Effect of signal‐to‐noise ratio and spectral linewidth on metabolite quantification at 4 T
Author:
- 4 January 2007
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 20 (5) , 512-521
Abstract
The accuracy and precision of measurements of metabolite concentrations from short echo‐time spectra has previously been characterized at l.5 T as a function of signal‐to‐noise ratio (SNR) and peak linewidth. The purpose of this study was to characterize the systematic error in quantification of metabolite concentrations associated with linewidth and SNR for the major metabolites of interest in the short echo‐time 1H‐MR spectrum at 4 T. Simulated 4 T LASER localized spectra (TE = 46 ms) were generated with full width at half maximum (FWHM) over the range 4–14 Hz, and SNR over the range 5–500 by adding 100 Gaussian‐distributed noise realizations at each combination of SNR and linewidth. Linewidth and SNR were treated as independent parameters, and therefore an increase in linewidth at a constant SNR resulted in increased metabolite areas. All spectra were fitted in the time domain using identical prior‐knowledge and relative parameter starting values. Six metabolites (N‐acetylaspartate, glutamate, creatine, myo‐inositol, glycerophosphocholine, phosphocholine) were quantified with >90% accuracy and 1H‐MRS is sensitive to SNR and linewidth. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 39 references indexed in Scilit:
- In vivo quantitative 1H MRS of cerebellum and evaluation of quantitation reproducibility by simulation of different levels of noise and spectral resolutionMagnetic Resonance Imaging, 2004
- Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifactsNMR in Biomedicine, 2004
- Brain metabolite concentration ratios in vivo: multisite reproducibility by single-voxel 1H MR spectroscopyMagnetic Resonance Imaging, 2004
- Quantitation of simulated short echo time 1H human brain spectra by LCModel and AMARESMagnetic Resonance in Medicine, 2004
- The role of relaxation time corrections for the evaluation of long and short echo time 1H MR spectra of the hippocampus by NUMARIS and LCModel techniquesMagnetic Resonance Materials in Physics, Biology and Medicine, 2003
- High‐resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy‐matched voxel sizesMagnetic Resonance in Medicine, 2003
- Quantitative 1H‐magnetic resonance spectroscopy of human brain: Influence of composition and parameterization of the basis set in linear combination model‐fittingMagnetic Resonance in Medicine, 2002
- Reproducibility of Hippocampal Single-Voxel Proton MR Spectroscopy and Chemical Shift ImagingAmerican Journal of Roentgenology, 2001
- Factors affecting the quantification of short echoin-vivo1H MR spectra: prior knowledge, peak elimination, and filteringNMR in Biomedicine, 1999
- Determination of concentrations by time domain fitting of proton nmr echo signals using prior knowledgeMagnetic Resonance in Medicine, 1992