It is known that 12C beam transmission through the accelerator decreases at high beam currents. This effect depends on machine design and varies across different types of AMS instruments. For beam currents of about 100 μA, the effect is small on the 500 kV tandem CAMS unit, whereas beam saturation is observed for similar high beam currents on the 250 kV SSAMS unit. While this effect is very evident for high 12C beam currents, we have also observed that even the 13C beam is found to suffer modest transmission loss with beam current. As a result, the 13C/12C ratio does not remain constant with beam current. By correcting for the effects of 12C beam saturation and decreased 13C transmission, we have obtained online δ13C values that are more accurate and precise at moderately high beam currents for SSAMS.Keywords
This publication has 11 references indexed in Scilit:
- Status report of the 1 MV AMS facility at the Centro Nacional de AceleradoresNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- Two years since SSAMS: Status of 14C AMS at CAISNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- Radiocarbon measurements at LAC-UFF: Recent performanceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- AixMICADAS, the accelerator mass spectrometer dedicated to 14C recently installed in Aix-en-Provence, FranceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- The New 250kV Single Stage AMS System at CAIS, University of Georgia: Performance Comparison with a 500kV Compact Tandem MachineRadiocarbon, 2013
- Status of the Single Stage AMS machine at Lund University after 4 years of operationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Improved SSAMS performanceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Performance of the new single stage accelerator mass spectrometer at the SUERCNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2008
- The single stage AMS machine at Lund University: Status reportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2007
- MICADAS: A new compact radiocarbon AMS systemNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2007