Yanxia Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanxia Ye has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jie Zhang
Huazhong University of Science and Technology
5 shared publications - Yunlong Sun
College of Light Industry and Textile, Inner Mongolia University of Technology, Hohhot, China
3 shared publications Chun-Jie Yan
Physics, Huazhong University of Science and Technology, Wuhan, China
2 shared publicationsFenglei Zhang
2 shared publicationsLei-Lei He
Huazhong University of Science and Technology, Wuhan, China
2 shared publicationsLeilei He
2 shared publications
Latest Publications
- 27 August 2021
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 38 (19) , 195005
Investigation on the thermal property of a hydroxide catalysis bonded cryogenic cavity
Cryogenic ultra-stable Fabry–Perot cavity is one of the most promising reference cavities for laser stabilization. Here we investigate the thermal property of a hydroxide catalysis bonded silicon–sapphire hybrid cavity for 1064 nm laser stabilization. The zero-thermal expansion temperature is measured to be 15.0 ± 0.1 K, with a slope calculated to be 3 × 10 −10 K −2 . A simulation model with a few micrometer thick silicon oxidation layer reproduces well the experimental results. The investigations on the thermal property of the hydroxide catalysis bonded components are important for the noise evaluation and optimization. This work would be valuable for the advanced cryogenic optics, and would be interested for researchers working on cryogenic ultra-stable lasers and cryogenic gravitational wave detectors.
- 27 August 2021
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 38 (19) , 195005
Investigation on the thermal property of a hydroxide catalysis bonded cryogenic cavity
Cryogenic ultra-stable Fabry–Perot cavity is one of the most promising reference cavities for laser stabilization. Here we investigate the thermal property of a hydroxide catalysis bonded silicon–sapphire hybrid cavity for 1064 nm laser stabilization. The zero-thermal expansion temperature is measured to be 15.0 ± 0.1 K, with a slope calculated to be 3 × 10 −10 K −2 . A simulation model with a few micrometer thick silicon oxidation layer reproduces well the experimental results. The investigations on the thermal property of the hydroxide catalysis bonded components are important for the noise evaluation and optimization. This work would be valuable for the advanced cryogenic optics, and would be interested for researchers working on cryogenic ultra-stable lasers and cryogenic gravitational wave detectors.
- Open Access
Vibration Property of a Cryogenic Optical Resonator within a Pulse-Tube Cryostat
Cryogenic ultrastable laser cavities push laser stability to new levels due to their lower thermal noise limitation. Vibrational noise is one of the major obstacles to achieve a thermal-noise-limited cryogenic ultrastable laser system. Here, we carefully analyze the vibrational noise contribution to the laser frequency. We measure the vibrational noise from the top of the pulse-tube cryocooler down to the experiment space. Major differences emerge between room and cryogenic temperature operation. We cooled a homemade 6 cm sapphire optical resonator down to 3.4 K. Locking a 1064 nm laser to the resonator, we measure a frequency stability of . The vibration sensitivities change at different excitation frequencies. The vibrational noise analysis of the laser system paves the way for in situ accurate evaluation of vibrational noise for cryogenic systems. This may help in cryostat design and cryogenic precision measurements.Open AccessVibration Property of a Cryogenic Optical Resonator within a Pulse-Tube Cryostat
Cryogenic ultrastable laser cavities push laser stability to new levels due to their lower thermal noise limitation. Vibrational noise is one of the major obstacles to achieve a thermal-noise-limited cryogenic ultrastable laser system. Here, we carefully analyze the vibrational noise contribution to the laser frequency. We measure the vibrational noise from the top of the pulse-tube cryocooler down to the experiment space. Major differences emerge between room and cryogenic temperature operation. We cooled a homemade 6 cm sapphire optical resonator down to 3.4 K. Locking a 1064 nm laser to the resonator, we measure a frequency stability of . The vibration sensitivities change at different excitation frequencies. The vibrational noise analysis of the laser system paves the way for in situ accurate evaluation of vibrational noise for cryogenic systems. This may help in cryostat design and cryogenic precision measurements. - 7 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (21) , 215008
3 m × 3 m heterolithic passive resonant gyroscope with cavity length stabilization
Large-scale high sensitivity laser gyroscopes have important applications for ground-based and space-based gravitational wave detection. We report on the development of a 3 m × 3 m heterolithic passive resonant gyroscope (HUST-1) which is installed on the ground of a cave laboratory. We operate the HUST-1 on different longitudinal cavity modes and the rotation sensitivity reaches 1.6 × 10 −9 rad s −1 Hz −1/2 above 1 Hz. The drift of the cavity length is one of the major sensitivity limits for our gyroscope in the low frequency regime. By locking cavity length to an ultra-stable reference laser, we achieve a cavity length stability of 5.6 × 10 −9 m Hz −1/2 at 0.1 mHz, a four orders of magnitude improvement over the unconstrained cavity in the low frequency regime. We stabilize the cavity length of a large-scale heterolithic passive resonant gyroscope through active feedback and realize long-term operation. The rotation sensitivity reaches 1.7 × 10 −7 rad s −1 Hz −1/2 at 0.1 mHz, a three orders of magnitude improvement over the unconstrained cavity, which is no longer limited by the cavity length drift in this frequency range.
- 7 October 2020
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (21) , 215008
3 m × 3 m heterolithic passive resonant gyroscope with cavity length stabilization
Large-scale high sensitivity laser gyroscopes have important applications for ground-based and space-based gravitational wave detection. We report on the development of a 3 m × 3 m heterolithic passive resonant gyroscope (HUST-1) which is installed on the ground of a cave laboratory. We operate the HUST-1 on different longitudinal cavity modes and the rotation sensitivity reaches 1.6 × 10 −9 rad s −1 Hz −1/2 above 1 Hz. The drift of the cavity length is one of the major sensitivity limits for our gyroscope in the low frequency regime. By locking cavity length to an ultra-stable reference laser, we achieve a cavity length stability of 5.6 × 10 −9 m Hz −1/2 at 0.1 mHz, a four orders of magnitude improvement over the unconstrained cavity in the low frequency regime. We stabilize the cavity length of a large-scale heterolithic passive resonant gyroscope through active feedback and realize long-term operation. The rotation sensitivity reaches 1.7 × 10 −7 rad s −1 Hz −1/2 at 0.1 mHz, a three orders of magnitude improvement over the unconstrained cavity, which is no longer limited by the cavity length drift in this frequency range.
- 11 April 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (10) , 105007
A hybrid silicon-sapphire cryogenic Fabry–Perot cavity using hydroxide catalysis bonding
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if the flatness and the thermally grown SiO_2 oxidation layer on the silicon surface are controlled well, the bonded samples can still survive thermal cycling from room temperature to 5.5 K. A breaking strength of 3.6±0.6 MPa is measured for the bonds between sapphire and silicon with a 190 nm silicon oxidation thickness after cooling cycle. We construct a hybrid sapphire-silicon Fabry-Perot cavity with the developing bonding technique in our lab. The measurement results reveal that the cavity can survive repeated thermal cycling while maintaining a good finesse.
- 11 April 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (10) , 105007
A hybrid silicon-sapphire cryogenic Fabry–Perot cavity using hydroxide catalysis bonding
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if the flatness and the thermally grown SiO_2 oxidation layer on the silicon surface are controlled well, the bonded samples can still survive thermal cycling from room temperature to 5.5 K. A breaking strength of 3.6±0.6 MPa is measured for the bonds between sapphire and silicon with a 190 nm silicon oxidation thickness after cooling cycle. We construct a hybrid sapphire-silicon Fabry-Perot cavity with the developing bonding technique in our lab. The measurement results reveal that the cavity can survive repeated thermal cycling while maintaining a good finesse.
- Open Access
A hybrid silicon-sapphire cryogenic Fabry-Perot cavity using hydroxide catalysis bonding
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if the flatness and the thermally grown $\mathrm{SiO_2}$ oxidation layer on the silicon surface are controlled well, the bonded samples can still survive thermal cycling from room temperature to 5.5 K. A breaking strength of 3.6$\pm 0.6$ MPa is measured for the bonds between sapphire and silicon with a 190 nm silicon oxidation thickness after cooling cycle. We construct a hybrid sapphire-silicon Fabry-Perot cavity with the developing bonding technique in our lab. The measurement results reveal that the cavity can survive repeated thermal cycling while maintaining a good finesse.Open AccessA hybrid silicon-sapphire cryogenic Fabry-Perot cavity using hydroxide catalysis bonding
The third-generation gravitational wave detectors are under development by operating the detector in cryogenic temperature to reduce the thermal noise. Silicon and sapphire are promising candidate materials for the test masses and suspension elements due to their remarkable mechanical and thermal properties at cryogenic temperature. Here we present the performances of the cryogenic thermal cycling and strength testing on hydroxide catalysis bonding between sapphire and silicon. Our results suggest that although these two materials have very different coefficients of thermal expansion, but if the flatness and the thermally grown $\mathrm{SiO_2}$ oxidation layer on the silicon surface are controlled well, the bonded samples can still survive thermal cycling from room temperature to 5.5 K. A breaking strength of 3.6$\pm 0.6$ MPa is measured for the bonds between sapphire and silicon with a 190 nm silicon oxidation thickness after cooling cycle. We construct a hybrid sapphire-silicon Fabry-Perot cavity with the developing bonding technique in our lab. The measurement results reveal that the cavity can survive repeated thermal cycling while maintaining a good finesse.