Delal Dara Kılınç
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Delal Dara Kılınç has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Gülşilay Sayar
Department of Orthodontics, Faculty of Dentistry, Bahçeşehir University, Istanbul, Turkey
9 shared publications Gülşilay Sayar
Istanbul Medipol Üniversitesi
3 shared publicationsDuygu Mansız
Istanbul, Turkey
2 shared publicationsEmrah Dilaver
Istanbul Medipol Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Istanbul, Turkey
2 shared publications- Pamir Meriç
Trakya University Faculty of Dentistry, Department of Orthodontics, Edirne, Turkey
2 shared publications Ahmet Karaman
Department of Orthodontics, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey
1 shared publication
Latest Publications
- 29 December 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
The Increasing Interest in Clear Aligners in Türkiye: A Google Trends™ Analysis
Aim: This study aims to comparatively examine the public interest in clear aligners versus fixed orthodontic treatments in Türkiye. Using Google Trends™ (GT) data, the analysis seeks to identify treatment preferences and trends within the population, guiding strategic decisions in clinical and educational domains. Material and Methods: GT data for the search terms “Invisalign” and “Orthodontic brackets” in Türkiye between 2019 and 2024 were collected and normalized (0–100). Statistical analyses were conducted using IBM SPSS 21, employing parametric tests for normally distributed data and non-parametric tests otherwise. Statistical significance was set at p<0.05. Results: The findings revealed that public interest in clear aligners was significantly higher than in fixed orthodontic treatments (p<0.05). Over the years, searches for clear aligners increased by 20%, whereas searches for fixed braces decreased by 4%. These trends highlight how the advantages of aligners, including aesthetics, comfort, and convenience, influence patient preferences. Conclusion: This study reveals that interest in Invisalign treatment is increasing in Türkiye and aligns with global trends. It is recommended that clinical practices and educational curricula be adapted to incorporate these technologies. Although digital platforms offer opportunities for information access, their use should be encouraged cautiously due to concerns about misinformation and commercial influence.
- 29 December 2025
- Published by Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J), Necmettin Erbakan University in Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEUDentJ), Necmettin Erbakan
The Increasing Interest in Clear Aligners in Türkiye: A Google Trends™ Analysis
Aim: This study aims to comparatively examine the public interest in clear aligners versus fixed orthodontic treatments in Türkiye. Using Google Trends™ (GT) data, the analysis seeks to identify treatment preferences and trends within the population, guiding strategic decisions in clinical and educational domains. Material and Methods: GT data for the search terms “Invisalign” and “Orthodontic brackets” in Türkiye between 2019 and 2024 were collected and normalized (0–100). Statistical analyses were conducted using IBM SPSS 21, employing parametric tests for normally distributed data and non-parametric tests otherwise. Statistical significance was set at p<0.05. Results: The findings revealed that public interest in clear aligners was significantly higher than in fixed orthodontic treatments (p<0.05). Over the years, searches for clear aligners increased by 20%, whereas searches for fixed braces decreased by 4%. These trends highlight how the advantages of aligners, including aesthetics, comfort, and convenience, influence patient preferences. Conclusion: This study reveals that interest in Invisalign treatment is increasing in Türkiye and aligns with global trends. It is recommended that clinical practices and educational curricula be adapted to incorporate these technologies. Although digital platforms offer opportunities for information access, their use should be encouraged cautiously due to concerns about misinformation and commercial influence.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (3) , e2524157
Evaluation of reliability and reproducibility of artificial intelligence-based, computer-based and traditional manual tracing methods
Introduction: Technological developments affect every aspect of life and science, including cephalometric evaluation methods in orthodontics. Artificial-intelligence-supported mobile Internet devices provide doctors the convenience of performing necessary analyses for patients anytime and anywhere. Objective: This study aimed to compare the lateral cephalometric measurement methods of the Artificial Intelligence Tracking Method (AITM, WebCeph), Computer-Based Tracking Method (CBTM, NemoCeph), and Manual Tracking Method (MTM), to evaluate the reliability of medical technological approaches, compared to traditional methods. Methods: Two hundred fifty lateral cephalometric radiographs were evaluated using three different methods: WebCeph, NemoCeph, and manual tracing. For this purpose, ten angular (SNA, SNB, ANB, Go-Gn/SN, Occlusal Plane/SN, U1/SN, U1/NA, L1/Mandibular Plane, L1/NB, and Interincisal angle [U1/L1]) and five linear (U1/NA, L1/NB, Wits Appraisal, Ls/E Plane, and Li/E Plane) parameters were measured, and the data were statistically analyzed. Results: There was excellent reliability between the three methods in measurements of SNA, SNB, L1/NB Angle, L1/NB mm, ANB, Wits Appraisal, Ls/E Plane, Li/E Plane, Go-Gn/SN, and Occlusal Plane/SN (p<0.001 and ICC range 0.915 to 0.979). Regarding the agreement between the two measurements, there were statistically significant perfect agreements in all other parameters, except for two moderate ones. Statistically significant differences were found in almost all measured parameters between the tracing methods. Conclusion: There were significant differences in the majority of the measurement methods. Regarding reproducibility, the Interincisal Angle values showed low consistency with the AITM method, and the U1/SN values showed low consistency with both the CBTM and AITM methods.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (3) , e2524157
Open AccessEvaluation of reliability and reproducibility of artificial intelligence-based, computer-based and traditional manual tracing methods
Introduction: Technological developments affect every aspect of life and science, including cephalometric evaluation methods in orthodontics. Artificial-intelligence-supported mobile Internet devices provide doctors the convenience of performing necessary analyses for patients anytime and anywhere. Objective: This study aimed to compare the lateral cephalometric measurement methods of the Artificial Intelligence Tracking Method (AITM, WebCeph), Computer-Based Tracking Method (CBTM, NemoCeph), and Manual Tracking Method (MTM), to evaluate the reliability of medical technological approaches, compared to traditional methods. Methods: Two hundred fifty lateral cephalometric radiographs were evaluated using three different methods: WebCeph, NemoCeph, and manual tracing. For this purpose, ten angular (SNA, SNB, ANB, Go-Gn/SN, Occlusal Plane/SN, U1/SN, U1/NA, L1/Mandibular Plane, L1/NB, and Interincisal angle [U1/L1]) and five linear (U1/NA, L1/NB, Wits Appraisal, Ls/E Plane, and Li/E Plane) parameters were measured, and the data were statistically analyzed. Results: There was excellent reliability between the three methods in measurements of SNA, SNB, L1/NB Angle, L1/NB mm, ANB, Wits Appraisal, Ls/E Plane, Li/E Plane, Go-Gn/SN, and Occlusal Plane/SN (p<0.001 and ICC range 0.915 to 0.979). Regarding the agreement between the two measurements, there were statistically significant perfect agreements in all other parameters, except for two moderate ones. Statistically significant differences were found in almost all measured parameters between the tracing methods. Conclusion: There were significant differences in the majority of the measurement methods. Regarding reproducibility, the Interincisal Angle values showed low consistency with the AITM method, and the U1/SN values showed low consistency with both the CBTM and AITM methods.
- 28 May 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (6) , 614-616
Authors’ response
- 28 May 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (6) , 614-616
Authors’ response
- Top Cited Papers
- 2 February 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (5) , 546-555
Examination of the reliability and readability of Chatbot Generative Pretrained Transformer’s (ChatGPT) responses to questions about orthodontics and the evolution of these responses in an updated version
- 2 February 2024
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (5) , 546-555
Top Cited PapersExamination of the reliability and readability of Chatbot Generative Pretrained Transformer’s (ChatGPT) responses to questions about orthodontics and the evolution of these responses in an updated version
- Open Access
- 24 January 2024
- Published by Universitas Airlangga in Dental Journal (Majalah Kedokteran Gigi)
- Vol. 57 (1) , 9-14
Forces achieved by different material and type of intrusion arches applied in different horizontal levels
Background: Intrusion is one of the most needed movements in orthodontics. It is possible to achieve this with arch wires, miniscrews, and bite-blocks. Purpose: This in vitro study aimed to evaluate forces achieved by different types of intrusion arches made of different materials and anchored in two different horizontal levels by either miniscrews or molar teeth. Methods: An upper jaw typodont was applied different types of intrusion arches: intrusion and utility arches, made of different materials (nitinol, beta III titanium, stainless steel) and different wire sizes (0.016” x 0.022” and 0.017” x 0.025”) to the incisors, both anchoring from molars and miniscrews respectively. Each application was measured by a Correx gauge. Each wire was applied to both the auxiliary slot of the triple tube and the slot in the head of the miniscrew. One-way analysis of variance (ANOVA), Tukey's HSD test, and a paired two-sample t-test were used to analyze the data. Results: In the intrusion arches, the main effect of the material was found to be statistically significant on force values (p = 0.034) while the main effect of the size was not found statistically significant on force values (p = 0.083). In the utility arches, both the main effect of the material (p = 0.067) and the size (p = 0.140) were not found to be statistically significant on force values. Conclusion: Regardless of the anchorage unit level and size, nitinol was the material that applied the lowest forces among all materials. The material is the most effective factor in the force generated, while the anchorage unit level is the least.
- 24 January 2024
- Published by Universitas Airlangga in Dental Journal (Majalah Kedokteran Gigi)
- Vol. 57 (1) , 9-14
Open AccessForces achieved by different material and type of intrusion arches applied in different horizontal levels
Background: Intrusion is one of the most needed movements in orthodontics. It is possible to achieve this with arch wires, miniscrews, and bite-blocks. Purpose: This in vitro study aimed to evaluate forces achieved by different types of intrusion arches made of different materials and anchored in two different horizontal levels by either miniscrews or molar teeth. Methods: An upper jaw typodont was applied different types of intrusion arches: intrusion and utility arches, made of different materials (nitinol, beta III titanium, stainless steel) and different wire sizes (0.016” x 0.022” and 0.017” x 0.025”) to the incisors, both anchoring from molars and miniscrews respectively. Each application was measured by a Correx gauge. Each wire was applied to both the auxiliary slot of the triple tube and the slot in the head of the miniscrew. One-way analysis of variance (ANOVA), Tukey's HSD test, and a paired two-sample t-test were used to analyze the data. Results: In the intrusion arches, the main effect of the material was found to be statistically significant on force values (p = 0.034) while the main effect of the size was not found statistically significant on force values (p = 0.083). In the utility arches, both the main effect of the material (p = 0.067) and the size (p = 0.140) were not found to be statistically significant on force values. Conclusion: Regardless of the anchorage unit level and size, nitinol was the material that applied the lowest forces among all materials. The material is the most effective factor in the force generated, while the anchorage unit level is the least.
- Open Access
- 2 June 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-22
Myofunctional orofacial examination tests: a literature review
Introduction: Myofunctional orofacial examination (MOE) is an important tool for the assessment of the stomatognathic system and orofacial functions, and the early diagnosis of orofacial myofunctional disorders. Therefore, the purpose of the study is to scan the literature and determine the most preferred test for myofunctional orofacial examination. Materials and Methods: A literature review was conducted to collect information. Pubmed and ScienceDirect database was explored by using keywords gained by MeSH (Medical Subject Headings). Results: Fifty-six studies were retrived from the search and all of the studies were screened and evaluated regarding the subject, aim, conclusions and the orofacial myofunctional examination test they used. It has been observed that traditional evaluation and inspection methods have been replaced by newer and methodological approaches in recent years. Conclusions: Although the few tests used differ, 'Orofacial Examination Test With Scores’ (OMES) was found to be the most preferred myofunctional orofacial evaluation method from ENT to cardiology.
- 2 June 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-22
Open AccessMyofunctional orofacial examination tests: a literature review
Introduction: Myofunctional orofacial examination (MOE) is an important tool for the assessment of the stomatognathic system and orofacial functions, and the early diagnosis of orofacial myofunctional disorders. Therefore, the purpose of the study is to scan the literature and determine the most preferred test for myofunctional orofacial examination. Materials and Methods: A literature review was conducted to collect information. Pubmed and ScienceDirect database was explored by using keywords gained by MeSH (Medical Subject Headings). Results: Fifty-six studies were retrived from the search and all of the studies were screened and evaluated regarding the subject, aim, conclusions and the orofacial myofunctional examination test they used. It has been observed that traditional evaluation and inspection methods have been replaced by newer and methodological approaches in recent years. Conclusions: Although the few tests used differ, 'Orofacial Examination Test With Scores’ (OMES) was found to be the most preferred myofunctional orofacial evaluation method from ENT to cardiology.
- 5 August 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (4) , e169-e175
Anamnesis and examination forms used in orthodontic clinics: A pilot study
- 5 August 2022
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 162 (4) , e169-e175
Anamnesis and examination forms used in orthodontic clinics: A pilot study
- 26 July 2022
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 123 (6) , e906-e915
Evaluation and comparison of smartphone application tracing, web based artificial intelligence tracing and conventional hand tracing methods
- 26 July 2022
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 123 (6) , e906-e915
Evaluation and comparison of smartphone application tracing, web based artificial intelligence tracing and conventional hand tracing methods
- 1 July 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (11) , 6551-6561
Do different orthodontic pliers used in bracket debonding have different effects on pain and sensitivity? A prospective split-mouth study
Objectives The assessment of whether different orthodontic pliers used in bracket debonding have different effects on pain and sensitivity experience. Materials and methods Thirty-three patients (17 females, 16 males) with metal brackets were included in the study. Compressed air and freshly melted ice water were applied to each tooth (6–6) in upper and lower arch before bracket debonding (T0), just after debonding (T1), and 1 week after debonding (T2). Bracket remover plier (BRP) and Weingart plier (WP) were used to debond brackets. A numeric rating scale (NRS) was used to assess sensitivity for each tooth at T0, T1, and T2. Tooth pain was assessed for each tooth using NRS during bracket debonding. Results Statistically higher pain scores were found in teeth U4 (upper first premolar) (p = 0.017) and L6 (lower first molar) (p = 0.026) in Weingart plier group. No statistically significant difference was found during debonding in the other teeth between groups. Statistically high sensitivity score was found at T1 time point in tooth U3 (upper canine) by applying air stimulus in Weingart plier group (p = 0.024). There was no statistically significant difference between the sensitivity scores measured at T2 time point by applying air and cold stimuli between groups. Conclusions Although the debonding pain scores were statistically significant in two teeth and the sensitivity score in one tooth, there was no clinical significance between the two pliers in terms of pain and sensitivity. Clinical relevance Both debonding pliers gave clinically similar results in terms of pain and sensitivity.
- 1 July 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (11) , 6551-6561
Do different orthodontic pliers used in bracket debonding have different effects on pain and sensitivity? A prospective split-mouth study
Objectives The assessment of whether different orthodontic pliers used in bracket debonding have different effects on pain and sensitivity experience. Materials and methods Thirty-three patients (17 females, 16 males) with metal brackets were included in the study. Compressed air and freshly melted ice water were applied to each tooth (6–6) in upper and lower arch before bracket debonding (T0), just after debonding (T1), and 1 week after debonding (T2). Bracket remover plier (BRP) and Weingart plier (WP) were used to debond brackets. A numeric rating scale (NRS) was used to assess sensitivity for each tooth at T0, T1, and T2. Tooth pain was assessed for each tooth using NRS during bracket debonding. Results Statistically higher pain scores were found in teeth U4 (upper first premolar) (p = 0.017) and L6 (lower first molar) (p = 0.026) in Weingart plier group. No statistically significant difference was found during debonding in the other teeth between groups. Statistically high sensitivity score was found at T1 time point in tooth U3 (upper canine) by applying air stimulus in Weingart plier group (p = 0.024). There was no statistically significant difference between the sensitivity scores measured at T2 time point by applying air and cold stimuli between groups. Conclusions Although the debonding pain scores were statistically significant in two teeth and the sensitivity score in one tooth, there was no clinical significance between the two pliers in terms of pain and sensitivity. Clinical relevance Both debonding pliers gave clinically similar results in terms of pain and sensitivity.
- 22 April 2022
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 123 (5) , e349-e354
Is the information about orthodontics on Youtube and TikTok reliable for the oral health of the public? A cross sectional comparative study
- 22 April 2022
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 123 (5) , e349-e354
Is the information about orthodontics on Youtube and TikTok reliable for the oral health of the public? A cross sectional comparative study