Assessment of the systematic errors caused by diffusion gradient inhomogeneity in DTI‐computer simulations
- 25 July 2019
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 32 (11) , e4130
Abstract
Diffusion tensor imaging (DTI) is a powerful MRI modality that allows the investigation of the microstructure of tissues both in vivo and noninvasively. Its reliability is strictly dependent on the performance of diffusion‐sensitizing gradients, of which spatial nonuniformity is a known issue in the case of virtually all clinical MRI scanners.The influence of diffusion gradient inhomogeneity on the accuracy of the diffusion tensor imaging was investigated by means of computer simulations supported by an MRI experiment performed at the isocenter and 15 cm away. The DTI measurements of two diffusion phantoms were simulated assuming a nonuniform diffusion‐sensitizing gradient and various levels of noise. Thereafter, the tensors were calculated by two methods: (i) assuming a spatially constant b‐matrix (standard DTI) and (ii) applying the b‐matrix spatial distribution in the DTI (BSD‐DTI) technique, a method of indicating the b‐matrix for each voxel separately using an anisotropic phantom as a standard of diffusion. The average eigenvalues and fractional anisotropy across the homogeneous region of interest were calculated and compared with the expected values.Diffusion gradient inhomogeneity leads to overestimation of the largest eigenvalue, underestimation of the smallest one and thus overestimation of fractional anisotropy. The effect is similar to that caused by noise; however, it could not be corrected by increasing SNR.The MRI measurements, performed using a 3 T clinical scanner, revealed that the split of the eigenvalues measured 15 cm away from the isocenter is significant (up to 25%). The BSD‐DTI calibration allowed the reduction of the measured fractional anisotropy of the isotropic medium from 0.174 to 0.031, suggesting that gradient inhomogeneity was the main cause of this error. For the phantom measured at the isocenter, however, the split was almost not observed; the average eigenvalues were shifted from the expected value by ~ 5%.Keywords
Funding Information
- Polish Ministry of Science and Higher Education
- National Centre of Research and Development (PBS2/A2/16/2013, STRATEGMED2/265761/10/NCBR/2015)
This publication has 26 references indexed in Scilit:
- The generalized Stejskal-Tanner equation for non-uniform magnetic field gradientsJournal of Magnetic Resonance, 2018
- A macroscopic view of microstructure: Using diffusion-weighted images to infer damage, repair, and plasticity of white matterNeuroscience, 2014
- Clinical Applications of Diffusion Tensor ImagingWorld Neurosurgery, 2014
- Error Propagation Framework for Diffusion Tensor Imaging via Diffusion Tensor RepresentationsIEEE Transactions on Medical Imaging, 2007
- Analytical error propagation in diffusion anisotropy calculationsJournal of Magnetic Resonance Imaging, 2004
- Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imagingMagnetic Resonance in Medicine, 2003
- The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a reviewNMR in Biomedicine, 2002
- Toward a quantitative assessment of diffusion anisotropyMagnetic Resonance in Medicine, 1996
- Microstructural and Physiological Features of Tissues Elucidated by Quantitative-Diffusion-Tensor MRIJournal of Magnetic Resonance, Series B, 1996
- Estimation of the Effective Self-Diffusion Tensor from the NMR Spin EchoJournal of Magnetic Resonance, Series B, 1994