A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
Open Access
Abstract
A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise from scattering and electrical noise without using complex and bulky circuits. In addition, an asynchronous fastest signal identifier and a self-trimmed comparator are proposed to identify the fastest signal without using a high-frequency clock and to reduce misidentification, respectively. The channel reduction ratio of the proposed ROIC is 16:1 and can be extended to 16 × N:1 using N ROICs. To verify the performance of the two-step FSI, the proposed ROIC was implemented into a gamma photon detector module using a Geiger-mode avalanche photodiode with a lutetium-yttrium oxyorthosilicate array. The measured minimum detectable time is 1 ns. The difference of the measured energy and timing resolution between with and without the two-step FSI are 0.8% and 0.2 ns, respectively, which are negligibly small. These measurement results show that the proposed ROIC using the two-step FSI reduces the number of input channels of the DAQ block without sacrificing the performance of the positron emission tomography (PET) systems.Keywords
This publication has 17 references indexed in Scilit:
- Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CTSensors, 2015
- CMOS Flat-Panel X-ray Detector With Dual-Gain Active Pixel Sensors and Column-Parallel Readout CircuitsIEEE Transactions on Nuclear Science, 2014
- Development of a PET Scanner for Simultaneously Imaging Small Animals with MRI and PETSensors, 2014
- Development of a high-density position decoder circuit for GAPD-based PET with a large number of readout channelsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Three-Side Buttable Integrated Ultrasound Chip With a 16$\,\times\,$16 Reconfigurable Transceiver and Capacitive Micromachined Ultrasonic Transducer Array for 3-D Ultrasound Imaging SystemsIEEE Transactions on Electron Devices, 2013
- A Support-Based Reconstruction for SENSE MRISensors, 2013
- Ultrasound beamformer using pipeline-operated S/H delay stages and charge-mode summationElectronics Letters, 2011
- A Single-Temperature Trimming Technique for MOS-Input Operational Amplifiers Achieving 0.33 $\mu$V/$^{\circ}$C Offset DriftIEEE Journal of Solid-State Circuits, 2011
- Development of a position decoder circuit for PET consisting of GAPD arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilizationProceedings of the IEEE, 1996