Extra-Aneurysmal Flow Modification Following Pipeline Embolization Device Implantation: Focus on Regional Branches, Perforators, and the Parent Vessel
Open Access
- 18 December 2014
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (4) , 725-731
Abstract
BACKGROUND AND PURPOSE: Flow-diverter technology has proved to be a safe and effective treatment for intracranial aneurysm based on the concept of flow diversion allowing parent artery and collateral preservation and aneurysm healing. We investigated the patency of covered side branches and flow modification within the parent artery following placement of the Pipeline Embolization Device in the treatment of intracranial aneurysms. MATERIALS AND METHODS: Sixty-six aneurysms in 59 patients were treated with 96 Pipeline Embolization Devices. We retrospectively reviewed imaging and clinical results during the postoperative period at 6 and 12 months to assess flow modification through the parent artery and side branches. Reperfusion syndrome was assessed by MR imaging and clinical evaluation. RESULTS: Slow flow was observed in 13 of 68 (19.1%) side branches covered by the Pipeline Embolization Device. It was reported in all cases of anterior cerebral artery coverage, in 3/5 cases of M2-MCA coverage, and in 5/34 (14.7%) cases of ophthalmic artery coverage. One territorial infarction was observed in a case of M2-MCA coverage, without arterial occlusion. One case of deep Sylvian infarct was reported in a case of coverage of MCA perforators. Two ophthalmic arteries (5.9%) were occluded, and 11 side branches (16.2%) were narrowed at 12 months' follow-up; patients remained asymptomatic. Parent vessel flow modification was responsible for 2 cases (3.4%) of reperfusion syndrome. Overall permanent morbidity and mortality rates were 5.2% and 6.9%, respectively. We did not report any permanent deficit or death in case of slow flow observed within side branches. CONCLUSIONS: After Pipeline Embolization Device placement, reperfusion syndrome was observed in 3.4%, and territorial infarction, in 3.4%. Delayed occlusion of ophthalmic arteries and delayed narrowing of arteries covered by the Pipeline Embolization Device were observed in 5.9% and 16.2%, respectively. No permanent morbidity or death was related to side branch coverage at midterm follow-up.Keywords
This publication has 43 references indexed in Scilit:
- Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular AneurysmsStroke, 2013
- The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow divertersAsian Journal of Neurosurgery, 2012
- Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation AneurysmsAmerican Journal of Neuroradiology, 2012
- Cerebral Hyperperfusion Syndrome After Carotid InterventionCardiology in Review, 2012
- Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single CenterAmerican Journal of Neuroradiology, 2011
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- Flow Diversion for Intracranial AneurysmsStroke, 2011
- MRI evidence of reperfusion injury associated with neurological deficits after carotid revascularization proceduresEuropean Journal of Neurology, 2009
- Postcarotid Endarterectomy Hyperperfusion or Reperfusion SyndromeStroke, 2005