Objective and subjective preoperative refraction techniques for wavefront-optimized and wavefront-guided laser in situ keratomileusis
Authors:
- Bradley J. RandlemanBRBradley J. Randleman
- 1 February 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (2) , 256-259
Abstract
To determine which of 3 methods for measuring preoperative refractive error yields the best refractive outcomes after wavefront-guided (Visx Star S4) or wavefront-optimized (WaveLight Allegretto Wave) excimer laser in situ keratomileusis (LASIK). Emory Eye Center and Emory Vision, Emory University, Atlanta, Georgia, USA. This retrospective analysis of LASIK, performed from June to December 2007, analyzed sphere, cylinder, and spherical equivalent (SE) refractions generated from 3 methods (manifest refraction, aberrometer autorefraction [CustomVue WaveScan], corneal analyzer autorefraction [Nidek ARK-10000 OPD]), actual programmed treatment, and absolute deviation from ideal treatment (deviation) for each technique. In the wavefront-guided group (63 eyes, 33 patients), manifest refraction and aberrometer autorefraction generated similar deviation for sphere and SE; both were significantly better than corneal analyzer autorefraction (P= .02 and P= .03, respectively). Aberrometer autorefraction generated less cylinder deviation than the other methods (both P= .003). In the wavefront-optimized group (61 eyes, 36 patients), manifest refraction generated less deviation for sphere and SE than aberrometer autorefraction or corneal analyzer autorefraction (sphere: P= .005 and P= .009, respectively; SE: P= .005 and P= .002, respectively). Manifest refraction and aberrometer autorefraction cylinder generated similar deviation, while aberrometer autorefraction was less than corneal analyzer autorefraction (P= .041). Overall, manifest refraction was most accurate in generating postoperative emmetropia with both laser treatments; however, aberrometer autorefraction produced the least cylinder deviation for wavefront-guided treatment. Corneal analyzer autorefraction produced the least accurate results with both lasers.Keywords
This publication has 15 references indexed in Scilit:
- The Precision of Wavefront Refraction Compared to Subjective Refraction and AutorefractionOptometry and Vision Science, 2007
- Wavefront Analyzers Induce Instrument MyopiaJournal of Refractive Surgery, 2006
- Retreatment after Wavefront-Guided and Standard Myopic LASIKOphthalmology, 2006
- Accuracy, Repeatability, and Clinical Application of Spherocylindrical Automated Refraction Using Time-Based Wavefront Aberrometry MeasurementsOphthalmology, 2006
- Retreatment of LASIKJournal of Refractive Surgery, 2006
- Autorefraction as an outcome measure of laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2004
- Evaluation of refractive error measurements of the WaveScan WaveFront system and the Tracey Wavefront aberrometerJournal of Cataract & Refractive Surgery, 2003
- Incidence and associations of retreatment after LASIKOphthalmology, 2003
- Laser in situ keratomileusis for myopia and astigmatism: safety and efficacyOphthalmology, 2002
- Comparison of objective and subjective refraction before and after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999