In vitro quality and hemostatic function of cold‐stored CPDA‐1 whole blood after repeated transient exposure to 28°C storage temperature
Open Access
- 24 June 2022
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 62 (S1) , S105-S113
Abstract
Background: Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA‐1 whole blood.Study Design and Methods: 450 ml of whole blood from 16 O Rh(D) positive donors was collected in 63 ml of CPDA‐1 and stored cold. Eights bags were exposed to five weekly 4‐h long transient temperature changes to 28°C. Eight bags were stored continuously at 4°C as a control. Samples were collected at baseline on day 1, after the first cycle on day 1 and weekly before each subsequent cycle (day 7, 14, 21, 28 and 35). Hemolysis, hematological parameters, pH, glucose, lactate, potassium, thromboelastography, INR, APTT, fibrinogen, and factor VIII were measured.Results: CPDA‐1 whole blood repeatedly exposed to 28°C did not show reduced quality compared to the control group on day 35. Two units in the test group had hemolysis of 1.1% and 1.2%, and two in the control group hemolysis of 0.8%. Remaining thromboelastography clot strength (MA) on day 35 was 51.7 mm (44.8, 58.6) in the test group and 46.1 (41.6, 50.6) in the control group (p = .023). Platelet count was better preserved in the test group (166.7 [137.8, 195.6] vs. 117.8 [90.3, 145.2], p = .018). One sample in the test group was positive for Cutibacterium acnes on day 35 + 6.Conclusion: Hemolysis findings warrant further investigation. Other indicators of quality were not negatively affected.Keywords
This publication has 25 references indexed in Scilit:
- Bacterial growth in red blood cell units exposed to uncontrolled temperatures: challenging the 30‐minute ruleVox Sanguinis, 2013
- Primary hemostatic capacity of whole blood: a comprehensive analysis of pathogen reduction and refrigeration effects over timeTransfusion, 2013
- What Is the Maximum Time That a Unit of Red Blood Cells Can Be Safely Left Out of Controlled Temperature Storage?Transfusion Medicine Reviews, 2012
- Repeated short‐term warming of red blood cell concentrates has minimal effect on their qualityVox Sanguinis, 2012
- Toward a definition of “fresh” whole blood: an in vitro characterization of coagulation properties in refrigerated whole blood for transfusionTransfusion, 2011
- Core and surface temperatures in a red-blood-cell unit during storage and transportVox Sanguinis, 2010
- The use of the mechanical fragility test in evaluating sublethal RBC injury during storageVox Sanguinis, 2010
- Effect of EDTA on Platelet Count and Other Platelet Parameters in Blood and Blood Components Collected with CPDA‐1Vox Sanguinis, 1991
- Temperature Changes in Donor Blood under Different Storage ConditionsTransfusion, 1971
- SKIN FRAGMENTS REMOVED BY INJECTION NEEDLESThe Lancet, 1958