Histotripsy Treatment of S. Aureus Biofilms on Surgical Mesh Samples Under Varying Pulse Durations
- 22 June 2017
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 64 (10) , 1420-1428
Abstract
Prior studies demonstrated that histotripsy generated by high-intensity tone bursts to excite a bubble cloud adjacent to a medical implant can destroy the bacteria biofilm responsible for the infection. The goal of this paper was to treat Staphylococcus aureus (S. aureus) biofilms on surgical mesh samples while varying the number of cycles in the tone burst to minimize collateral tissue damage while maximizing therapy effectiveness. S. aureus biofilms were grown on 1-cm square surgical mesh samples. The biofilms were then treated in vitro using a spherically focused transducer (1.1 MHz, 12.9-cm focal length, 12.7-cm diameter) using either a sham exposure or histotripsy pulses with tone burst durations of 3, 5, or 10 cycles (pulse repetition frequency of 333 Hz, peak compressional pressure of 150 MPa, peak rarefactional pressure of 17 MPa). After treatment, the number of colony forming units (CFUs) on the mesh and the surrounding gel was independently determined. The number of CFUs remaining on the mesh for the sham exposure (4.8 ± 0.9-log 10 ) (sample mean ± sample standard deviation-log 10 from 15 observations) was statistically significantly different from the 3-cycle (1.9 ± 1.5-log 10 ), 5-cycle (2.2 ± 1.1-log 10 ), and 10-cycle exposures (1 ± 1.5-log 10 ) with an average reduction in the number of CFUs of 3.1-log 10 . The numbers of CFUs released into the gel for both the sham and exposure groups were the same within a bound of 0.86-log 10 , but this interval was too large to deduce the fate of the bacteria in the biofilm following the treatment.Keywords
Funding Information
- National Institutes of Health (R21EB020722)
This publication has 52 references indexed in Scilit:
- Effectiveness of Denture Cleanser Associated With Microwave Disinfection and Brushing of Complete Dentures: In Vivo StudyBrazilian Dental Journal, 2013
- Minimization of treatment time for in vitro 1.1MHz destruction of Pseudomonas aeruginosa biofilms by high-intensity focused ultrasoundUltrasonics, 2012
- Mesh Infection in Ventral Incisional Hernia Repair: Incidence, Contributing Factors, and TreatmentSurgical Infections, 2011
- Transversal Stiffness and Young's Modulus of Single Fibers from Rat Soleus Muscle Probed by Atomic Force MicroscopyBiophysical Journal, 2010
- Noninvasive Thrombolysis Using Pulsed Ultrasound Cavitation Therapy – HistotripsyUltrasound in Medicine & Biology, 2009
- Parastomal hernia: complications of extra-peritoneal onlay mesh placementHernia, 2009
- Size Measurement of Tissue Debris Particles Generated from Pulsed Ultrasound Cavitational Therapy – HistotripsyUltrasound in Medicine & Biology, 2009
- Treatment of biofilm infections on implants with low-frequency ultrasound and antibioticsAmerican Journal of Infection Control, 2005
- Laparoscopic incisional and ventral hernia repair: Complications?how to avoid and handleHernia, 2004
- Review of the Use of Statistics in Infection andImmunityInfection and Immunity, 2003