Traceability of values for catalytic activity concentration of enzymes: a Certified Reference Material for aspartate transaminase
Authors:
- Brigitte ToussaintBTBrigitte Toussaint
- Hendrik EmonsHEHendrik Emons
- Heinz G. SchimmelHSHeinz G. Schimmel
- Steffen Bossert-ReutherSBSteffen Bossert-Reuther
- Francesca CanaliasFCFrancesca Canalias
- Ferruccio CeriottiFCFerruccio Ceriotti
- Georges FérardGFGeorges Férard
- Carlo A. FerreroCFCarlo A. Ferrero
- Paul F.H. FranckPFPaul F.H. Franck
- F. Javier GellaFGF. Javier Gella
- Joseph HennyJHJoseph Henny
- Poul J. JørgensenPJPoul J. Jørgensen
- 1 January 2010
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 48 (6) , 795-803
Abstract
A new reference material for the liver enzyme aspartate transaminase (AST) (L-aspartate: 2-oxoglutarate-aminotransferase, EC 2.6.1.1), also called aspartate aminotransferase (ASAT), has been developed under the code ERM-AD457/IFCC. This certified reference material (CRM) for AST has been produced from a human type recombinant AST expressed in Escherichia coli and a buffer containing bovine serum albumin, and has been lyophilised. The homogeneity and the stability of the material have been tested and the catalytic activity concentration has been characterised by 12 laboratories using the reference procedure for AST at 37 degrees C from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The certified catalytic activity concentration and certified uncertainty of AST in the reconstituted material are (1.74+/-0.05) microkat/L or (104.6+/-2.7) U/L (with a coverage factor k=2; 95% confidence interval). Both the certified value and uncertainty are traceable to the International System of Units (SI). The material is aiming to control the IFCC reference procedure for AST at 37 degrees C, which will then be used to assign values to calibrants and control materials. The present paper highlights the scientific challenges and innovations which were encountered during the development of this new CRM.Keywords
This publication has 13 references indexed in Scilit:
- Traceability as a unique tool to improve standardization in laboratory medicineClinical Biochemistry, 2009
- Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration materialClinical Chemistry and Laboratory Medicine (CCLM), 2006
- Standardization in laboratory medicine: New challengesClinica Chimica Acta, 2005
- IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of γ-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase according to IFCC Reference Procedures at 37°CClinical Chemistry and Laboratory Medicine (CCLM), 2002
- IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate AminotransferaseClinical Chemistry and Laboratory Medicine (CCLM), 2002
- IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of EnzymesClinical Chemistry and Laboratory Medicine (CCLM), 2002
- IFCC Primary Reference Procedures for the Measurement of Catalytic Concentrations of Enzymes – the New ConceptClinical Chemistry and Laboratory Medicine (CCLM), 2002
- Establishing a Reference System in Clinical EnzymologyClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Impact of reference materials on accuracy in clinical chemistryClinical Biochemistry, 1998
- Interassay calibration as a major contribution to the comparability of results in clinical enzymologyClinical Biochemistry, 1998