Accuracy of robot-assisted pedicle screw insertion in adolescent idiopathic scoliosis: is triggered electromyographic pedicle screw stimulation necessary?
Authors:
- 1 June 2018
- journal article
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 4 (2) , 187-194
Abstract
Background: Screw malpositioning is an identifiable cause of intraoperative neurophysiologic changes. Although triggered screw electromyography (t-EMG) has been found to exhibit high sensitivity for identifying malpositioned screws, no previous study has assessed the utility of combining t-EMG with robotic-assisted pedicle screw placement for identifying malpositioned screws. We sought to evaluate the utility of t-EMG used in combination with robotic-assisted pedicle screw placement for identifying malpositioned screws in patients with adolescent idiopathic scoliosis (AIS). Methods: Patients undergoing robotic-assisted posterior spinal fusion with pedicle screw fixation for AIS underwent retrospective review from a single surgeons prospectively collected database. Preoperative demographic data and curve characteristics were recorded. Computed tomography (CT) scans were reviewed, measuring pedicle width and classifying pedicle morphology using the channel classification system. Pedicle data was compared against intra-operative t-EMG data, with a minimal threshold of 8 mA used for screw removal and screw path examination and the rate of screw re-direction recorded. All pedicle screws were verified using image intensification. Results: Forty-nine patients (11 males, 38 females, average age 14.49 years) with an average curve magnitude of 51 degrees and placement of 844 pedicle screws to attain an average curve correction of 67.7%. The incidence of an absent pedicle (type C or D morphology) was 2%. Overall, 24 screws (2.8%) were identified with an abnormal t-EMG threshold. All screws were found to have an intact medial wall upon probing and were reinserted without re-direction. No patient or curve characteristic was predictive of abnormal t-EMG amplitude but smaller pedicles correlated with smaller amplitudes. Conclusions: With precise pre-operative planning, robotic-assisted pedicle screw placement has shown to be a safe and effective method in treating AIS patients as shown by the lack of medial pedicle breach and malpositioned screws. We found no evidence to support combined use of t-EMG for identifying medially malpositioned screws.Keywords
This publication has 30 references indexed in Scilit:
- Clinical Pedicle Screw Accuracy and Deviation From Planning in Robot-Guided Spine SurgerySpine, 2015
- Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentationEuropean Spine Journal, 2015
- Best Practices in Intraoperative Neuromonitoring in Spine Deformity Surgery: Development of an Intraoperative Checklist to Optimize ResponseSpine Deformity, 2014
- Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparisonJournal of Neurosurgery: Spine, 2014
- Analysis of CT-based Navigation System for Pedicle Screw PlacementOrthopedics, 2012
- Safe Pedicle Screw Placement in Thoracic Scoliotic Curves Using t-EMGSpine, 2012
- Stepwise Methodology for Plain Radiographic Assessment of Pedicle Screw Placement: A Comparison With Computed TomographyJournal of Spinal Disorders & Techniques, 2006
- Electrical Stimulation for Intraoperative Evaluation of Thoracic Pedicle Screw PlacementSpine, 2003
- Adolescent idiopathic scoliosis: a new classification to determine extent of spinal arthrodesis.2001
- Morphometric Analysis of Thoracic and Lumbar Vertebrae in Idiopathic ScoliosisSpine, 2000