Ethnic differences in higher-order aberrations: Spherical aberration in the South East Asian Chinese eye
Authors:
- 1 December 2009
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (12) , 2144-2148
Abstract
To determine the distribution of higher-order corneal and ocular aberrations in a healthy refractive surgery population. Island Hospital, Penang, Malaysia. In this prospective observational study, 1 eye of ethnic Chinese refractive surgery patients was evaluated with an Orbscan II corneal topographer and a Zywave Hartmann-Shack aberrometer with a 6.0 mm pupil. Height data were analyzed to derive the higher-order aberrations (HOAs) from the 3rd to 5th Zernike order. The mean spherical equivalent in the 70 eyes evaluated was -6.46 diopters +/- 3.10 (SD). The mean total corneal HOA was 0.574 +/- 0.218 microm (range 0.269 to 1.249 microm) and the mean total ocular HOA, 0.525 +/- 0.354 microm (range 0.138 to 2.145 microm). There was no statistically significant correlation with age. The mean 3rd-order ocular aberration was 0.399 +/- 0.287 microm; the mean 4th-order, 0.297 +/- 0.223 microm; and the mean 5th-order, 0.108 +/- 0.101 microm. Corneal spherical aberration was greater than ocular spherical aberration (mean 0.312 +/- 0.114 microm versus 0.200 +/- 0.170 microm). Multilinear regression showed that the only dependent that predicted ocular spherical aberration was anterior corneal asphericity (r(2) = 0.227, F = 17.95, P<.001). Corneal and ocular aberrations in South East Asian Chinese eyes were significantly greater than that reported in other populations. Population differences in wavefront errors were significant, and this should be noted in patient management.Keywords
This publication has 28 references indexed in Scilit:
- Analysis of the possible benefits of aspheric intraocular lenses: Review of the literatureJournal of Cataract & Refractive Surgery, 2009
- Higher-order aberrations in young refractive surgery candidates in IndiaJournal of Cataract & Refractive Surgery, 2008
- Intraocular lens calculation accuracy limits in normal eyesJournal of Cataract & Refractive Surgery, 2008
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Wavefront aberration and its association with intraocular pressure and central corneal thickness in myopic eyesJournal of Cataract & Refractive Surgery, 2007
- Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Validity of the keratometric index: Large population-based studyJournal of Cataract & Refractive Surgery, 2007
- Relationship between the corneal surface and the anterior segment of the cornea: An Asian perspectiveJournal of Cataract & Refractive Surgery, 2006
- Higher-order aberrations from the internal optics of the eyeJournal of Cataract & Refractive Surgery, 2005
- Influence of Lid Position on AstigmatismOptometry and Vision Science, 1986