Odon device for instrumental vaginal deliveries: results of a medical device pilot clinical study
Authors:
- for the World Health Organization Odon Device Research GroupFGfor the World Health Organization Odon Device Research Group
- Javier A. SchvartzmanJSJavier A. Schvartzman
- Hugo KrupitzkiHKHugo Krupitzki
- Mario MerialdiMMMario Merialdi
- Ana Pilar BetránABAna Pilar Betrán
- Jennifer RequejoJRJennifer Requejo
- My Huong NguyenMNMy Huong Nguyen
- Effy VayenaEVEffy Vayena
- Angel E. FiorilloAFAngel E. Fiorillo
- Enrique C. GadowEGEnrique C. Gadow
- Francisco M. VizcainoFVFrancisco M. Vizcaino
- Felicitas von PeteryFPFelicitas von Petery
Open Access
- 12 March 2018
- journal article
- research article
- Published by Springer Nature in Reproductive Health
- Vol. 15 (1) , 1-10
Abstract
A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.Keywords
Funding Information
- Saving Lives at Birth partners
This publication has 28 references indexed in Scilit:
- Feasibility and safety study of a new device (Odón device) for assisted vaginal deliveries: study protocolReproductive Health, 2013
- Characteristics Associated With Severe Perineal and Cervical Lacerations During Vaginal DeliveryObstetrics & Gynecology, 2011
- Reducing Intrapartum-Related Neonatal Deaths in Low- and Middle-Income Countries—What Works?Seminars in Perinatology, 2010
- The role of instrumental vaginal delivery in low resource settingsBJOG: An International Journal of Obstetrics & Gynaecology, 2009
- No surgical innovation without evaluation: the IDEAL recommendationsThe Lancet, 2009
- Intrapartum cervical lacerations: characteristics, risk factors, and effects on subsequent pregnanciesAmerican Journal of Obstetrics and Gynecology, 2009
- Prolonged Second Stage of Labor and Risk of Adverse Maternal and Perinatal Outcomes: A Systematic ReviewBirth, 2006
- The disappearing art of instrumental delivery: Time to reverse the trendInternational Journal of Gynecology & Obstetrics, 2005
- Premature discontinuation of clinical trial for reasons not related to efficacy, safety, or feasibilityCommentary: Early discontinuation violates Helsinki principlesBMJ, 2001
- Postpartum colposcopy of the cervix: injury and healingInternational Journal of Gynecology & Obstetrics, 1991