Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marija Jelena Lovrić Štefiček has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project

    by Nikolina Račić, Valentino Petrić, Gordana Pehnec, Ivana Jakovljević, Marija Jelena Lovrić Štefiček, Goran Gajski, Francesco Mureddu, Mario Lovrić

    This two-week pilot study within the Horizon Europe EDIAQI project evaluated the real-life performance of portable air filtration units in two office environments (a small office and a shared kitchen) under continuous device operation and daily filter replacement. Indoor particle concentrations were monitored continuously using low-cost sensors (LCS) from three providers and supported by gravimetric measurements, while daily activity logs documented occupancy patterns, printing, cooking, and other source events together with purifier ON/OFF status. Particulate matter (PM) mass concentrations showed no systematic improvement during purifier ON periods; instead, temporal variability was dominated by indoor activities and episodic emissions, with occasional short-term peaks around filter replacement suggestive of minor resuspension. Chemical analysis provided a clearer picture: polycyclic aromatic hydrocarbons (PAHs) responded differently across fractions and compositions. Across monitored locations, high-molecular-weight PAHs in the PM1 fraction decreased during purifier ON periods (approximately 30% lower on average), whereas low-molecular-weight PAHs measured in total suspended particles (TSP) were higher during ON periods, indicating that semi-volatile fractions and activity/ventilation dynamics can outweigh simple filtration effects. Overall, the findings highlight a gap between laboratory-derived filtration performance metrics and outcomes in occupied, mixed-source indoor environments and emphasise the importance of device sizing, placement, airflow mixing, and complementary source control and ventilation strategies when deploying filtration-based IAQ interventions.

  • Open Access

    Characterizing PM1-bound PAHs and PBDEs in urban households: Levels, sources, and health risks

    by Ivana Jakovljević, Marija Dvoršćak, Tajana Horvat, Darija Klinčić, Marija Jelena Lovrić Štefiček, Karla Jagić Nemčić, Gordana Pehnec, Mario Lovrić, Goran Gajski


  • Open Access

    Comparative Evaluation of Machine Learning Models for Residential PM1 Prediction in Zagreb (Croatia): Identifying Key Predictors and Indoor/Outdoor Dynamics

    by Marija Jelena Lovrić Štefiček, Silvije Davila, Gordana Pehnec, Ivan Bešlić, Željka Ujević Andrijić, Ivana Banić, Mirjana Turkalj, Mario Lovrić, Luka Kazensky, Goran Gajski

    Indoor exposure to particulate matter (PM) is increasingly recognized as a major contributor to respiratory and cardiovascular risk, yet the relative contributions of outdoor pollution, building characteristics, and occupant behavior remain poorly resolved. PM1 (aerodynamic diameter < 1 μm) warrants focus due to its higher alveolar deposition. “Evidence driven indoor air quality improvement” (EDIAQI) project aims to enhance indoor air quality guidelines and increase awareness by providing accessible data on exposure, pollution sources, and related risk factors. As part of the Zagreb pilot within the project, 103 paired indoor/outdoor PM1 samples were analyzed. Seasonal analysis revealed substantial wintertime outdoor PM1 spikes, while indoor medians remained stable. Chemometric analysis identified factors such as dwelling size, outdoor pollution, resuspension, building age/heating type, and urban context. Among the tested models, the validated gradient-boosted regressor (GBR) achieved the strongest performance, explaining ~65% variance in indoor PM1 (test R2 ≈ 0.65). Explainable machine learning analysis (SHAP) identified outdoor PM1 levels, infiltration, and resuspension as the most influential predictors. Findings underscore wintertime outdoor emissions (e.g., residential heating and traffic) and dwelling-related and behavioral factors as key drivers, with the machine learning–environmental data integration enabling targeted residential IAQ management: optimized ventilation protocols, resuspension mitigation via behavior, and infiltration reduction through retrofits.

  • Open Access

    Cytogenotoxic effects of polycyclic aromatic hydrocarbons complex mixture in human peripheral blood, lung A549 and liver HepG2 cells: Translation of a real-scenario exposure to in vitro

    by Luka Kazensky, Marija Jelena Lovrić Štefiček, Vilena Kašuba, Matjaž Novak, Karolina Belingar, Katarina Matković, Marko Gerić, Jasmina Rinkovec, Ivana Jakovljević, Katarina Baralić, et al.


  • Open Access

    Evaluation of Residential Indoor Radon Levels in Zagreb Using Machine Learning

    by Tomislav Bituh, Marija Jelena Lovrić Štefiček, Tea Čvorišćec, Branko Petrinec, Silvije Davila

    Machine learning (ML) models can complement traditional measurement-based approaches by supporting large-scale screening, spatial analysis, and prioritization of buildings for testing of indoor radon, a leading cause of lung cancer among non-smokers. Originating from uranium decay in soil and rock, radon enters homes via foundation cracks and accumulates indoors, influenced by building characteristics, ventilation, urbanization, and geogenic factors. As part of the Zagreb pilot within the “Evidence Driven Indoor Air Quality Improvement” (EDIAQI) project, this is the first ML application for indoor radon analysis in Croatia. This research evaluates residential indoor radon concentrations in Zagreb using ML applied to a dataset of 80 households. Several linear regression and tree-based ensemble methods were tested. The best-performing model (GBR) achieved an R2 of 0.99 on the training set and 0.57 on the test set, with an RMSE of 33 Bq/m3 and MAE of 26 Bq/m3. Although predictive performance was moderate and generalization limited, key building characteristics such as construction year, dwelling type, occupancy details, and floor level were identified as relevant variables. The results suggest that machine learning may support radon risk prioritization in urban environments, but cannot replace direct measurements for regulatory purposes.

  • Open Access

    Polybrominated Diphenyl Ethers (PBDEs) in PM1 of Residential Indoor Air: Levels, Seasonal Variability, and Inhalation Exposure Assessment

    by Darija Klinčić, Karla Jagić Nemčić, Ivana Jakovljević, Marija Jelena Lovrić Štefiček, Marija Dvoršćak

    Indoor exposure to polybrominated diphenyl ethers (PBDEs), particularly those bound to fine particulate matter (PM1, particles < 1 µm), may pose a health concern, especially in light of prolonged indoor occupancy and the capacity of ultrafine particles to reach the lower respiratory tract. This study investigates indoor exposure to PBDEs associated with PM1 in residential homes in Zagreb, Croatia, across warm and cold seasons. BDE-47 was consistently detected in all samples, while BDE-183 was consistently absent. Elevated concentrations and increased detection frequencies of BDE-99 and BDE-100 were observed during the colder season. Consequently, total PBDE (ΣPBDE) levels in the cold season were approximately 2.5 times higher than in the warm season. Although estimated daily inhalation intakes were below established oral reference doses, the potential for deep pulmonary deposition and systemic distribution underscores the need for further investigation. These findings represent the first reported data on indoor PM1-associated PBDEs in Europe, emphasizing the impact of seasonal dynamics on inhalation exposure due to variation on indoor contaminant levels.


  • Open Access

    Comparison of Sensors for Air Quality Monitoring with Reference Methods in Zagreb, Croatia

    by Silvije Davila, Marija Jelena Lovrić Štefiček, Ivan Bešlić, Gordana Pehnec, Marko Marić, Ivana Hrga

    Within the scope of “Eco Map of Zagreb” project, eight sensor sets (type AQMeshPod) were set up at an automatic measuring station at the Institute for Medical Research and Occupational Health (IMROH) for comparison with reference methods for air quality measurement during 2018. This station is a city background station within the Zagreb network for air quality monitoring, where measurements of SO2, CO, NO2, O3, PM10 and PM2.5, are performed using standardized methods accredited according to EN ISO/IEC 17025. This paper presents a comparison of pollutant mass concentrations determined by sensors with reference methods. The data were compared and filtered to remove outliers and handle deviations between the results obtained by sensors and reference methods, considering the different approaches to gas and PM data. A comparison of sensor results with the reference methods showed a large scattering of all gaseous pollutants while the comparison for PM10 and PM2.5 indicated a satisfactory low dispersion. The results of a regression analysis showed a significant seasonal dependence for all pollutants. Significant statistical differences between the reference methods and sensors for the whole year and in all seasons for all gas pollutants, as well as for PM10, were observed, while for PM2.5 statistical significance showed varying results.


  • Open Access

    Indoor Polycyclic Aromatic Hydrocarbons—Relationship to Ambient Air, Risk Estimation, and Source Apportionment Based on Household Measurements

    by Mario Lovrić, Nikolina Račić, Gordana Pehnec, Tajana Horvat, Marija Jelena Lovrić Štefiček, Ivana Jakovljević

    Polycyclic aromatic hydrocarbons (PAH) are key components of particulate matter (PM) in terms of the toxicological risk of polluted air. Although commonly monitored in ambient air, PAHs are also present in indoor air, making the measurement of indoor PAH content essential for understanding the health risks associated with indoor environments. This study presents findings from measurements conducted across 37 households where children resided, using 7-day sampling campaigns to collect PM1. The health risk assessment methods are detailed herein, along with a source apportionment analysis to explore the associations with potential sources and differences from ambient air concentrations. Additionally, the incremental lifetime cancer risk (ILCR) was calculated to assess long-term health risks associated with exposure to indoor PAHs. The results showed consistently higher PAH concentrations in outdoor environments (from 0.079 ng m−3 for dibenzo(a,h)anthracene to 1.638 ng m−3 for benzo(b)fluoranthene) compared to indoor environments (from 0.029 ng m−3 for dibenzo(a,h)anthracene to 0.772 ng m−3 for indeno(1,2,3-cd)pyrene), suggesting significant transfer of PAHs from outdoor to indoor air. The source apportionment analysis indicated that traffic emissions, fossil fuel combustion, and residential heating were the predominant sources of PAHs in both environments, with the concentration of indoor PAHs largely influenced by gasoline and liquid fossil fuel combustion. The diagnostic ratios supported these findings, with coal and biomass as additional sources impacting outdoor PAH levels. The ILCR analysis revealed that the exposure levels for both children (indoors at 1.78 × 10−5, outdoors at 1.92 × 10−6) and adults (indoors at 1.15 × 10−5, outdoors at 1.24 × 10−6) remained below the U.S. EPA’s risk threshold, suggesting limited carcinogenic risk under typical household conditions in this study. These findings emphasize the complexity of PAH distribution between indoor and outdoor environments, illustrating how urban outdoor pollution sources contribute to indoor air quality and highlighting the relevance of effective air quality management strategies.


  • Open Access

    Resveratrol–Maltol and Resveratrol–Thiophene Hybrids as Cholinesterase Inhibitors and Antioxidants: Synthesis, Biometal Chelating Capability and Crystal Structure

    by Milena Mlakić, Lajos Fodor, Ilijana Odak, Ottó Horváth, Marija Jelena Lovrić, Danijela Barić, Valentina Milašinović, Krešimir Molčanov, Željko Marinić, Zlata Lasić, et al.

    New resveratrol–thiophene and resveratrol–maltol hybrids were synthesized as cholinesterase inhibitors and antioxidants. As with photostability experiments, biological tests also found remarkable differences in the properties and behavior of thiophene and maltol hybrids. While resveratrol–thiophene hybrids have excellent inhibitory and antioxidant properties (similar to the activity of reference drug galantamine), maltols have been proven to be weaker inhibitors and antioxidants. The molecular docking of selected active ligands gave insight into the structures of docked enzymes. It enabled the identification of interactions between the ligand and the active site of both cholinesterases. The maltols that proved to be active cholinesterase inhibitors were able to coordinate Fe3+ ion, forming complexes of 1:1 composition. Their formation constants, determined by spectrophotometry, are very similar, lgK = 11.6–12.6, suggesting that Fe3+ binds to the common hydroxy-pyranone moiety and is hardly affected by the other aromatic part of the ligand. Accordingly, the characteristic bands in their individual absorption spectra are uniformly red-shifted relative to those of the free ligands. The crystal structures of two new resveratrol–maltol hybrids were recorded, giving additional information on the molecules’ intermolecular hydrogen bonds and packing. In this way, several functionalities of these new resveratrol hybrids were examined as a necessary approach to finding more effective drugs for complicated neurodegenerative diseases.