the original heart sounds. The findings contribute to advancements in biomedical signal processing and compression methodologies, with potential applications in telemedicine and remote sustainable healthcare systems. Compressed PCG signals enable real-time remote consultations and continuous cardiac health monitoring, particularly in underserved regions with limited medical resources. This research holds significant potential for improving access to cardiovascular healthcare and promoting overall health and well-being.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9491-9499
Adaptive Algorithm for Motion Artifacts Removal in Wearable Biomedical Sensors During Physical Exercise
Objective: Motion artifacts (MA) are significant sources of noise in the wearable devices that are used to collect biological information from the human body. Photoplethysmography (PPG) is an example of the sensors embedded in many of these devices. PPG signals are highly influenced by MA, especially when the motion involves the organ that the PPG sensor is attached to. The aim of this paper is to build an adaptive algorithm and multiresolution analysis technique to denoise the raw PPG signals, suppress the MAs and accurately estimate the HR as an example of MA suppression in the wearable devices. The challenge here is to find the right selection considering high accuracy and low-computational complexity. Methods: Discrete wavelet transform recursive inverse (DWT-RI) adaptive filter algorithm in addition to multiresolution analysis is implemented to suppress MAs and estimate the HR using the simultaneously recorded accelerations in the three dimensions as reference signals for the adaptive algorithm. Results: The proposed algorithm has a low computational cost and results in an absolute average error of 1.17 beats per minute (BPM) when tested on 12 subjects from a well-known database for this purpose. The performance of the proposed algorithm is compared to the other existing methods in literature used for noise removal and motion artifact suppression. Conclusion: DWT-RI adaptive algorithm can successfully suppress motion artifacts in PPG signals with a low computational complexity and outperforms several alternatives in terms of the average absolute error.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9491-9499
Adaptive Algorithm for Motion Artifacts Removal in Wearable Biomedical Sensors During Physical Exercise
Objective: Motion artifacts (MA) are significant sources of noise in the wearable devices that are used to collect biological information from the human body. Photoplethysmography (PPG) is an example of the sensors embedded in many of these devices. PPG signals are highly influenced by MA, especially when the motion involves the organ that the PPG sensor is attached to. The aim of this paper is to build an adaptive algorithm and multiresolution analysis technique to denoise the raw PPG signals, suppress the MAs and accurately estimate the HR as an example of MA suppression in the wearable devices. The challenge here is to find the right selection considering high accuracy and low-computational complexity. Methods: Discrete wavelet transform recursive inverse (DWT-RI) adaptive filter algorithm in addition to multiresolution analysis is implemented to suppress MAs and estimate the HR using the simultaneously recorded accelerations in the three dimensions as reference signals for the adaptive algorithm. Results: The proposed algorithm has a low computational cost and results in an absolute average error of 1.17 beats per minute (BPM) when tested on 12 subjects from a well-known database for this purpose. The performance of the proposed algorithm is compared to the other existing methods in literature used for noise removal and motion artifact suppression. Conclusion: DWT-RI adaptive algorithm can successfully suppress motion artifacts in PPG signals with a low computational complexity and outperforms several alternatives in terms of the average absolute error.