Angel E. Fiorillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Angel E. Fiorillo has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Agustina Mazzoni
Instituto de Efectividad Clínica y Sanitaria (IECS), Buenos Aires, Argentina
1 shared publication - Ahmet Metin Gulmezoglu
UNDP/UNFPA/UNICEF/WHO/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP), Department of Reproductive Health and Research, World Health Organization, Geneva 27, Switzerland
1 shared publication - Ana Pilar Betrán
Department of Sexual and Reproductive Health and Research, World Health Organization, Geneva, Switzerland
1 shared publication - Effy Vayena
Health Ethics and Policy Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
1 shared publication - Enrique C. Gadow
Department of Obstetrics and Gynecology, Centro de Educación Médica e Investigaciones Clínicas “Norberto Quirno” (CEMIC-IUC - CONICET), University Hospital, Buenos Aires, Argentina
1 shared publication - Felicitas von Petery
Department of Obstetrics and Gynecology, Centro de Educación Médica e Investigaciones Clínicas “Norberto Quirno” (CEMIC-IUC - CONICET), University Hospital, Buenos Aires, Argentina
1 shared publication
Latest Publications
- Open Access
- 12 March 2018
- Published by Springer Nature in Reproductive Health
- Vol. 15 (1) , 1-10
Odon device for instrumental vaginal deliveries: results of a medical device pilot clinical study
A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.
- 12 March 2018
- Published by Springer Nature in Reproductive Health
- Vol. 15 (1) , 1-10
Open AccessOdon device for instrumental vaginal deliveries: results of a medical device pilot clinical study
A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.