Dose estimation in X-ray backscatter imaging with Timepix3 and TLD detectors
Open Access
- 1 May 2023
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (05) , P05042
Abstract
Nowadays, the detection of backscatter X-rays has become an essential part of road security scanners, where individuals are at risk of an accidental exposure to the pulsed photon radiation fields generated by the devices that implement this technique. Dose to soft-tissue measurements of a pulsed radiation field generated by a commercial cargo X-ray backscattering device are presented using a Timepix3 detector. To accurately estimate the imparted dose, the energy spectrum of a backscattering cargo scanner is measured with a thick CdZnTe hybrid semiconductor pixel detector. The deconvolution of this measured spectrum is performed and the contributions to the dose are calculated by means of the mass energy-absorption coefficients for soft-tissue. This methodology was assessed through a Monte-Carlo simulation, together with verification measurements using thermoluminescent detectors (TLDs) as a standard dosimetry system. Measurements of direct irradiation, for a 30 s scan with the device at 2 m from the detector, yielded a dose of (4.9 ± 0.7) μGy and (3.6 ± 0.3) μGy for the Timepix3 and TLDs, respectively. In a simulated cargo environment, with the detector behind a 1 mm thick steel wall, 30 s scan time, and 2 m source to detector distance, the dose measured by the Timepix3 was (1.7 ± 0.1) μGy, while for the TLDs (1.4 ± 0.6) μGy, showing that the proposed methodology has a similar response as compared to a standard dosimetry system.Keywords
This publication has 41 references indexed in Scilit:
- Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ionsRadiation Measurements, 2013
- The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imagingJournal of Instrumentation, 2013
- Pixel detector Timepix operated in pile-up mode for pulsed imaging with ultra-soft X-raysJournal of Instrumentation, 2012
- Bayesian deconvolution as a method for the spectroscopy of X-rays with highly pixelated photon counting detectorsJournal of Instrumentation, 2012
- Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectorsRadiation Protection Dosimetry, 2011
- Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectorsJournal of Instrumentation, 2011
- Deficiencies of active electronic radiation protection dosemeters in pulsed fieldsRadiation Protection Dosimetry, 2009
- Determination of ambient and personal dose equivalent for personnel and cargo security screeningRadiation Protection Dosimetry, 2006
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982
- The Use of "Effective" Energy to Calculate Absorbed DosePhysics in Medicine & Biology, 1970