Juan Sebastián Useche Parra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juan Sebastián Useche Parra has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Simon Procz
Freiburg Materials Research Center, Albert-Ludwigs Universität Freiburg, Stefan-Meier St. 21, 79104 Freiburg im Breisgau, Germany
5 shared publications - Gerardo Roque
Freiburg Materials Research Center, Albert-Ludwigs Universität Freiburg, Stefan-Meier St. 21, 79104 Freiburg im Breisgau, Germany
4 shared publications - Michael Fiederle
Freiburg Materials Research Center (FMF) University of Freiburg Stefan‐Meier‐Str. 21 79104 Freiburg Germany
4 shared publications - Michael Kilian Schuetz
Freiburg Materials Research Center, Albert-Ludwigs Universität Freiburg, Stefan-Meier St. 21, 79104 Freiburg im Breisgau, Germany
4 shared publications - Carlos Avila
Universidad de los Andes
3 shared publications - Edilio Steven Cely Iza
Universidad de los Andes
3 shared publications
Latest Publications
- Open Access
- 5 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (7) , 3550
Energy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility because strong attenuation lowers contrast, while conventional rhodium (Rh) K-edge filtering suppresses part of the high-energy spectral tail. This study presents a Monte Carlo framework for spectroscopic mammography using a voxelated 1 mm thick cadmium telluride (CdTe) sensor and a first-order detector interaction model to evaluate energy-dependent image quality. The model reproduces fluorescence and inter-voxel energy redistribution in CdTe, but not the full detector chain, and remains idealized with respect to charge transport, carrier collection, threshold dispersion, and pile-up. Energy-resolved simulations in the 10–50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and to form integrated-spectrum (IS) images for four tested spectra. For the dense-breast calcium hydroxyapatite (HA) speck detection task considered here, and under the present simulation assumptions, replacing the standard 28 kVp + 50 μm Rh spectrum with 28 kVp + 1 mm Al increased the simulated IS image CNR by 23.11%, with an approximately 5% increase in estimated primary-incident air kerma at the phantom entrance plane. Preliminary experimental implant-phantom images were included as a qualitative feasibility check, showing a trend consistent with simulations. Within the limits of this task-specific simulation, the results suggest that preserving the transmitted high-energy tail can improve HA speck visibility for the present 1 mm CdTe photon-counting detector, with the 28 kVp + 1 mm Al spectrum outperforming the other tested cases.
- 5 April 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (7) , 3550
Open AccessEnergy-Resolved CNR Performance in Dense-Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility because strong attenuation lowers contrast, while conventional rhodium (Rh) K-edge filtering suppresses part of the high-energy spectral tail. This study presents a Monte Carlo framework for spectroscopic mammography using a voxelated 1 mm thick cadmium telluride (CdTe) sensor and a first-order detector interaction model to evaluate energy-dependent image quality. The model reproduces fluorescence and inter-voxel energy redistribution in CdTe, but not the full detector chain, and remains idealized with respect to charge transport, carrier collection, threshold dispersion, and pile-up. Energy-resolved simulations in the 10–50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and to form integrated-spectrum (IS) images for four tested spectra. For the dense-breast calcium hydroxyapatite (HA) speck detection task considered here, and under the present simulation assumptions, replacing the standard 28 kVp + 50 μm Rh spectrum with 28 kVp + 1 mm Al increased the simulated IS image CNR by 23.11%, with an approximately 5% increase in estimated primary-incident air kerma at the phantom entrance plane. Preliminary experimental implant-phantom images were included as a qualitative feasibility check, showing a trend consistent with simulations. Within the limits of this task-specific simulation, the results suggest that preserving the transmitted high-energy tail can improve HA speck visibility for the present 1 mm CdTe photon-counting detector, with the 28 kVp + 1 mm Al spectrum outperforming the other tested cases.
- Open Access
- 26 February 2026
- Published by MDPI AG in Preprints.org
Energy-Resolved CNR Performance in Dense Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility due to strong attenuation, while conventional rhodium (Rh) K-edge filtering typically suppresses high-energy photons. This study presents a Monte Carlo-based simulation and optimization framework for spectroscopic mammography using a voxelated Cadmium Telluride (CdTe) sensor, enabling quantitative evaluation of energy-dependent image quality. The system accurately simulates sensor fluorescence and inter-voxel energy redistribution, enabling direct comparability with real-world performance. Energy-resolved simulations in the 10-50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and identify optimal spectral regions and filter configurations. Replacing the standard Rh filter with aluminum (Al) filtration increased CNR by more than 23% with only a ~5% increase in entrance surface dose (ESD), significantly improving the visibility of hydroxyapatite microcalcifications, even behind dense tissue or implants. The shown work demonstrates practical guidelines and analysis for energy-resolved imaging optimizations obtained from simulations. The results imply that spectroscopic photon-counting detectors and methods can enhance dense-breast mammography image quality while maintaining low patient dose.
- 26 February 2026
- Published by MDPI AG in Preprints.org
Open AccessEnergy-Resolved CNR Performance in Dense Breast and Implant X-Ray Mammography Using a CdTe Photon-Counting Detector: A Monte Carlo Study
X-ray imaging of dense breasts and breast implants often suffers from reduced lesion visibility due to strong attenuation, while conventional rhodium (Rh) K-edge filtering typically suppresses high-energy photons. This study presents a Monte Carlo-based simulation and optimization framework for spectroscopic mammography using a voxelated Cadmium Telluride (CdTe) sensor, enabling quantitative evaluation of energy-dependent image quality. The system accurately simulates sensor fluorescence and inter-voxel energy redistribution, enabling direct comparability with real-world performance. Energy-resolved simulations in the 10-50 keV range were used to compute spectroscopic contrast-to-noise ratio (CNR) curves and identify optimal spectral regions and filter configurations. Replacing the standard Rh filter with aluminum (Al) filtration increased CNR by more than 23% with only a ~5% increase in entrance surface dose (ESD), significantly improving the visibility of hydroxyapatite microcalcifications, even behind dense tissue or implants. The shown work demonstrates practical guidelines and analysis for energy-resolved imaging optimizations obtained from simulations. The results imply that spectroscopic photon-counting detectors and methods can enhance dense-breast mammography image quality while maintaining low patient dose.
- Open Access
- 30 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015013
CNR enhancement in breast implant phantoms via spectral x-ray imaging
The limited visibility of breast lesions underlying silicone implants hampers the early detection of breast cancer-like features, highlighting the need for imaging methods that improve contrast behind implants. The present study investigates, both computationally and experimentally, the feasibility of combining spectrum optimization and material decomposition to enhance the contrast-to-noise ratio (CNR) of micro-calcifications in mammographic phantoms with breast implants. The goal is to reconstruct an image with improved CNR by using recovered energy-independent maps of two reference materials and applying the Beer–Lambert equation to the energy bin with the highest identified CNR. The computational study evaluates the approach using aluminum oxide and hydroxyapatite micro-calcifications embedded in standard-density breast tissue and partially obscured by silicone breast implants of four different thicknesses. Energy-bin images are generated from a simulated monochromatic x-ray source and weighted using four Tungsten polychromatic spectra with an additional filter: aluminum (1 mm) at three voltages and rhodium (0.05 mm) at 28 kVp. The experimental study independently assesses the same approach using aluminum oxide micro-calcifications within the Mammo-156 phantom, partially covered by a 250 cc compressed silicone implant. Polymethyl methacrylate slabs are added to simulate a 5 cm-thick breast. The experimental setup consists of a Tungsten micro-focus x-ray source and a hybrid photon counting detector Timepix3, which enables the acquisition of energy bin images and the estimation of entrance radiation dose. Exposure time is adjusted to achieve an entrance radiation dose of approximately 4 mGy for each spectrum, which is a typical value used in mammography. Simulation results demonstrate an enhancement in CNR in the reconstructed images compared with both the input energy-bin images with the highest CNR and the energy-weighted images, for both types of micro-calcifications and in both regions-inside and outside the implant-across all implant thicknesses. Experimental results also show the enhancement in CNR in the reconstructed images under realistic imaging conditions, for micro-calcifications in both inside and outside the implant region.
- 30 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (1) , 015013
Open AccessCNR enhancement in breast implant phantoms via spectral x-ray imaging
The limited visibility of breast lesions underlying silicone implants hampers the early detection of breast cancer-like features, highlighting the need for imaging methods that improve contrast behind implants. The present study investigates, both computationally and experimentally, the feasibility of combining spectrum optimization and material decomposition to enhance the contrast-to-noise ratio (CNR) of micro-calcifications in mammographic phantoms with breast implants. The goal is to reconstruct an image with improved CNR by using recovered energy-independent maps of two reference materials and applying the Beer–Lambert equation to the energy bin with the highest identified CNR. The computational study evaluates the approach using aluminum oxide and hydroxyapatite micro-calcifications embedded in standard-density breast tissue and partially obscured by silicone breast implants of four different thicknesses. Energy-bin images are generated from a simulated monochromatic x-ray source and weighted using four Tungsten polychromatic spectra with an additional filter: aluminum (1 mm) at three voltages and rhodium (0.05 mm) at 28 kVp. The experimental study independently assesses the same approach using aluminum oxide micro-calcifications within the Mammo-156 phantom, partially covered by a 250 cc compressed silicone implant. Polymethyl methacrylate slabs are added to simulate a 5 cm-thick breast. The experimental setup consists of a Tungsten micro-focus x-ray source and a hybrid photon counting detector Timepix3, which enables the acquisition of energy bin images and the estimation of entrance radiation dose. Exposure time is adjusted to achieve an entrance radiation dose of approximately 4 mGy for each spectrum, which is a typical value used in mammography. Simulation results demonstrate an enhancement in CNR in the reconstructed images compared with both the input energy-bin images with the highest CNR and the energy-weighted images, for both types of micro-calcifications and in both regions-inside and outside the implant-across all implant thicknesses. Experimental results also show the enhancement in CNR in the reconstructed images under realistic imaging conditions, for micro-calcifications in both inside and outside the implant region.
- Open Access
Investigations on the Performance of a 5 mm CdTe Timepix3 Detector for Compton Imaging Applications
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera. The sensor’s electron mobility–lifetime product and resistivity are studied across bias voltages ranging from −100 V to −3000 V, obtaining values of = (1.2 ± 0.1) × 10−3 cm2V−1, and two linear regions with resistivities of and . Additionally, two calibration methodologies are assessed to determine the most suitable for Compton applications, achieving an energy resolution of 16.3 for the 137Cs photopeak. The electron’s drift time in the sensor is estimated to be (122.3 ± 7.4) ns using cosmic muons. Finally, a Compton reconstruction of two simultaneous point-like sources is performed, demonstrating the detector’s capability to accurately locate radiation hotspots with a ∼51 cm resolution.Open AccessInvestigations on the Performance of a 5 mm CdTe Timepix3 Detector for Compton Imaging Applications
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera. The sensor’s electron mobility–lifetime product and resistivity are studied across bias voltages ranging from −100 V to −3000 V, obtaining values of = (1.2 ± 0.1) × 10−3 cm2V−1, and two linear regions with resistivities of and . Additionally, two calibration methodologies are assessed to determine the most suitable for Compton applications, achieving an energy resolution of 16.3 for the 137Cs photopeak. The electron’s drift time in the sensor is estimated to be (122.3 ± 7.4) ns using cosmic muons. Finally, a Compton reconstruction of two simultaneous point-like sources is performed, demonstrating the detector’s capability to accurately locate radiation hotspots with a ∼51 cm resolution. - Open Access
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (1) , 106-112
Element Identification by K-Edge Imaging Using Spectroscopic Photon Counting Detectors
The reliable identification of multiple elements in a single X-ray exposure is advantageous in various fields of interest like medicine, nondestructive materials research, homeland security, waste management, and the mining industry. Elements of interest can be identified by analyzing how an X-ray transmission spectrum correlates with the element’s K-edge. Timepix3-based photon-counting detectors offer the possibility of spectroscopic X-ray imaging, allowing to record the changes in the transmission spectrum and, consequently, for element identification. This article presents element identification using a single X-ray image recorded with a 2 mm CdZnTe Timepix3 detector. The analysis is based on the K-edge method, analyzing sharp edges in the absorption spectrum of an exposed object. The work describes the follow-up investigation of a material discrimination study utilizing several discrete energy thresholds. Single layers of 200 μm thick foils of different metals have been investigated as elements of interest. No overlaying elements or composites have been used in the absorption phantom. The method shown is limited to a specific absorption ratio inside the element, which means the influence of the absorber on the spectrum measured must result in a recognizable K-edge. Within this work, it is possible to identify eight out of nine different elements of the absorption phantom with K-edges distributed over an energy spectrum from 8 to 70 keV.
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (1) , 106-112
Open AccessElement Identification by K-Edge Imaging Using Spectroscopic Photon Counting Detectors
The reliable identification of multiple elements in a single X-ray exposure is advantageous in various fields of interest like medicine, nondestructive materials research, homeland security, waste management, and the mining industry. Elements of interest can be identified by analyzing how an X-ray transmission spectrum correlates with the element’s K-edge. Timepix3-based photon-counting detectors offer the possibility of spectroscopic X-ray imaging, allowing to record the changes in the transmission spectrum and, consequently, for element identification. This article presents element identification using a single X-ray image recorded with a 2 mm CdZnTe Timepix3 detector. The analysis is based on the K-edge method, analyzing sharp edges in the absorption spectrum of an exposed object. The work describes the follow-up investigation of a material discrimination study utilizing several discrete energy thresholds. Single layers of 200 μm thick foils of different metals have been investigated as elements of interest. No overlaying elements or composites have been used in the absorption phantom. The method shown is limited to a specific absorption ratio inside the element, which means the influence of the absorber on the spectrum measured must result in a recognizable K-edge. Within this work, it is possible to identify eight out of nine different elements of the absorption phantom with K-edges distributed over an energy spectrum from 8 to 70 keV.
- Open Access
- 1 May 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (05) , P05042
Dose estimation in X-ray backscatter imaging with Timepix3 and TLD detectors
Nowadays, the detection of backscatter X-rays has become an essential part of road security scanners, where individuals are at risk of an accidental exposure to the pulsed photon radiation fields generated by the devices that implement this technique. Dose to soft-tissue measurements of a pulsed radiation field generated by a commercial cargo X-ray backscattering device are presented using a Timepix3 detector. To accurately estimate the imparted dose, the energy spectrum of a backscattering cargo scanner is measured with a thick CdZnTe hybrid semiconductor pixel detector. The deconvolution of this measured spectrum is performed and the contributions to the dose are calculated by means of the mass energy-absorption coefficients for soft-tissue. This methodology was assessed through a Monte-Carlo simulation, together with verification measurements using thermoluminescent detectors (TLDs) as a standard dosimetry system. Measurements of direct irradiation, for a 30 s scan with the device at 2 m from the detector, yielded a dose of (4.9 ± 0.7) μGy and (3.6 ± 0.3) μGy for the Timepix3 and TLDs, respectively. In a simulated cargo environment, with the detector behind a 1 mm thick steel wall, 30 s scan time, and 2 m source to detector distance, the dose measured by the Timepix3 was (1.7 ± 0.1) μGy, while for the TLDs (1.4 ± 0.6) μGy, showing that the proposed methodology has a similar response as compared to a standard dosimetry system.
- 1 May 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (05) , P05042
Open AccessDose estimation in X-ray backscatter imaging with Timepix3 and TLD detectors
Nowadays, the detection of backscatter X-rays has become an essential part of road security scanners, where individuals are at risk of an accidental exposure to the pulsed photon radiation fields generated by the devices that implement this technique. Dose to soft-tissue measurements of a pulsed radiation field generated by a commercial cargo X-ray backscattering device are presented using a Timepix3 detector. To accurately estimate the imparted dose, the energy spectrum of a backscattering cargo scanner is measured with a thick CdZnTe hybrid semiconductor pixel detector. The deconvolution of this measured spectrum is performed and the contributions to the dose are calculated by means of the mass energy-absorption coefficients for soft-tissue. This methodology was assessed through a Monte-Carlo simulation, together with verification measurements using thermoluminescent detectors (TLDs) as a standard dosimetry system. Measurements of direct irradiation, for a 30 s scan with the device at 2 m from the detector, yielded a dose of (4.9 ± 0.7) μGy and (3.6 ± 0.3) μGy for the Timepix3 and TLDs, respectively. In a simulated cargo environment, with the detector behind a 1 mm thick steel wall, 30 s scan time, and 2 m source to detector distance, the dose measured by the Timepix3 was (1.7 ± 0.1) μGy, while for the TLDs (1.4 ± 0.6) μGy, showing that the proposed methodology has a similar response as compared to a standard dosimetry system.