Highly Sensitive Choline Oxidase Enzyme Inhibition Biosensor for Lead Ions Based on Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes
- 19 April 2017
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 29 (7) , 1741-1748
Abstract
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) through cross‐linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at –0.3 V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.Keywords
This publication has 32 references indexed in Scilit:
- Glucose oxidase enzyme inhibition sensors for heavy metals at carbon film electrodes modified with cobalt or copper hexacyanoferrateSensors and Actuators B: Chemical, 2013
- Design of a new hypoxanthine biosensor: xanthine oxidase modified carbon film and multi-walled carbon nanotube/carbon film electrodesAnalytical and Bioanalytical Chemistry, 2012
- Determination of Pb2+ ions by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and nanosilicaJournal of Hazardous Materials, 2010
- Application of functionalised carbon nanotubes immobilised into chitosan films in amperometric enzyme biosensorsSensors and Actuators B: Chemical, 2009
- Lead(II) ion-selective electrode based on polyaminoanthraquinone particles with intrinsic conductivityTalanta, 2009
- Glucose oxidase inhibition in poly(neutral red) mediated enzyme biosensors for heavy metal determinationMicrochimica Acta, 2008
- Determination of heavy metals (Cd, Cr, Cu, Fe, Ni, Pb, Zn) by ICP-OES and their speciation in Algerian Mediterranean Sea sediments after a five-stage sequential extraction procedureEnvironmental Monitoring and Assessment, 2007
- Amperometric Biosensors Based on Choline Oxidase Entrapped in Polyacrylamide MicrogelsElectroanalysis, 2007
- Biosensors for heavy metalsBioMetals, 2005
- Comparative Studies of Immobilized Enzyme Electrodes Based on the Inhibitory Effect of Nicotine on Choline Oxidase and AcetylcholinesteraseAnalytical Letters, 1992