Comparison of SPACE and 3D TSE MRCP at 1.5T Focusing on Difference in Echo Spacing
- 1 January 2009
- journal article
- research article
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 8 (3) , 101-105
Abstract
Purpose: We compared the image quality of SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions) and conventional 3D turbo spin echo (TSE) magnetic resonance cholangiopancreatography (MRCP) at 1.5 tesla with regard to difference in echo spacing. Methods: Twenty healthy volunteers prospectively underwent navigator-triggered SPACE and 3D TSE MRCP at 1.5T with identical parameters, except for echo spacing. Quantitative analyses of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), relative contrast, and contour sharpness index of each segment of the pancreaticobiliary tree were compared using paired t-tests. Qualitative analyses on a 5-point scale (1, excellent; 5, poor) scored by 2 independent radiologists were compared using Wilcoxon signed-rank test. Results: The SNR, CNR, and contour sharpness index of each segment were significantly better for the SPACE sequence than 3D TSE (P0.05). Conclusion: We verified SPACE MRCP quantitatively superior to conventional 3D TSE MRCP at 1.5T as a result of shortening of echo spacing.Keywords
This publication has 16 references indexed in Scilit:
- High‐spatial‐resolution three‐dimensional MR cholangiography using a high‐sampling‐efficiency technique (SPACE) at 3T: Comparison with the conventional constant flip angle sequence in healthy volunteersJournal of Magnetic Resonance Imaging, 2008
- Navigator‐triggered prospective acquisition correction (PACE) technique vs. conventional respiratory‐triggered technique for free‐breathing 3D MRCP: An initial prospective comparative study using healthy volunteersJournal of Magnetic Resonance Imaging, 2008
- N/2 Ghosting Artifacts: Elimination at 3.0-T MR Cholangiography with SPACE Pulse SequenceRadiology, 2008
- Frequency of Common Bile Duct Motion Artifacts Caused by Inferior Vena Cava Pulsation on Magnetic Resonance CholangiopancreatographyMagnetic Resonance in Medical Sciences, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correctionMagnetic Resonance Imaging, 2005
- The utility of MRCP in preoperative mapping of biliary anatomy in adult‐to‐adult living related liver transplant donorsJournal of Magnetic Resonance Imaging, 2004
- Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary treeGastrointestinal Endoscopy, 2002
- Detection of Choledocholithiasis with MR Cholangiography: Comparison of Three-dimensional Fast Spin-Echo and Single- and Multisection Half-Fourier Rapid Acquisition with Relaxation Enhancement SequencesRadiology, 2000
- Mr cholangiopancreatography: Comparison between two-dimensional fast spin-echo and three-dimensional gradient-echo pulse sequencesJournal of Magnetic Resonance Imaging, 1995