Dynamization of locked plating on distal femur fracture
- 8 January 2011
- journal article
- case report
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (4) , 535-539
Abstract
Most of the clinical studies on the results of MIPO (minimally invasive plate osteosynthesis) with the use of anatomically preshaped locking plates for the complex distal femoral fractures have shown favorable results. In the application of bridge plating, placement of lag screws to the butterfly fragments is usually not recommended because it may make the whole construct too stiff. Recently, problems of nonunion related to excessive stiffness after MIPO using a locked plate were reported but the only solution suggested was reoperation with a bone graft. We herein report a case of nonunion after MIPO of the distal femoral fracture where we applied a concept of “dynamization of the plate-bone construct” to make it less stiff and in turn to get fracture healing with bridging callus formation. A 58-year-old woman sustained a simple oblique fracture of the distal femur (AO-OTA 33A1). We performed MIPO procedure using a locking compression plate-distal femur. To get the alignment, we have placed a conventional screw across the fracture line through the dynamic compression unit (DCU) of the combination hole. Postoperative radiographs revealed 7–8 mm gap across the entire fracture surface which was not obvious on the intra-operative C-arm images. Radiographs taken 6 months after operation showed almost no callus formation with shuttle marginal resorption. We interpreted the situation that the construct was too stiff to allow motion across the fracture site due to the lag screw. We thought we have used it as a reduction screw but it acted as a lag screw, preventing motion at the fracture site. Given this analysis, we have only taken the lag screw out to make the construct less stable. It caused the situation of absolute stability with a significant gap to turn into the one of relative stability with acceptable gap. Fracture has solidly healed with bridging callus formation 6 months after lag screw removal under local anesthesia. We would like to call this strategy as “dynamization” of the locked plating.Keywords
This publication has 19 references indexed in Scilit:
- The Current Status of Locked Plating: The Good, the Bad, and the UglyJournal of Orthopaedic Trauma, 2008
- Biomechanical Considerations in Plate Osteosynthesis: The Effect of Plate-to-Bone Compression With and Without Angular Screw StabilityJournal of Orthopaedic Trauma, 2007
- The Evolution of Locked PlatesJournal of Bone and Joint Surgery, 2006
- Biomechanics of Locked Plates and ScrewsJournal of Orthopaedic Trauma, 2004
- Early Results of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur (AO/OTA Types A2, A3, C2, and C3)Journal of Orthopaedic Trauma, 2004
- Failure of Less Invasive Stabilization System Plates in the Distal FemurJournal of Orthopaedic Trauma, 2004
- Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled?Injury, 2003
- Distal Femur Fractures with Complex Articular InvolvementOrthopedic Clinics of North America, 2002
- Comparison of the mechanical performance of three types of external fixators: linear, circular and hybridClinical Biomechanics, 1995
- EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURESThe Lancet, 1986