Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
- 31 January 2013
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 1169-1184
Abstract
In proton beam therapy, changes in the proton range due to lateral heterogeneity may cause serious errors in the dose distribution. In the present study, the pencil-beam redefinition algorithm (PBRA) was applied to proton beam therapy to address the problem of lateral density heterogeneity. In the calculation, the phase-space parameters were characterized for multiple range (i.e. proton energy) bins for given pencil beams. The particles that were included in each pencil beam were transported and redefined periodically until they had stopped. The redefined beams formed a detouring path that was different from that of the non-redefined pencil beams, and the path of each redefined beam was straight. The results calculated by the PBRA were compared with measured proton dose distributions in a heterogeneous slab phantom and an anthropomorphic phantom. Through the beam redefinition process, the PBRA was able to predict the measured proton-detouring effects. Therefore, the PBRA may allow improved calculation accuracy when dealing with lateral heterogeneities in proton therapy applications.Keywords
This publication has 22 references indexed in Scilit:
- Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapyMedical Physics, 2012
- GPU-based fast pencil beam algorithm for proton therapyPhysics in Medicine & Biology, 2011
- Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantomPhysics in Medicine & Biology, 2010
- Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matterPhysics in Medicine & Biology, 2009
- Influence of multiple scattering and energy loss straggling on the absorbed dose distributions of therapeutic light ion beams: I. Analytical pencil beam modelPhysics in Medicine & Biology, 2004
- Electron pencil‐beam redefinition algorithm dose calculations in the presence of heterogeneitiesMedical Physics, 2001
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996
- Multiple Coulomb scattering of 160 MeV protonsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1993
- Electron beam dose calculationsPhysics in Medicine & Biology, 1981
- Multiple Scattering with Energy LossPhysical Review B, 1948