High‐resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy‐matched voxel sizes
Open Access
- 21 January 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (2) , 299-306
Abstract
In a systematic study on the interdependence of linewidth, signal‐to‐noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging (1H‐SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High‐precision quantitative data (0.75–0.094 cm3) were obtained for all resolutions, enabling the creation of metabolic maps that display details such as the ventricles, sulci, and gyri. High‐resolution 1H‐SI allows differences in metabolic ratios to be estimated for anatomically defined regions in gray (GM) and white matter (WM). Seven distinct regions in a healthy brain were anatomically segmented and their metabolic ratios were compared quantitatively. Data from a tumor patient are also presented to demonstrate potential clinical applications. Because of the high resolution, the metabolite ratios could be determined for distinct pathologic regions within the tumor and its surroundings. The method was additionally applied to a patient with patchy Pelizaeus Merzbacher disease (PMD), and compared to single‐voxel spectroscopy performed in the same session. High‐resolution SI data were demonstrated in our study to allow the direct matching of anatomic and metabolic images. This may enhance the clinical value of 1H‐SI. Magn Reson Med 49:299–306, 2003.Keywords
Funding Information
- Austrian Science Fund (FWF P14715-PSY)
This publication has 22 references indexed in Scilit:
- SNR versus resolution in 3D 1H MRS of the human brain at high magnetic fieldsMagnetic Resonance in Medicine, 2001
- In vivo 1H NMR spectroscopy of the human brain at 7 TMagnetic Resonance in Medicine, 2001
- Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imagingMagnetic Resonance in Medicine, 2000
- Automated spectral analysis III: Application to in Vivo proton MR Spectroscopy and spectroscopic imagingMagnetic Resonance in Medicine, 1998
- High spatial resolution and speed in MRSINMR in Biomedicine, 1997
- 3D localized in vivo1H spectroscopy of human brain by using a hybrid of 1D‐hadamard with 2D‐chemical shift imagingMagnetic Resonance in Medicine, 1997
- Proton magnetic resonance spectroscopy in patients with glial tumors: a multicenter studyJournal of Neurosurgery, 1996
- Automatic, localized in Vivo adjustment of all first‐and second‐order shim coilsMagnetic Resonance in Medicine, 1993
- Elevated Lactate and Alkalosis in Chronic Human Brain Infarction Observed by 1H and 31P MR Spectroscopic ImagingJournal of Cerebral Blood Flow & Metabolism, 1992
- 3D phase encoding 1H spectroscopic imaging of human brainMagnetic Resonance Imaging, 1992