Highly k‐t‐space–accelerated phase‐contrast MRI
Authors:
Open Access
- 27 October 2008
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (5) , 1169-1177
Abstract
The purpose of this study was to combine a recently introduced spatiotemporal parallel imaging technique, PEAK‐GRAPPA (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition), with two‐dimensional (2D) cine phase‐contrast velocity mapping. Phase‐contrast MRI was applied to measure the blood flow in the thoracic aorta and the myocardial motion of the left ventricle. To evaluate the performance of different reconstruction methods, fully acquired k‐space data sets were used to compare conventional parallel imaging using GRAPPA with reduction factors of R = 2–6 and PEAK‐GRAPPA as well as sliding window reconstruction with reduction factors R = 2–12 (net acceleration factors up to 5.2). PEAK‐GRAPPA reconstruction resulted in improved image quality with considerably reduced artifacts, which was also supported by error analysis. To analyze potential blurring or low‐pass filtering effects of spatiotemporal PEAK‐GRAPPA, the velocity time courses of aortic flow and myocardial tissue motion were evaluated and compared with conventional image reconstructions. Quantitative comparisons of blood flow velocities and pixel‐wise correlation analysis of velocities highlight the potential of PEAK‐GRAPPA for highly accelerated dynamic phase‐contrast velocity mapping. Magn Reson Med 60:1169–1177, 2008.Keywords
This publication has 16 references indexed in Scilit:
- Detailed analysis of myocardial motion in volunteers and patients using high‐temporal‐resolution MR tissue phase mappingJournal of Magnetic Resonance Imaging, 2006
- Accelerating cine phase‐contrast flow measurements using k‐t BLAST and k‐t SENSEMagnetic Resonance in Medicine, 2005
- Optimizing spatiotemporal sampling for k‐t BLAST and k‐t SENSE: Application to high‐resolution real‐time cardiac steady‐state free precessionMagnetic Resonance in Medicine, 2005
- Time-Resolved 3-Dimensional Velocity Mapping in the Thoracic AortaJournal of Computer Assisted Tomography, 2004
- Accuracy and reproducibility in phase contrast imaging using SENSEMagnetic Resonance in Medicine, 2003
- Time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Magnetic resonance measurement of velocity and flow: Technique, validation, and cardiovascular applicationsAmerican Heart Journal, 1993
- Magnetic resonance velocity mapping: clinical application of a new technique.Heart, 1987