Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project
Open Access
- 14 April 2026
- journal article
- research article
- Published by MDPI AG in Atmosphere
- Vol. 17 (4) , 393
Abstract
This two-week pilot study within the Horizon Europe EDIAQI project evaluated the real-life performance of portable air filtration units in two office environments (a small office and a shared kitchen) under continuous device operation and daily filter replacement. Indoor particle concentrations were monitored continuously using low-cost sensors (LCS) from three providers and supported by gravimetric measurements, while daily activity logs documented occupancy patterns, printing, cooking, and other source events together with purifier ON/OFF status. Particulate matter (PM) mass concentrations showed no systematic improvement during purifier ON periods; instead, temporal variability was dominated by indoor activities and episodic emissions, with occasional short-term peaks around filter replacement suggestive of minor resuspension. Chemical analysis provided a clearer picture: polycyclic aromatic hydrocarbons (PAHs) responded differently across fractions and compositions. Across monitored locations, high-molecular-weight PAHs in the PM1 fraction decreased during purifier ON periods (approximately 30% lower on average), whereas low-molecular-weight PAHs measured in total suspended particles (TSP) were higher during ON periods, indicating that semi-volatile fractions and activity/ventilation dynamics can outweigh simple filtration effects. Overall, the findings highlight a gap between laboratory-derived filtration performance metrics and outcomes in occupied, mixed-source indoor environments and emphasise the importance of device sizing, placement, airflow mixing, and complementary source control and ventilation strategies when deploying filtration-based IAQ interventions.Keywords
Funding Information
- HORIZON EUROPE Framework Programme (101057497)
- NextGenerationEU (533-03-23-0006)
This publication has 49 references indexed in Scilit:
- Evidence driven indoor air quality improvement: An innovative and interdisciplinary approach to improving indoor air qualityBioFactors, 2024
- Effect of portable air purifier on indoor air quality: reduced exposure to particulate matter and health risk assessmentEnvironmental Monitoring and Assessment, 2022
- Indoor air pollution of polycyclic aromatic hydrocarbons emitted by computersBuilding and Environment, 2022
- Use of portable air purifiers in homes: Operating behaviour, effect on indoor PM2.5 and perceived indoor air qualityBuilding and Environment, 2021
- Contributions of indoor and outdoor sources to airborne polycyclic aromatic hydrocarbons indoorsBuilding and Environment, 2018
- Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen U.S. citiesBuilding and Environment, 2016
- Indoor air quality requirements in green building certificationsBuilding and Environment, 2015
- Indoor PAHs at schools, homes and offices in Rome, ItalyAtmospheric Environment, 2014
- Characterization of particulate and vapor phase polycyclic aromatic hydrocarbons in indoor and outdoor air of primary schoolsAtmospheric Environment, 2014
- Polycyclic aromatic hydrocarbons (PAHs) in indoor emission from decorative candlesAtmospheric Environment, 2011