Vibration Property of a Cryogenic Optical Resonator within a Pulse-Tube Cryostat
Open Access
Abstract
Cryogenic ultrastable laser cavities push laser stability to new levels due to their lower thermal noise limitation. Vibrational noise is one of the major obstacles to achieve a thermal-noise-limited cryogenic ultrastable laser system. Here, we carefully analyze the vibrational noise contribution to the laser frequency. We measure the vibrational noise from the top of the pulse-tube cryocooler down to the experiment space. Major differences emerge between room and cryogenic temperature operation. We cooled a homemade 6 cm sapphire optical resonator down to 3.4 K. Locking a 1064 nm laser to the resonator, we measure a frequency stability of . The vibration sensitivities change at different excitation frequencies. The vibrational noise analysis of the laser system paves the way for in situ accurate evaluation of vibrational noise for cryogenic systems. This may help in cryostat design and cryogenic precision measurements.
Keywords
Funding Information
- National Key Research and Development Program of China (2017YFA0304400)
- Key-Area Research of GuangDong Province (2019B030330001)
- National Natural Science Foundation of China (61875065, 11774108, 91336213)
- China Postdoctoral Science Foundation (2017M622400)
This publication has 26 references indexed in Scilit:
- Transportable cavity-stabilized laser system for optical carrier frequency transmission experimentsApplied Optics, 2014
- High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostatReview of Scientific Instruments, 2014
- A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavityNature Photonics, 2012
- Detector configuration of KAGRA–the Japanese cryogenic gravitational-wave detectorClassical and Quantum Gravity, 2012
- Cryogenic sapphire oscillator using a low- vibration design pulse-tube cryocooler: first resultsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2010
- A vibration free cryostat using pulse tube cryocoolerCryogenics, 2010
- Inelastic electron tunneling spectroscopy with a dilution refrigerator based scanning tunneling microscopeMeasurement Science and Technology, 2009
- Vibration-free cryostat for low-noise applications of a pulse tube cryocoolerReview of Scientific Instruments, 2006
- Tests of Relativity Using a Cryogenic Optical ResonatorPhysical Review Letters, 2001
- Low-phase noise temperature-compensated cryogenic whispering gallery mode resonator operated at 63 K in a closed-cycle coolerIEEE Transactions on Instrumentation and Measurement, 2001