Teiji Nishio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Teiji Nishio has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Hideki Takegawa
Kansai Medical University
2 shared publications - Kentaro Doi
AI Center for Health and Biomedical Research (ArCHER), National Institutes of Biomedical Innovation, Health and Nutrition, Osaka, 566-0002, Japan
2 shared publications - Mitsuru Uesaka
The University of Tokyo
2 shared publications - Yuhei Koike
Department of Radiology, Kansai Medical University , 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010
2 shared publications - Yusuke Anetai
Department of Radiology, Kansai Medical University, Osaka, Japan
2 shared publications Akihisa Wakita
Department of Radiation Oncology, National Cancer Center Hospital
1 shared publication
Latest Publications
- Open Access
- 5 October 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195028
Extracting the gradient component of the gamma index using the Lie derivative method
Objective . The gamma index ( γ ) has been extensively investigated in the medical physics and applied in clinical practice. However, γ has a significant limitation when used to evaluate the dose-gradient region, leading to inconveniences, particularly in stereotactic radiotherapy (SRT). This study proposes a novel evaluation method combined with γ to extract clinically problematic dose-gradient regions caused by irradiation including certain errors. Approach . A flow-vector field in the dose distribution is obtained when the dose is considered a scalar potential. Using the Lie derivative from differential geometry, we defined L , S , and U to evaluate the intensity, vorticity, and flow amount of deviation between two dose distributions, respectively. These metrics multiplied by γ ( γL , γS , γU ), along with the threshold value σ , were verified in the ideal SRT case and in a clinical case of irradiation near the brainstem region using radiochromic films. Moreover, Moran’s gradient index (MGI), Bakai’s χ factor, and the structural similarity index (SSIM) were investigated for comparisons. Main results . A high L- metric value mainly extracted high-dose-gradient induced deviations, which was supported by high S and U metrics observed as a robust deviation and an influence of the dose-gradient, respectively. The S- metric also denotes the measured similarity between the compared dose distributions. In the γ distribution, γL sensitively detected the dose-gradient region in the film measurement, despite the presence of noise. The threshold σ successfully extracted the gradient-error region where γ > 1 analysis underestimated, and σ = 0.1 (plan) and σ = 0.001 (film measurement) were obtained according to the compared resolutions. However, the MGI, χ, and SSIM failed to detect the clinically interested region. Significance . Although further studies are required to clarify the error details, this study demonstrated that the Lie derivative method provided a novel perspective for the identifying gradient-induced error regions and enabled enhanced and clinically significant evaluations of γ .
- 5 October 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195028
Open AccessExtracting the gradient component of the gamma index using the Lie derivative method
Objective . The gamma index ( γ ) has been extensively investigated in the medical physics and applied in clinical practice. However, γ has a significant limitation when used to evaluate the dose-gradient region, leading to inconveniences, particularly in stereotactic radiotherapy (SRT). This study proposes a novel evaluation method combined with γ to extract clinically problematic dose-gradient regions caused by irradiation including certain errors. Approach . A flow-vector field in the dose distribution is obtained when the dose is considered a scalar potential. Using the Lie derivative from differential geometry, we defined L , S , and U to evaluate the intensity, vorticity, and flow amount of deviation between two dose distributions, respectively. These metrics multiplied by γ ( γL , γS , γU ), along with the threshold value σ , were verified in the ideal SRT case and in a clinical case of irradiation near the brainstem region using radiochromic films. Moreover, Moran’s gradient index (MGI), Bakai’s χ factor, and the structural similarity index (SSIM) were investigated for comparisons. Main results . A high L- metric value mainly extracted high-dose-gradient induced deviations, which was supported by high S and U metrics observed as a robust deviation and an influence of the dose-gradient, respectively. The S- metric also denotes the measured similarity between the compared dose distributions. In the γ distribution, γL sensitively detected the dose-gradient region in the film measurement, despite the presence of noise. The threshold σ successfully extracted the gradient-error region where γ > 1 analysis underestimated, and σ = 0.1 (plan) and σ = 0.001 (film measurement) were obtained according to the compared resolutions. However, the MGI, χ, and SSIM failed to detect the clinically interested region. Significance . Although further studies are required to clarify the error details, this study demonstrated that the Lie derivative method provided a novel perspective for the identifying gradient-induced error regions and enabled enhanced and clinically significant evaluations of γ .
- 29 March 2023
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 41 (8) , 900-908
Deep learning-based detection of patients with bone metastasis from Japanese radiology reports
Purpose Deep learning (DL) is a state-of-the-art technique for developing artificial intelligence in various domains and it improves the performance of natural language processing (NLP). Therefore, we aimed to develop a DL-based NLP model that classifies the status of bone metastasis (BM) in radiology reports to detect patients with BM. Materials and Methods The DL-based NLP model was developed by training long short-term memory using 1,749 free-text radiology reports written in Japanese. We adopted five-fold cross-validation and used 200 reports for testing the five models. The accuracy, sensitivity, specificity, precision, and area under the receiver operating characteristics curve (AUROC) were used for the model evaluation. Results The developed model demonstrated classification performance with mean ± standard deviation of 0.912 ± 0.012, 0.924 ± 0.029, 0.901 ± 0.014, 0.898 ± 0.012, and 0.968 ± 0.004 for accuracy, sensitivity, specificity, precision, and AUROC, respectively. Conclusion The proposed DL-based NLP model may help in the early and efficient detection of patients with BM.
- 29 March 2023
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 41 (8) , 900-908
Deep learning-based detection of patients with bone metastasis from Japanese radiology reports
Purpose Deep learning (DL) is a state-of-the-art technique for developing artificial intelligence in various domains and it improves the performance of natural language processing (NLP). Therefore, we aimed to develop a DL-based NLP model that classifies the status of bone metastasis (BM) in radiology reports to detect patients with BM. Materials and Methods The DL-based NLP model was developed by training long short-term memory using 1,749 free-text radiology reports written in Japanese. We adopted five-fold cross-validation and used 200 reports for testing the five models. The accuracy, sensitivity, specificity, precision, and area under the receiver operating characteristics curve (AUROC) were used for the model evaluation. Results The developed model demonstrated classification performance with mean ± standard deviation of 0.912 ± 0.012, 0.924 ± 0.029, 0.901 ± 0.014, 0.898 ± 0.012, and 0.968 ± 0.004 for accuracy, sensitivity, specificity, precision, and AUROC, respectively. Conclusion The proposed DL-based NLP model may help in the early and efficient detection of patients with BM.
- Open Access
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 84-91
Feasibility of image quality improvement for high-speed CBCT imaging using deep convolutional neural network for image-guided radiotherapy in prostate cancer
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 84-91
Open AccessFeasibility of image quality improvement for high-speed CBCT imaging using deep convolutional neural network for image-guided radiotherapy in prostate cancer
- Open Access
- 1 January 2017
- Published by Japan Academy in Proceedings of the Japan Academy, Series B
- Vol. 93 (10) , 821-831
Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 1 January 2017
- Published by Japan Academy in Proceedings of the Japan Academy, Series B
- Vol. 93 (10) , 821-831
Open AccessEvaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 31 January 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 1169-1184
Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
In proton beam therapy, changes in the proton range due to lateral heterogeneity may cause serious errors in the dose distribution. In the present study, the pencil-beam redefinition algorithm (PBRA) was applied to proton beam therapy to address the problem of lateral density heterogeneity. In the calculation, the phase-space parameters were characterized for multiple range (i.e. proton energy) bins for given pencil beams. The particles that were included in each pencil beam were transported and redefined periodically until they had stopped. The redefined beams formed a detouring path that was different from that of the non-redefined pencil beams, and the path of each redefined beam was straight. The results calculated by the PBRA were compared with measured proton dose distributions in a heterogeneous slab phantom and an anthropomorphic phantom. Through the beam redefinition process, the PBRA was able to predict the measured proton-detouring effects. Therefore, the PBRA may allow improved calculation accuracy when dealing with lateral heterogeneities in proton therapy applications.
- 31 January 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 1169-1184
Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
In proton beam therapy, changes in the proton range due to lateral heterogeneity may cause serious errors in the dose distribution. In the present study, the pencil-beam redefinition algorithm (PBRA) was applied to proton beam therapy to address the problem of lateral density heterogeneity. In the calculation, the phase-space parameters were characterized for multiple range (i.e. proton energy) bins for given pencil beams. The particles that were included in each pencil beam were transported and redefined periodically until they had stopped. The redefined beams formed a detouring path that was different from that of the non-redefined pencil beams, and the path of each redefined beam was straight. The results calculated by the PBRA were compared with measured proton dose distributions in a heterogeneous slab phantom and an anthropomorphic phantom. Through the beam redefinition process, the PBRA was able to predict the measured proton-detouring effects. Therefore, the PBRA may allow improved calculation accuracy when dealing with lateral heterogeneities in proton therapy applications.
- 20 January 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (4) , 965-977
A feasibility study of a molecular-based patient setup verification method using a parallel-plane PET system
A feasibility study of a novel PET-based molecular image guided radiation therapy (m-IGRT) system was conducted by comparing PET-based digitally reconstructed planar image (PDRI) registration with radiographic registration. We selected a pair of opposing parallel-plane PET systems for the practical implementation of this system. Planar images along the in-plane and cross-plane directions were reconstructed from the parallel-plane PET data. The in-plane and cross-plane FWHM of the profile of 2 mm diameter sources was approximately 1.8 and 8.1 mm, respectively. Therefore, only the reconstructed in-plane image from the parallel-plane PET data was used in the PDRI registration. In the image registration, five different sizes of (18)F cylindrical sources (diameter: 8, 12, 16, 24, 32 mm) were used to determine setup errors. The data acquisition times were 1, 3 and 5 min. Image registration was performed by five observers to determine the setup errors from PDRI registration and radiographic registration. The majority of the mean registration errors obtained from the PDRI registration were not significantly different from those obtained from the radiographic registration. Acquisition time did not appear to result in significant differences in the mean registration error. The mean registration error for the PDRI registration was found to be 0.93 ± 0.33 mm. This is not statistically different from the radiographic registration which had a mean registration error of 0.92 ± 0.27 mm. Our results suggest that m-IGRT image registration using PET-based reconstructed planar images along the in-plane direction is feasible for clinical use if PDRI registration is performed at two orthogonal gantry angles.
- 20 January 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (4) , 965-977
A feasibility study of a molecular-based patient setup verification method using a parallel-plane PET system
A feasibility study of a novel PET-based molecular image guided radiation therapy (m-IGRT) system was conducted by comparing PET-based digitally reconstructed planar image (PDRI) registration with radiographic registration. We selected a pair of opposing parallel-plane PET systems for the practical implementation of this system. Planar images along the in-plane and cross-plane directions were reconstructed from the parallel-plane PET data. The in-plane and cross-plane FWHM of the profile of 2 mm diameter sources was approximately 1.8 and 8.1 mm, respectively. Therefore, only the reconstructed in-plane image from the parallel-plane PET data was used in the PDRI registration. In the image registration, five different sizes of (18)F cylindrical sources (diameter: 8, 12, 16, 24, 32 mm) were used to determine setup errors. The data acquisition times were 1, 3 and 5 min. Image registration was performed by five observers to determine the setup errors from PDRI registration and radiographic registration. The majority of the mean registration errors obtained from the PDRI registration were not significantly different from those obtained from the radiographic registration. Acquisition time did not appear to result in significant differences in the mean registration error. The mean registration error for the PDRI registration was found to be 0.93 ± 0.33 mm. This is not statistically different from the radiographic registration which had a mean registration error of 0.92 ± 0.27 mm. Our results suggest that m-IGRT image registration using PET-based reconstructed planar images along the in-plane direction is feasible for clinical use if PDRI registration is performed at two orthogonal gantry angles.
- 29 July 2010
- Published by Wiley in Medical Physics
- Vol. 37 (8) , 4445-4455
Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy
Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation.Methods: Proton therapy using a beam on‐line PET system mounted on a rotating gantry port (BOLPs‐RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs‐RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs‐RGp.Results: The decay curves for measured activity were able to be approximated using two or three half‐life values regardless of the treatment site. The activity of half‐life value of about 2 min was important for a confirmation of the proton irradiated volume.Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs‐RGp. For the monitoring of the proton irradiated volume, the detection of generated in a human body was important.
- 29 July 2010
- Published by Wiley in Medical Physics
- Vol. 37 (8) , 4445-4455
Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy
Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation.Methods: Proton therapy using a beam on‐line PET system mounted on a rotating gantry port (BOLPs‐RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs‐RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs‐RGp.Results: The decay curves for measured activity were able to be approximated using two or three half‐life values regardless of the treatment site. The activity of half‐life value of about 2 min was important for a confirmation of the proton irradiated volume.Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs‐RGp. For the monitoring of the proton irradiated volume, the detection of generated in a human body was important.