Total Spherical Aberration of the Cornea in Patients with Cataract
- 1 October 2014
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (10) , 1251-1258
Abstract
Purpose: To investigate the distribution of corneal spherical aberration in patients with cataract using the Pentacam HR. Methods: Consecutive cataract patients were examined using the Pentacam HR high‐resolution rotating Scheimpflug camera (Oculus, Wetzlar, Germany). In one eye of each patient, the root‐mean‐square (RMS) of anterior, posterior, and total corneal spherical aberration Z 4 0 was calculated by ray‐tracing on an area of 6 mm diameter. The Pearson correlation coefficient ( r ) was used to assess correlations between Z 4 0 RMS values and age/total corneal refractive power. The χ 2 test was used to compare the proportion of eyes qualifying for spherically neutral or negatively aspheric (−0.17 and −0.27 μm) intraocular lenses (IOLs) by targeted level of residual spherical aberration. Results: Fifty‐seven men and 92 women were included (mean [±SD] age, 71.73 [±9.12] years). The RMS mean (±SD) values of Z 4 0 were +0.353 (±0.132) μm, −0.121 (±0.034) μm, and +0.328 (±0.132) μm, respectively, for the anterior, posterior, and total cornea. The anterior, posterior, and total Z 4 0 were on average significantly higher (p < 0.001) in women than in men. In both sexes, statistically significant (p < 0.05) age‐related changes were found for the anterior and total Z 4 0 but not for the posterior Z 4 0 (p > 0.05). The total Z 4 0 and total corneal refractive power were significantly correlated in men (p = 0.01) but not in women (p = 0.14). For postoperative targets of 0 ± 0.05/+0.10 ± 0.05 μm residual Z 4 0 , the proportion of eyes that would have qualified for implantation of negatively aspheric IOLs with −0.17 and with −0.27 μm was similar (61.1 and 56.3%, respectively; p = 0.09); significantly fewer eyes (6.7%) would have qualified for implantation of neutrally aspheric IOLs (p > 0.05). Conclusions: Total corneal Z 4 0 measured by Pentacam HR might be higher than that reported in previous studies. In most patients, the implantation of commercially available negatively aspheric IOLs would partially compensate for the positive total corneal Z 4 0 .Keywords
This publication has 32 references indexed in Scilit:
- Corneal Spherical Aberration of Eyes with Cataract in a Japanese PopulationJournal of Refractive Surgery, 2010
- Ethnic differences in higher-order aberrations: Spherical aberration in the South East Asian Chinese eyeJournal of Cataract & Refractive Surgery, 2009
- Corneal topography with Scheimpflug imaging and videokeratography: Comparative study of normal eyesJournal of Cataract & Refractive Surgery, 2009
- Wavefront aberrations, depth of focus, and contrast sensitivity with aspheric and spherical intraocular lenses: Fellow-eye studyJournal of Cataract & Refractive Surgery, 2009
- Analysis of the possible benefits of aspheric intraocular lenses: Review of the literatureJournal of Cataract & Refractive Surgery, 2009
- Spherical Aberration and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses: A Comparative StudyAmerican Journal of Ophthalmology, 2008
- Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Wavefront Analysis and Contrast Sensitivity of Aspheric and Spherical Intraocular Lenses: A Randomized Prospective StudyAmerican Journal of Ophthalmology, 2006
- Age-related changes in corneal and ocular higher-order wavefront aberrationsAmerican Journal of Ophthalmology, 2004
- Improved functional vision with a modified prolate intraocular lensJournal of Cataract & Refractive Surgery, 2004