Forces achieved by different material and type of intrusion arches applied in different horizontal levels
Open Access
- 24 January 2024
- journal article
- Published by Universitas Airlangga in Dental Journal (Majalah Kedokteran Gigi)
- Vol. 57 (1) , 9-14
Abstract
Background: Intrusion is one of the most needed movements in orthodontics. It is possible to achieve this with arch wires, miniscrews, and bite-blocks. Purpose: This in vitro study aimed to evaluate forces achieved by different types of intrusion arches made of different materials and anchored in two different horizontal levels by either miniscrews or molar teeth. Methods: An upper jaw typodont was applied different types of intrusion arches: intrusion and utility arches, made of different materials (nitinol, beta III titanium, stainless steel) and different wire sizes (0.016” x 0.022” and 0.017” x 0.025”) to the incisors, both anchoring from molars and miniscrews respectively. Each application was measured by a Correx gauge. Each wire was applied to both the auxiliary slot of the triple tube and the slot in the head of the miniscrew. One-way analysis of variance (ANOVA), Tukey's HSD test, and a paired two-sample t-test were used to analyze the data. Results: In the intrusion arches, the main effect of the material was found to be statistically significant on force values (p = 0.034) while the main effect of the size was not found statistically significant on force values (p = 0.083). In the utility arches, both the main effect of the material (p = 0.067) and the size (p = 0.140) were not found to be statistically significant on force values. Conclusion: Regardless of the anchorage unit level and size, nitinol was the material that applied the lowest forces among all materials. The material is the most effective factor in the force generated, while the anchorage unit level is the least.Keywords
This publication has 18 references indexed in Scilit:
- Management of impacted maxillary canine with surgical exposure and alignment by orthodontic treatmentDental Journal (Majalah Kedokteran Gigi), 2022
- Maxillary anterior root resorption in Class II/I malocclusion patients post fixed orthodontic treatmentDental Journal (Majalah Kedokteran Gigi), 2020
- Effect of maxillary incisors, lower lip, and gingival display relationship on smile attractivenessAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2020
- Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)Dental Press Journal of Orthodontics, 2017
- Rate of intrusion of maxillary incisors in Class II Div 1 malocclusion using skeletal anchorage device and Connecticut intrusion archMedical Journal Armed Forces India, 2017
- Laypeople's perceptions of frontal smile esthetics: A systematic reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2016
- Comparative evaluation of intrusive effects of miniscrew, Connecticut intrusion arch, and utility intrusion arch – An in vivo studyJournal of Pierre Fauchard Academy (India Section), 2015
- A comparative study of different intrusion methods and their effect on maxillary incisorsJournal of Oral Biology and Craniofacial Research, 2014
- Segmented arch or continuous arch technique? A rational approachDental Press Journal of Orthodontics, 2014
- Initial arch wires for tooth alignment during orthodontic treatment with fixed appliancesCochrane Database of Systematic Reviews, 2013