One-year follow-up of conduction disturbances following transcatheter aortic valve implantation
Authors:
- Stefano SalizzoniStefano Salizzoni
- Matteo AnselminoMatteo Anselmino
- Cristina FornengoCFCristina Fornengo
- Francesca GiordanaFGFrancesca Giordana
- Michele La TorreMTMichele La Torre
- Claudio MorettiCMClaudio Moretti
- Maurizio D’amicoMDMaurizio D’amico
- Pierluigi OmedéPOPierluigi Omedé
- Sebastiano MarraSMSebastiano Marra
- Mauro RinaldiMRMauro Rinaldi
- Fiorenzo GaitaFGFiorenzo Gaita
- 1 April 2015
- journal article
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 16 (4) , 296-302
Abstract
To describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). Ninety-five patients were enrolled from 2008 to 2011 (mean age 81.8 ± 7.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI. Fifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P = 0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 ± 29 vs. 188 ± 36 ms; P = 0.001), QRS width (90 ± 15 vs. 108 ± 26 ms; P < 0.001), and first-grade atrioventricular block (17 vs. 29%; P < 0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P = 0.01) and CoreValve (from 8 to 64%; P < 0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 ± 27 vs. 188 ± 36 ms; P = 0.39) remained unchanged in the ECG, whereas the QRS width (100 ± 22 vs. 108 ± 26 ms; P = 0.008) decreased compared to measurements taken at discharge. Conduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.Keywords
This publication has 22 references indexed in Scilit:
- Predictive Factors and Long-Term Clinical Consequences of Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Implantation With a Balloon-Expandable ValveJACC, 2012
- Surface and intracardiac ECG for discriminating conduction disorders after CoreValve implantationClinical Research in Cardiology, 2011
- Predictors and Course of High-Degree Atrioventricular Block After Transcatheter Aortic Valve Implantation Using the CoreValve Revalving systemThe American Journal of Cardiology, 2011
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsThe New England journal of medicine, 2011
- Atrioventricular Conduction Disturbance Characterization in Transcatheter Aortic Valve Implantation With the CoreValve ProsthesisCirculation: Cardiovascular Interventions, 2011
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryThe New England journal of medicine, 2010
- Electrocardiographic changes and clinical outcomes after transapical aortic valve implantationAmerican Heart Journal, 2009
- Early Conduction Disorders Following Percutaneous Aortic Valve ReplacementPacing and Clinical Electrophysiology, 2009
- Early and Persistent Intraventricular Conduction Abnormalities and Requirements for Pacemaking After Percutaneous Replacement of the Aortic ValveJACC: Cardiovascular Interventions, 2008
- Atrioventricular Block After Transcatheter Balloon Expandable Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2008